A simple control strategy for a three-phase shunt active power filter based on second-order sliding mode

被引:0
作者
Mysak, Taras, V [1 ]
Shapoval, Ivan A. [1 ]
机构
[1] Natl Acad Sci Ukraine, Inst Electrodynam, Kiev, Ukraine
来源
2020 IEEE 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT ENERGY AND POWER SYSTEMS (IEPS) | 2020年
关键词
Shunt active power filter; second-order sliding mode; compensating current; sliding surface; movies decomposition;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A simple control strategy of the three-phase shunt active power filter that is connected to a non-linear load network is proposed. The filter consists of a voltage source inverter on fully controlled switches, capacitor storage, and a first-order three-phase RL filter. The decomposition of the object of study according to the rates of motion of the dynamic system was performed. The fast subsystem is a circuit of compensation current control, the slow subsystem performs stabilization of the capacitor voltage. An asymptotic double-twisting algorithm to control the DC voltage was used. For the current formation, a two-dimensional sliding surface is used, which is a linear combination of the components of two-dimensional vectors - the error of the current of the RL filter and some variable. The double-twisting algorithm to calculate the instantaneous value of this variable was also used. A simulation model is developed and the results of digital experiments are analyzed. A comparison of the proposed strategy with the traditional PI-regulation by the criteria of the duration of the transition process and the coefficient of harmonic distortions in the current consumed from the network is made.
引用
收藏
页码:27 / 32
页数:6
相关论文
共 23 条
  • [1] Abraham Babitha T, 2014, INT J ADV RES ELECT
  • [2] [Anonymous], 2017, INT J INN RES EL EL, DOI DOI 10.17148/IJIREEICE/NCAEE.2017.03
  • [3] Sliding mode control of a three-phase parallel active filter based on a two-level voltage converter
    Boum A.T.
    Djidjio Keubeng G.B.
    Bitjoka L.
    [J]. Systems Science and Control Engineering, 2017, 5 (01) : 535 - 543
  • [4] Chen M, 2018, CONTROL OF POWER ELECTRONIC CONVERTERS AND SYSTEMS, VOL 2, P53, DOI 10.1016/B978-0-12-816136-4.00014-2
  • [5] Denisenko K. I., P I EL NAS UKR NOTS, P22, DOI [10.15407/publishing2020.55.022, DOI 10.15407/PUBLISHING2020.55.022]
  • [6] DRAKUNOV SV, 1990, AUTOMAT REM CONTR+, V51, P601
  • [7] Emelyanov S.V., 1990, Mat. Model, V2, P89
  • [8] Gadgune S., 2014, IMPLEMENTATION SHUNT, DOI [10.1109/ICCPCT.2014.7054756, DOI 10.1109/ICCPCT.2014.7054756]
  • [9] Experimental investigations on multitudinal sliding mode controller-based interleaved shunt APF to mitigate shoot-through and PQ problems under distorted supply voltage conditions
    Gali, Vijayakumar
    Gupta, Nitin
    Gupta, R. A.
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (01)
  • [10] Kushal B., 2018, INT J IND ELECT ELEC, V6