Colon capsule endoscopy: Detection of colonic polyps compared with conventional colonoscopy and visualization of extracolonic pathologies

被引:25
作者
Hagel, Alexander F. [1 ]
Gaebele, Erwin [2 ]
Raithel, Martin [1 ]
Hagel, Wolfgang H. [1 ]
Albrecht, Heinz [1 ]
de Rossi, Thomas M. [1 ]
Singer, Christine [3 ]
Schneider, Thomas [4 ]
Neurath, Markus F. [1 ]
Farnbacher, Michael J. [4 ]
机构
[1] Univ Erlangen Nurnberg, Dept Gastroenterol, Erlangen, Germany
[2] Asklepios Clin Burglengenfeld, Dept Gastroenterol, Burglengenfeld, England
[3] Inst Employment Res, Nurnberg, Germany
[4] Univ Erlangen Nurnberg, Teaching Hosp, Clin Ctr Fuerth, Dept Gastroenterol, Erlangen, Germany
关键词
Cancer prevention; Capsule endoscopy; Colon; Colonoscopy; Colorectal cancer; PILLCAM COLON; COST-EFFECTIVENESS; CANCER; MULTICENTER;
D O I
10.1155/2014/691785
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND: Conventional colonoscopy (CC) is the gold standard for diagnostic examination of the colon. However, the overall acceptance of this procedure is low due to patient fears of complications or embarrassment. Colon capsule endoscopy (CCE) represents a minimally invasive, patient-friendly procedure that offers complete visualization of the entire intestine. OBJECTIVE: To assess the PillCam Colon 2 (Given Imaging Ltd, Israel) capsule with regard to feasibility, sensitivity and specificity for the detection of colonic pathologies and additional recorded extracolonic findings. METHODS: CCE was performed before CC in patients indicated for CC for known or suspected colonic disease. The results of both techniques were compared with regard to polyp detection. Additionally, bowel preparation and extracolonic pathologies were analyzed. RESULTS: Twenty-four patients (mean age 51.1 years) were included in the analysis. Visualization of the colon was complete in 23 CCs and 17 CCEs. No adverse events or major technical failures occurred. CC detected 47 polyps and CCE detected 43 polyps of any size (per-finding sensitivity 90.9%, specificity 67.6%). The accuracy of CCE in detecting polyp carriers was 81.5% (per-patient analysis). On average, the colon was adequately cleansed in 90.1% of patients. CCE identified esophageal, gastric and small bowel pathologies in seven (24%), nine (38%) and 14 (58%) patients, respectively. CONCLUSIONS: CCE proved to be technically feasible and safe. Acceptable sensitivity and moderate specificity levels in polyp detection were recorded. Bowel preparation was adequate in most patients. Because extracolonic pathologies were effectively visualized, new indications for the PillCam Colon 2 may be defined.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 24 条
[1]  
Adler Samuel N, 2011, Therap Adv Gastroenterol, V4, P265, DOI 10.1177/1756283X11401645
[2]   Once-only flexible sigmoidoscopy screening in prevention of colorectal cancer: a multicentre randomised controlled trial [J].
Atkin, Wendy S. ;
Edwards, Rob ;
Kralj-Hans, Ines ;
Wooldrage, Kate ;
Hart, Andrew R. ;
Northover, John M. A. ;
Parkin, D. Max ;
Wardle, Jane ;
Duffy, Stephen W. ;
Cuzick, Jack .
LANCET, 2010, 375 (9726) :1624-1633
[3]   Protection From Right- and Left-Sided Colorectal Neoplasms After Colonoscopy: Population-Based Study [J].
Brenner, Hermann ;
Hoffmeister, Michael ;
Arndt, Volker ;
Stegmaier, Christa ;
Altenhofen, Lutz ;
Haug, Ulrike .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2010, 102 (02) :89-95
[4]   Magnetically Controllable Gastrointestinal Steering of Video Capsules [J].
Carpi, Federico ;
Kastelein, Nathan ;
Talcott, Michael ;
Pappone, Carlo .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (02) :231-234
[5]   Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy [J].
Eliakim, R. ;
Yassin, K. ;
Niv, Y. ;
Metzger, Y. ;
Lachter, J. ;
Gal, E. ;
Sapoznikov, B. ;
Konikoff, F. ;
Leichtmann, G. ;
Fireman, Z. ;
Kopelman, Y. ;
Adler, S. N. .
ENDOSCOPY, 2009, 41 (12) :1026-1031
[6]   Detecting esophageal disease with second-generation capsule endoscopy: initial evaluation of the PillCam ESO 2 [J].
Gralnek, I. M. ;
Adler, S. N. ;
Yassin, K. ;
Koslowsky, B. ;
Metzger, Y. ;
Elialkim, R. .
ENDOSCOPY, 2008, 40 (04) :275-279
[7]   Capsule colonoscopy increases uptake of colorectal cancer screening [J].
Groth, Stefan ;
Krause, Horst ;
Behrendt, Rainer ;
Hill, Helge ;
Boerner, Michael ;
Bastuerk, Murat ;
Plathner, Nora ;
Schuette, Friedrich ;
Gauger, Ulrich ;
Riemann, Juergen Ferdinand ;
Altenhofen, Lutz ;
Roesch, Thomas .
BMC GASTROENTEROLOGY, 2012, 12
[8]   Cost-effectiveness of capsule endoscopy in screening for colorectal cancer [J].
Hassan, C. ;
Zullo, A. ;
Winn, S. ;
Morini, S. .
ENDOSCOPY, 2008, 40 (05) :414-421
[9]   PROSPECTIVE BLINDED TRIAL OF THE COLONOSCOPIC MISS-RATE OF LARGE COLORECTAL POLYPS [J].
HIXSON, LJ ;
FENNERTY, MB ;
SAMPLINER, RE ;
GAREWAL, HS .
GASTROINTESTINAL ENDOSCOPY, 1991, 37 (02) :125-127
[10]  
Knöpnadel J, 2003, INTERNIST, V44, P268, DOI 10.1007/s00108-002-0793-4