Effective dose conversion coefficient for gamma ray exposure from an overhead plume

被引:1
作者
Dey, Riya [1 ,3 ]
Patni, H. K. [2 ]
Singh, Kapil Deo [1 ]
Kulkarni, M. S. [1 ,3 ]
Anand, S. [1 ,3 ]
机构
[1] Bhabha Atom Res Ctr, Hlth Phys Div, Mumbai, Maharashtra, India
[2] Bhabha Atom Res Ctr, Radiat Safety & Syst Div, Mumbai, Maharashtra, India
[3] Homi Bhabha Natl Inst BARC, Mumbai, Maharashtra, India
关键词
Monte Carlo; voxel phantom; plume; effective dose; FLUKA; external exposure; IMMERSION; HUMANS; ADULTS; CLOUD; MODEL;
D O I
10.1088/1361-6560/ab2c92
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The external radiation exposure from an overhead plume containing gamma emitting radionuclides can contribute substantial dose to the ground receptor during normal operations as well as accidental release conditions of nuclear facilities. In order to estimate the effective dose conversion coefficients (DCCs) directly, a finite plume Monte Carlo model along with the reference phantom at the ground receptor location needs to be implemented. In the present study, a comprehensive simulation of radiation transport from the Gaussian plume source to the ICRP reference adult voxel phantoms (receptor) is carried out using the FLUKA Monte Carlo code. The organ absorbed doses as well as the effective DCCs of the adult reference phantom are computed for different meteorological parameters and downwind distances. To illustrate the application of this model, an overhead Gaussian plume containing two different gamma emitting radionuclides, Xe-135 and Ar-41 are considered. From these simulations, the ratio of the effective dose rate to the kerma rate are estimated as 0.6 SvGy(-1) and 0.65 SvGy(-1) for the exposure from Xe-135 and Ar-41, respectively. This ratio is constant irrespective of the meteorological conditions and cloud models. Further results show that the effective DCCs as a function of the downwind distance vary by an order of magnitude for an unstable weather category; however, the variations are very small in the case of a stable category. This study demonstrates an accurate method for calculating the effective dose to the ground receptor from an external plume which can be further applied for any radionuclide under any meteorological condition.
引用
收藏
页数:10
相关论文
共 32 条
[1]  
[Anonymous], 1996, Ann ICRP, V26, P1
[2]   EFFECTIVE DOSE RATE COEFFICIENTS FOR IMMERSIONS IN RADIOACTIVE AIR AND WATER (vol 174, pg 275, 2017) [J].
Bellamy, M. B. ;
Veinot, K. G. ;
Hiller, M. M. ;
Dewji, S. A. ;
Eckerman, K. F. ;
Easterly, C. E. ;
Hertel, N. E. ;
Leggett, R. W. ;
Manger, R. .
RADIATION PROTECTION DOSIMETRY, 2018, 181 (02) :179-179
[3]   The FLUKA Code: Developments and Challenges for High Energy and Medical Applications [J].
Boehlen, T. T. ;
Cerutti, F. ;
Chin, M. P. W. ;
Fosso, A. ;
Ferrari, A. ;
Ortega, P. G. ;
Mairani, A. ;
Sala, P. R. ;
Smirnov, G. ;
Vlachoudisl, V. .
NUCLEAR DATA SHEETS, 2014, 120 :211-214
[4]   ABSORBED GAMMA DOSE-RATE FOR IMMERSION IN A SEMI-INFINITE RADIOACTIVE CLOUD [J].
DILLMAN, LT .
HEALTH PHYSICS, 1974, 27 (06) :571-580
[5]  
DOE, 1988, DOEEH0070, DOI [10.2172/6953527, DOI 10.2172/6953527]
[6]  
Eckerman K. F., 1993, EPA402R93081 OAK RID
[7]   DERIVATIONS OF CONTINUOUS-FUNCTIONS FOR LATERAL AND VERTICAL ATMOSPHERIC DISPERSION COEFFICIENTS [J].
EIMUTIS, EC ;
KONICEK, MG .
ATMOSPHERIC ENVIRONMENT, 1972, 6 (11) :859-&
[8]   AN IMPROVED MULTIPLE-SCATTERING MODEL FOR CHARGED-PARTICLE TRANSPORT [J].
FERRARI, A ;
SALA, PR ;
GUARALDI, R ;
PADOANI, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 71 (04) :412-426
[9]  
Ferrari A, 2005, 200510INFNTC0511 CER
[10]  
GIFFORD FA, 1976, NUCL SAFETY, V17, P68