Rotating disk electrode study of electrocatalytic oxidation of ascorbate at Prussian blue modified electrode

被引:4
作者
Araminaite, Ruta [1 ]
Garjonyte, Rasa [1 ]
Malinauskas, Albertas [1 ]
机构
[1] Inst Chem, Dept Organ Chem, LT-01108 Vilnius, Lithuania
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2009年 / 7卷 / 04期
关键词
Electrocatalysis; Prussian blue; Ascorbate; Rotating disk electrode; BIOSENSOR; GLUCOSE; OXIDE;
D O I
10.2478/s11532-009-0061-8
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrooxidation of ascorbate has been studied with the use of a rotating disk electrode. The results obtained show an efficient electrocatalytic oxidation of ascorbate at the Prussian blue (PB) modified electrode to proceed in solutions of pH 5.5 and 7.3. Depending on solution pH, the onset potential for ascorbate electrooxidation at PB modified electrode appears shifted by 0.1-0.2 V to lower values, as compared to an unmodified glassy carbon electrode. Within the electrode potential window of 0.3 to 0.5 V vs. Ag/AgCl, and electrode rotation velocity of 50-2000 rpm, the catalytic current obeys Koutecky-Levich equation at a submillimolar ascorbate concentration. Kinetic current densities, obtained from the data treatment, are higher for a pH 5.5 solution, and also at higher electrode potential.
引用
收藏
页码:739 / 744
页数:6
相关论文
共 16 条
[1]  
Bard A.J., 2001, Electrochemical Methods: Fundamentals and Applications, V2, P331
[2]  
Galus Z., 1976, Fundamentals of Electrochemical Analysis
[3]   Amperometric detection of morphine at a Prussian blue-modified indium tin oxide electrode [J].
Ho, KC ;
Chen, CY ;
Hsu, HC ;
Chen, LC ;
Shiesh, SC ;
Lin, XZ .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (01) :3-8
[4]   LIQUID-CHROMATOGRAPHY WITH ELECTROCATALYTIC DETECTION OF CYSTEINE, N-ACETYLCYSTEINE AND GLUTATHIONE BY A PRUSSIAN BLUE FILM-MODIFIED ELECTRODE [J].
HOU, WY ;
WANG, EK .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 316 (1-2) :155-163
[5]  
Karyakin AA, 2001, ELECTROANAL, V13, P813, DOI 10.1002/1521-4109(200106)13:10<813::AID-ELAN813>3.0.CO
[6]  
2-Z
[7]   A HIGH-SENSITIVE GLUCOSE AMPEROMETRIC BIOSENSOR BASED ON PRUSSIAN-BLUE MODIFIED ELECTRODES [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL LETTERS, 1994, 27 (15) :2861-2869
[8]   PRUSSIAN BLUE BASED FIRST-GENERATION BIOSENSOR - A SENSITIVE AMPEROMETRIC ELECTRODE FOR GLUCOSE [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2419-2423
[9]  
Malinauskas A, 2006, CHEM ANAL-WARSAW, V51, P809
[10]   Modeling of electrocatalytic processes at conducting polymer modified electrodes [J].
Naujikas, R. ;
Malinauskas, A. ;
Ivanauskas, F. .
JOURNAL OF MATHEMATICAL CHEMISTRY, 2007, 42 (04) :1069-1084