Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock

被引:94
作者
Varpula, Marjut [1 ]
Karlsson, Sari [1 ]
Ruokonen, Esko [1 ]
Pettila, Ville [1 ]
机构
[1] Helsinki Univ Hosp, Helsinki 00029, Finland
关键词
sepsis; septic shock; hemodynamic monitoring; outcome;
D O I
10.1007/s00134-006-0270-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Central venous oxygen saturation (ScvO(2)) in initial resuscitation is included in the Surviving Sepsis Campaign guidelines. ScvO(2) monitoring has also been suggested to be comparable to mixed venous oxygen saturation (SvO(2)) for clinical purposes. The aim of our study was to assess the correlation and agreement of ScvO(2) and SvO(2) and compare ScvO(2)-SvO(2) difference to lactate, oxygen-derived and hemodynamic parameters in early septic shock in ICU after initial resuscitation. Design and setting: Prospective clinical study with 16 patients with septic shock at two university hospital ICUs. A dose of norepinephrine over 0.1 mu g/kg/min was required for inclusion. Measurements and results: Five paired ScvO(2) and SvO(2) samples at 6-h intervals, altogether 72 samples, were collected during 24 h. The mean SvO(2) was below the mean ScvO(2) at all time points. Bias of difference was 4.2% and 95% limits of agreement ranged from -8.1% to 16.5%. The difference correlated significantly to CI and DO2. Conclusions: The difference between paired ScvO(2) and SvO(2) varies highly. Therefore, SvO(2) may not be estimated on the basis of ScvO(2) in treatment of septic shock after resuscitation period in ICU.
引用
收藏
页码:1336 / 1343
页数:8
相关论文
共 50 条
  • [21] Changes of central venous oxygen saturation define fluid responsiveness in patients with septic shock: A prospective observational study
    Xu, Biao
    Yang, Xiaobo
    Wang, Chunyao
    Jiang, Wei
    Weng, Li
    Hu, Xiaoyun
    Peng, Jinmin
    Du, Bin
    JOURNAL OF CRITICAL CARE, 2017, 38 : 13 - 19
  • [22] Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock
    Mozina, Hugo
    Podbregar, Matej
    CRITICAL CARE, 2010, 14 (02):
  • [23] Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock
    Hugo Možina
    Matej Podbregar
    Critical Care, 14
  • [24] Central Venous Oxygen Saturation: Not Easily Replaced
    Nguyen, H. Bryant
    CRITICAL CARE MEDICINE, 2013, 41 (06) : 1570 - 1571
  • [25] Prospective evaluation of regional oxygen saturation to estimate central venous saturation in sepsis
    Koch, Christian
    Roehrig, Rainer
    Monz, Tobias
    Hecker, Andreas
    Uhle, Florian
    Schneck, Emanuel
    Weigand, Markus A.
    Lichtenstern, Christoph
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (04) : 443 - 453
  • [26] Can Mixed Venous Hemoglobin Oxygen Saturation Be Estimated Using a NICO Monitor?
    Kotake, Yoshifumi
    Yamada, Takashige
    Nagata, Hiromasa
    Suzuki, Takeshi
    Takeda, Junzo
    ANESTHESIA AND ANALGESIA, 2009, 109 (01) : 119 - 123
  • [27] Six-hour central venous oxygen saturation has no prognostic value in patients with septic shock
    KM Yoo
    KS Kim
    GJ Suh
    WY Kwon
    JS Kim
    MJ Park
    YJ Choi
    K Kim
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [28] High central venous oxygen saturation is associated with mitochondrial dysfunction in septic shock: A prospective observational study
    Wittayachamnankul, Borwon
    Apaijai, Nattayaporn
    Sutham, Krongkarn
    Chenthanakij, Boriboon
    Liwsrisakun, Chalerm
    Jaiwongkam, Thidarat
    Chattipakorn, Siriporn C.
    Chattipakorn, Nipon
    JOURNAL OF CELLULAR AND MOLECULAR MEDICINE, 2020, 24 (11) : 6485 - 6494
  • [29] Thenar oxygen saturation measured by near infrared spectroscopy as a noninvasive predictor of low central venous oxygen saturation in septic patients
    Mesquida, Jaume
    Masip, Jordi
    Gili, Gisela
    Artigas, Antoni
    Baigorri, Francisco
    INTENSIVE CARE MEDICINE, 2009, 35 (06) : 1106 - 1109
  • [30] Thenar oxygen saturation measured by near infrared spectroscopy as a noninvasive predictor of low central venous oxygen saturation in septic patients
    Jaume Mesquida
    Jordi Masip
    Gisela Gili
    Antoni Artigas
    Francisco Baigorri
    Intensive Care Medicine, 2009, 35