Mussel-inspired enzyme immobilization and dual real-time compensation algorithms for durable and accurate continuous glucose monitoring

被引:39
作者
Kim, Kwang Bok [1 ]
Choi, Hyoungseon [2 ]
Jung, Hyun Joo [2 ]
Oh, Young-Jae [2 ]
Cho, Chul-Ho [2 ]
Min, Jin Hong [2 ]
Yoon, Seoyoung [2 ]
Kim, Jaepil [2 ]
Cho, Seong Je [2 ]
Cha, Hyung Joon [3 ]
机构
[1] Korea Inst Ind Technol, Biomed Syst & Technol Grp, Cheonan 31056, South Korea
[2] Samsung Elect, Samsung Res, Seoul R&D Campus, Seoul 06765, South Korea
[3] Pohang Univ Sci & Technol, Dept Chem Engn, Pohang 37673, South Korea
关键词
Continuous glucose monitoring; Electrochemical sensor; Glucose oxidase immobilization; Mussel adhesive protein; Real-time compensated algorithm; Clinical evaluation; SURFACE MODIFICATION; ELECTRODES; ADSORPTION; BIOSENSOR; ADHESION; OXIDASE;
D O I
10.1016/j.bios.2019.111622
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Blood glucose sensing is very important for diabetic management. It is shifting towards a continuous glucose monitoring because such a system can alleviate patient suffering and provide a large number of glucose measurements. Here, we proposed a novel approach for the development of durable and accurate enzymatic continuous glucose monitoring system (CGMS). For the long-term durable and selective immobilization of glucose oxidase on a microneedle electrode, a biocompatible engineered mussel adhesive protein was employed through efficient electrochemical oxidation strategy. For the accurate performance in in vivo environments, we also suggested dual real-time compensated algorithms to cover both temperature and time-lag differences. After pre-clinical and pilot-clinical evaluations, we confirmed that our proposed CGMS has an outstanding performance compared with various commercially available continuous systems and achieves comparable performance to disposable glucose sensors.
引用
收藏
页数:7
相关论文
共 43 条
[1]  
Atta NF, 2012, INT J ELECTROCHEM SC, V7, P10501
[2]   A MICROELECTROCHEMICAL ENZYME TRANSISTOR RESPONSIVE TO GLUCOSE [J].
BARTLETT, PN ;
BIRKIN, PR .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1552-1559
[3]   ENZYME CATALYSIS AT HYDROGEL-MODIFIED ELECTRODES WITH SOLUBLE REDOX MEDIATOR [J].
BATTAGLINI, F ;
CALVO, EJ .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1994, 90 (07) :987-995
[4]  
Carr P. W, 1980, IMMOBILIZED ENZYME A
[5]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[6]   Surface Modification of Halloysite Nanotubes with Dopamine for Enzyme Immobilization [J].
Chao, Cong ;
Liu, Jindun ;
Wang, Jingtao ;
Zhang, Yanwu ;
Zhang, Bing ;
Zhang, Yatao ;
Xiang, Xu ;
Chen, Rongfeng .
ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (21) :10559-10564
[7]   An interference-free glucose biosensor based on a novel low potential redox polymer mediator [J].
Deng, Huimin ;
Teo, Alan Kay Liang ;
Gao, Zhiqiang .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 :522-528
[8]   Nocturnal hypoglycaemias in type 1 diabetic patients: what can we learn with continuous glucose monitoring? [J].
Guillod, L. ;
Comte-Perret, S. ;
Monbaron, D. ;
Gaillard, R. C. ;
Ruiz, J. .
DIABETES & METABOLISM, 2007, 33 (05) :360-365
[9]  
Hamad K, 2014, POLYM CHEM, V5, P6879
[10]   ENZYME ELECTRODES BASED ON IONOMER FILMS COATED ON ELECTRODES [J].
HARKNESS, JK ;
MURPHY, OJ ;
HITCHENS, GD .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 357 (1-2) :261-272