Visual performance after toric IOL implantation in patients with corneal astigmatism

被引:9
|
作者
Bett Correia, Renato Jose [1 ]
Moreira, Hamilton [1 ]
Lago Netto, Solon Uchoa [1 ]
Pantaleao, Gleisson Rezende [1 ]
机构
[1] Hosp Olhos Parana, Curitiba, Parana, Brazil
关键词
Astigmatism/surgery; Lens implantation; intraocular/methods; Phacoemulsification; Cataract extraction; Visual acuity; Postoperative complications; INTRAOCULAR-LENS IMPLANTATION;
D O I
10.1590/S0004-27492009000500007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze visual acuity without correction and rotational stability outcomes following toric IOL implantation. Methods: Prospective study of 20 eyes of 13 patients that underwent phacoemulsification surgery indicated for cataract associated with regular keratomeric astigmatism, symmetrical, ranging from 1 to 4 diopters. Best corrected visual acuity, refraction, keratometry and computed topography were performed preoperatively. The calculation of cylindrical lens power and its placement were determined by the manufacturer. All lenses were implanted in the capsular bag by the same surgeon. The patients were examined by a second independent observer, at 1(st), 10(th), 20(th), 30(th), and 60(th) postoperative day. Results: Visual acuity without correction ranged between 20/15 and 20/40. One eye achieved 20/15 (5%), 4 eyes 20/20 (20%), 6 eyes 20/25 (30%), 7 eyes 20/30 (35%) and 2 eyes 20/40 (10%). Best corrected visual acuity ranged between 20/15 and 20/40; two eyes with 20/15 (10%), 9 eyes 20/20 (45%), 7 eyes 20/25 (35%), 1 eye 20/30 (5%) and 1 eye 20/40 (5%). It is important to remember that the average spherical refraction was -0.05 SD (ranging from -0.50 to + 0.75 SD). The mean cylindrical refraction was -0.63 CD ranging from -0.50 to -1.25 CD. The IOL rotation in this study had an average of 3.2 degrees to 30 degrees, ranging from 0 degrees of rotation to a maximum of 13 degrees; 7 lenses (35%) suffered no rotation, 9 lenses (45%) suffered rotation between 1 degrees to 5 degrees, 3 lenses (15%) had rotation between 6 degrees to 10 degrees, and ultimately 1 lens (5%) had rotation between 11 degrees to 15 degrees. There was no significant rotation after the 30(th) postoperative day. Discussion: The average of rotation of the IOL was 3.2 degrees, where 95% of IOLs presented rotation less than or equal to 10 degrees what means a very good rotational stability. In daily practice, a good visual acuity is directly related to IOL rotational stability and refractive predictability.
引用
收藏
页码:636 / 640
页数:5
相关论文
共 50 条
  • [31] CATARACT SURGERY SURPRISES AFTER TORIC IOL IMPLANTATION
    Alpins, Noel
    Stamatelatos, George
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 : 41 - 41
  • [32] Clinical outcomes of Zeiss toric intraocular lens implantation for correction of corneal astigmatism after cataract
    Kamel, K.
    Dervan, E.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S14 - S14
  • [33] Patients with astigmatism who underwent cataract surgery by phacoemulsification: toric IOL x asferic IOL?
    Torres Netto, Emilio de Almeida
    Gulin, Marina Carvalho
    Zapparoli, Marcio
    Moreira, Hamilton
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2013, 76 (04) : 233 - 236
  • [34] Influence of posterior corneal astigmatism on the outcomes of toric intraocular lens implantation in eyes with oblique astigmatism
    Shinichiro Nakano
    Masaharu Iida
    Yumi Hasegawa
    Takahiro Hiraoka
    Tetsuro Oshika
    Japanese Journal of Ophthalmology, 2021, 65 : 288 - 294
  • [35] Residual astigmatism after toric intraocular lens implantation
    Berdahl, John P.
    Hardten, David R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04): : 730 - 731
  • [36] Influence of posterior corneal astigmatism on the outcomes of toric intraocular lens implantation in eyes with oblique astigmatism
    Nakano, Shinichiro
    Iida, Masaharu
    Hasegawa, Yumi
    Hiraoka, Takahiro
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (02) : 288 - 294
  • [37] Vector Analysis, Rotational Stability, and Visual Outcome After Implantation of a New Aspheric Toric IOL
    Bachernegg, Alexander
    Rueckl, Theresa
    Strohmaier, Clemens
    Jell, Gerlinde
    Grabner, Guenther
    Dexl, Alois K.
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (08) : 513 - 520
  • [38] Astigmatism Tolerance and Visual Outcomes After Bilateral Implantation of a Hybrid Continuous Transitional Focus IOL
    Pedrotti, Emilio
    Bonacci, Erika
    Alio del Barrio, Jorge L.
    Longo, Rosa
    Pagnacco, Camilla
    Marchini, Giorgio
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (01) : 33 - +
  • [39] Visual outcome after phacoemulsification and IOL implantation in diabetic patients
    Zaczek, A
    Olivestedt, G
    Zetterström, C
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (09) : 1036 - 1041
  • [40] Femtosecond Laser-assisted Arcuate Keratotomy Versus Toric IOL Implantation for Correcting Astigmatism
    Yoo, Aeri
    Yun, Samyoung
    Kim, Jae Yong
    Kim, Myoung Joon
    Tchah, Hungwon
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (09) : 574 - 578