Equivalent Circuit Models of Cell and Array for Resonant Cavity-Based Piezoelectric Micromachined Ultrasonic Transducer

被引:21
作者
Xu, Tingzhong [1 ,2 ]
Zhao, Libo [1 ]
Jiang, Zhuangde [1 ]
Guo, Shuaishuai [1 ]
Li, Zhikang [1 ]
Yang, Ping [1 ]
Luo, Guoxi [1 ]
Sun, Lin [1 ]
Zhang, Liangchi [2 ]
机构
[1] Xi An Jiao Tong Univ, Int Joint Lab Micro Nano Mfg & Measurement Techno, Collaborat Innovat Ctr Suzhou Nano Sci & Technol, State Key Lab Mfg Syst Engn,Sch Mech Engn, Xian 710049, Peoples R China
[2] Univ New South Wales, Sch Mech & Mfg Engn, Kensington, NSW 2052, Australia
基金
澳大利亚研究理事会; 中国国家自然科学基金;
关键词
Acoustics; Cavity resonators; Neck; Liquids; Integrated circuit modeling; Electron tubes; Ultrasonic transducers; Array; high emission performance; liquid amplification effect; piezoelectric micromachined ultrasonic transducers (PMUTs); resonant cavity; THEORETICAL-MODEL; SOUND;
D O I
10.1109/TUFFC.2020.2993805
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This article presents a design of resonant cavity-based piezoelectric micromachined ultrasonic transducers (PMUTs), including impedance matching tube-integrated (T) and Helmholtz resonant (HR) cavity-integrated PMUTs. In addition, equivalent circuit models for single PMUT cell and PMUT array are developed for structural optimization and complex array design. The model-derived results agree well with the FEM results. On the basis of the proposed models, an optimized design is established to achieve high output pressure and a good array working performance. The working performance of arrays that consist of HR-PMUTs and traditional circular diaphragm PMUTs (C-PMUTs) is compared. Results indicate that the HR-PMUT array has a lower crosstalk effect than the traditional C-PMUT array. Furthermore, the highest ultrasonic output pressure of HR-PMUT array at the resonant frequency can be achieved with an increase of up to 163% compared with that of the C-PMUT array because of the liquid amplification effect. Also, the cavity-based design and its model can be used for further advanced PMUT cell structures in other arrays to improve their performance.
引用
收藏
页码:2103 / 2118
页数:16
相关论文
共 15 条
[11]   Bi-Stable Aluminum Nitride-Based Piezoelectric Micromachined Ultrasonic Transducer (PMUT) [J].
Schneider, Michael ;
Dorfmeister, Manuel ;
Moll, Philipp ;
Kaltenbacher, Manfred ;
Schmid, Ulrich .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2020, 29 (05) :948-953
[12]   JMEMS Letters.1pt Equidimensional Piezoelectric Micromachined Ultrasonic Transducer Array With Synchronously Improved Bandwidth and Sensitivity [J].
Xu, Xingli ;
Gong, Yuewu ;
Wang, Zhuochen ;
Ma, Yongquan ;
Yu, Chenyang ;
Wei, Wei ;
Niu, Pengfei ;
Pang, Wei .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2024, 33 (05) :511-513
[13]   PZT-Film-Based Piezoelectric Micromachined Ultrasonic Transducer with I-Shaped Composite Diaphragm [J].
Yu, Qing ;
Fan, Guoxiang ;
Ren, Wei ;
Fan, Qingqing ;
Ti, Jinming ;
Li, Junhong ;
Wang, Chenghao .
MICROMACHINES, 2022, 13 (10)
[14]   High Round-Trip Gain Piezoelectric-Capacitive Hybrid Micromachined Ultrasonic Transducer Based on Anodic Bonding Technology [J].
Wang, Yan ;
Xu, Weijiang ;
Lv, Ning ;
Wu, Tao ;
Zhou, Jia ;
Ren, Junyan .
IEEE SENSORS JOURNAL, 2025, 25 (09) :14842-14849
[15]   Cantilever beam-based piezoelectric micromachined ultrasonic transducer with post processing soft interconnecting strategy for in-air rangefinding [J].
Wang, Yan ;
Chen, Peng ;
Zhang, Junning ;
Li, Zihan ;
Yu, Hongbin .
MICROSYSTEMS & NANOENGINEERING, 2025, 11 (01)