System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction

被引:7
作者
Uchiyama, Takanori [1 ]
Sakai, Hiroaki [2 ]
机构
[1] Keio Univ, Fac Sci & Technol, Dept Appl Phys & Physicoinformat, Kohoku Ku, Yokohama, Kanagawa 223, Japan
[2] Keio Univ, Grad Sch Sci & Technol, Yokohama, Kanagawa 223, Japan
关键词
Mechanomyogram; System identification; Abductor pollicis brevis muscle; Acceleration; Displacement; FREQUENCY-RESPONSE; SKELETAL-MUSCLE; JOINT UNIT; MODEL; SIGNAL;
D O I
10.1007/s11517-013-1107-9
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The MMGs were detected with either a capacitor microphone or an acceleration sensor. The transfer functions between stimulation and the MMG and between stimulation and torque were identified by the singular value decomposition method. The torque and the MMG, which were detected with a capacitor microphone, DMMG, were approximated with a second- and a third-order model, respectively. The natural frequency of the torque, reflecting longitudinal mechanical characteristics, did not show a significant difference from that of the DMMG. The MMG detected with an acceleration sensor was approximated with a fourth-order model. The natural frequencies of the AMMG reflecting the muscle and subcutaneous tissue in the transverse direction were obtained. Both DMMG and AMMG have to be measured to investigate the model of the MMG system for parallel-fibered muscle. The MMG system of parallel-fibered muscle was also modeled with a sixth-order model.
引用
收藏
页码:1349 / 1355
页数:7
相关论文
共 19 条
[1]  
Alexander RMcN, 1975, J HUM MOVEMENT STUD, V222, P426
[2]   THE DYNAMIC-RESPONSE MODEL OF 9 DIFFERENT SKELETAL-MUSCLES [J].
BARATTA, R ;
SOLOMONOW, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (03) :243-251
[3]   Frequency domain-based models of skeletal muscle [J].
Baratta, RV ;
Solomonow, M ;
Zhou, BH .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (02) :79-91
[4]   FREQUENCY-RESPONSE OF HUMAN SOLEUS MUSCLE [J].
BAWA, P ;
STEIN, RB .
JOURNAL OF NEUROPHYSIOLOGY, 1976, 39 (04) :788-793
[5]   PHYSIOLOGICAL CROSS-SECTIONAL AREA OF HUMAN LEG MUSCLES BASED ON MAGNETIC-RESONANCE-IMAGING [J].
FUKUNAGA, T ;
ROY, RR ;
SHELLOCK, FG ;
HODGSON, JA ;
DAY, MK ;
LEE, PL ;
KWONGFU, H ;
EDGERTON, VR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (06) :926-934
[6]  
Gray H, 1995, GRAYS ANATOMY ANATOM, P783
[7]   Measurement of muscle contraction with ultrasound imaging [J].
Hodges, PW ;
Pengel, LHM ;
Herbert, RD ;
Gandevia, SC .
MUSCLE & NERVE, 2003, 27 (06) :682-692
[8]  
Irie T., 1992, Transactions of the Institute of Electronics, Information and Communication Engineers D-II, VJ75D-II, P947
[9]   Frequency response model of skeletal muscle and its association with contractile properties of skeletal muscle [J].
Itoh, Yasushi ;
Akataki, Kumi ;
Mita, Katsumi ;
Watakabe, Makoto ;
Nonaka, Hisako .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2013, 23 (03) :572-579
[10]   ARCHITECTURAL DESIGN OF THE HUMAN INTRINSIC HAND MUSCLES [J].
JACOBSON, MD ;
RAAB, R ;
FAZELI, BM ;
ABRAMS, RA ;
BOTTE, MJ ;
LIEBER, RL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (05) :804-809