Some successful approaches to quantitative mineral analysis as revealed by the 3rd Reynolds Cup contest

被引:179
作者
Omotoso, Oladipo [1 ]
Mccarty, Douglas K.
Hillier, Stephen
Kleeberg, Reinhard
机构
[1] Nat Resources Canada, CANMET, Energy Technol Ctr, Devon, AB T9G 1A8, Canada
[2] Chevron ETC, Houston, TX 77042 USA
[3] Macaulay Inst, Aberdeen AB15 8QH, Scotland
[4] TU Bergakad Freiberg, Inst Mineral, D-09596 Freiberg, Germany
关键词
clay minerals; pure reference minerals; quantitative analysis; reference intensity; ratio; Reynolds Cup; Rietveld; the Clay Minerals Society; whole-pattern fitting;
D O I
10.1346/CCMN.2006.0540609
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Details of the quantitative techniques successfully applied to artificial rock mixtures distributed for the third Clay Minerals Society Reynolds Cup (RC) contest are presented. Participants each received three samples, two containing 17 minerals each and a third containing ten minerals. The true composition of the samples was unknown to all participants during the contest period. The results submitted were ranked by summing the deviations from the actual compositions (bias). The top three finishers used mainly X-ray diffraction (XRD) for identification and quantification. The winner obtained an average bias of 11.3% per sample by using an internal standard and modified single-line reference intensity ratio (RIR) method based on pure mineral standards. Full-pattern fitting by genetic algorithm was used to measure the integrated intensity of the diagnostic single-line reflections chosen for quantification. Elemental-composition optimization was used separately to constrain phase concentrations that were uncertain because the reference mineral standards were lacking or not ideal. Cation exchange capacity, oriented-sample XRD analysis, and thermogravimetric analysis were also used as supplementary techniques. The second-place finisher obtained an average bias of 13.9%, also by using an RIR method, but without an added internal standard and with intensity measured by whole-pattern fitting. The third-place finisher, who obtained an average bias of 15.3%, used the Rietveld method for quantification and identification of minor phases (using difference plots). This participant also used scanning electron microscopy (with X-ray microanalysis) to identify minor components and verify the composition of structures used in Rietveld analysis. As in the previous contests, successful quantification appears to be more dependent on analyst experience than on the analytical technique or software used.
引用
收藏
页码:748 / 760
页数:13
相关论文
共 19 条
[1]  
[Anonymous], 2003, 0378 US GEOL SURV
[2]   Rietveld analysis of disordered layer silicates [J].
Bergmann, J ;
Kleeberg, R .
EPDIC 5, PTS 1 AND 2, 1998, 278-2 :300-305
[3]  
BISH DL, 1993, AM MINERAL, V78, P932
[4]   FULLPAT:: a full-pattern quantitative analysis program for X-ray powder diffraction using measured and calculated patterns [J].
Chipera, SJ ;
Bish, DL .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2002, 35 :744-749
[5]   QUANTITATIVE INTERPRETATION OF X-RAY-DIFFRACTION PATTERNS OF MIXTURES .2. ADIABATIC PRINCIPLE OF X-RAY-DIFFRACTION ANALYSIS OF MIXTURES [J].
CHUNG, FH .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1974, 7 (DEC1) :526-531
[6]   QUANTITATIVE INTERPRETATION OF X-RAY-DIFFRACTION PATTERNS OF MIXTURES .1. MATRIX-FLUSHING METHOD FOR QUANTITATIVE MULTICOMPONENT ANALYSIS [J].
CHUNG, FH .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1974, 7 (DEC1) :519-525
[7]  
EBERL DD, 1987, AM MINERAL, V72, P914
[8]   Use of an air brush to spray dry samples for X-ray powder diffraction [J].
Hillier, S .
CLAY MINERALS, 1999, 34 (01) :127-135
[9]  
HILLIER S, 2003, SP PUBL INT, P213, DOI DOI 10.1002/9781444304336.CH11
[10]  
Hillier S., 2002, IUCR COMMISSION POWD, V27, P7