Microincisional cataract surgery (MICS) with pulse and burst modes

被引:17
作者
Baykara, M. [1 ]
Ercan, I.
Ozcetin, H.
机构
[1] Uludag Univ, Fac Med, Dept Ophthalmol, TR-16059 Bursa, Turkey
[2] Uludag Univ, Fac Med, Dept Stat, TR-16059 Bursa, Turkey
关键词
ultrasound energy; balanced solution; bimanual cataract surgery; phacoemulsification;
D O I
10.1177/112067210601600604
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare the amount of ultrasound (US) energy and balanced solution (BS) required for burst mode and pulse mode during bimanual phacoemulsification surgery. METHODS. One hundred cases were divided into two groups (the pulse mode Group 1 [50 eyes], the burst mode Group 2 [50 eyes]). One surgeon (M.B.) performed phacoemulsification procedures using topical anesthesia with the AMO Sovereign in all patients. The technique was based on the nuclear hardness and surgeon's criteria and performed bimanually. The surgery time, total ultrasound time (UST) and effective US power (USP), and used balanced solution (BS) were retrospectively compared. RESULTS. The mean surgery time, mean UST, and mean used BS volume were not statistically different in both groups (p > 0.05). The mean EPT was statistically highly different in both groups (p > 0.001). There was a slight tendency toward more surgery time in Group 2 than in Group 1, although the difference was not significant (p=0.146). Statistically significant higher results (Group 1: r=0, 889, p < 0.001 and Group 2: r=0, 834, p < 0.001) were seen in Group 1 when both groups were evaluated for the surgery time and used BS volume. When UST and used BS volume were evaluated in Groups 1 and 2, significant relation was seen in both but the correlation is statistically higher in Group 1 (Group 1: r=0, 765, p < 0.001, and Group 2: r=0,544, p < 0.001). CONCLUSIONS. The very low energy modes with the WhiteStar technology are suitable for bimanual cataract surgery.
引用
收藏
页码:804 / 808
页数:5
相关论文
共 13 条
[1]  
AGARWAL S, 2000, PHACOEMULSIFICATION, P624
[2]   Outcomes of microincision cataract surgery versus coaxial phacoemulsification [J].
Alió, J ;
Rodríguez-Prats, JL ;
Galal, A ;
Ramzy, M .
OPHTHALMOLOGY, 2005, 112 (11) :1997-2003
[3]  
[Anonymous], CATARACT
[4]   USING AN ANTERIOR-CHAMBER MAINTAINER TO CONTROL INTRAOCULAR-PRESSURE DURING PHACOEMULSIFICATION [J].
BLUMENTHAL, M ;
ASSIA, EI ;
CHEN, V ;
AVNI, I .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01) :93-96
[6]   Efficacy and wound-temperature gradient of WhiteStar phacoemulsification through a 1.2 mm incision [J].
Donnenfeld, ED ;
Olson, RJ ;
Solomon, R ;
Finger, PT ;
Biser, SA ;
Perry, HD ;
Doshi, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (06) :1097-1100
[7]   New phacoemulsification technologies [J].
Fine, IH ;
Packer, M ;
Hoffman, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (06) :1054-1060
[8]   Use of power modulations in phacoemulsification - Choo-choo chop and flip phacoemulsification [J].
Fine, IH ;
Packer, M ;
Hoffman, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02) :188-197
[9]  
Hoffman Richard S, 2005, Curr Opin Ophthalmol, V16, P38, DOI 10.1097/00055735-200502000-00007
[10]  
Nagahara A., 1993, PHACOCHOP TECHNIQUE, P12