One-Minute Fish Freshness Evaluation by Testing the Volatile Amine Gas with an Ultrasensitive Porous-Electrode-Capped Organic Gas Sensor System

被引:169
作者
Chang, Liang-Yu [1 ,2 ]
Chuang, Ming-Yen [1 ,2 ]
Zan, Hsiao-Wen [1 ,2 ]
Meng, Hsin-Fei [3 ]
Lu, Chia-Jung [4 ]
Yeh, Ping-Hung [5 ]
Chen, Jian-Nan [6 ]
机构
[1] Natl Chiao Tung Univ, Dept Photon, 1001 Ta Hsueh Rd, Hsinchu 300, Taiwan
[2] Natl Chiao Tung Univ, Inst Electroopt Engn, Hsinchu 300, Taiwan
[3] Natl Chiao Tung Univ, Inst Phys, Hsinchu 300, Taiwan
[4] Natl Taiwan Normal Univ, Dept Chem, Taipei 106, Taiwan
[5] Tamkang Univ, Dept Phys, New Taipei 25137, Taiwan
[6] Natl Tsing Hua Univ, Inst Elect Engn, Hsinchu 300, Taiwan
关键词
gas sensor; amine gas; fish freshness; volatile basic nitrogen; ammonia; dimethylamine; trimethylamine; P3HT; QUALITY; OXIDE;
D O I
10.1021/acssensors.6b00829
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, we successfully demonstrate a fast method to determine the fish freshness by using a sensing system containing an ultrasensitive amine gas sensor to detect the volatile amine gas from the raw fish meat. When traditional titration method takes 4 h and complicated steps to test the total volatile basic nitrogen (TVB-N) as a worldwide standard for fish freshness, our sensor takes 1 min to deliver an electrical sensing response that is highly correlated with the TVB-N value. When detecting a fresh fish with a TVB-N as 18 mg/100 g, the sensor delivers an effective ammonia concentration as 100 ppb. For TVB-N as 28-35 mg/100 g, a well-accepted freshness limit, the effective ammonia concentration is as 200-300 ppb. The ppb-regime sensitivity of the sensor and the humidity control in the sensing system are the keys to realizing fast and accurate detection. It is expected that the results in this report enable the development of on-site freshness detection and real-time monitoring in a fish factory.
引用
收藏
页码:531 / 539
页数:9
相关论文
共 22 条
[1]   A novel liquid chromatography-mass spectrometric method for the simultaneous determination of trimethylamine, dimethylamine and methylamine in fishery products [J].
Balino-Zuazo, Lander ;
Barranco, Alejandro .
FOOD CHEMISTRY, 2016, 196 :1207-1214
[2]   Recent Advances in Methods and Techniques for Freshness Quality Determination and Evaluation of Fish and Fish Fillets: A Review [J].
Cheng, Jun-Hu ;
Sun, Da-Wen ;
Zeng, Xin-An ;
Liu, Dan .
CRITICAL REVIEWS IN FOOD SCIENCE AND NUTRITION, 2015, 55 (07) :1012-1025
[3]   Applications of non-destructive spectroscopic techniques for fish quality and safety evaluation and inspection [J].
Cheng, Jun-Hu ;
Dai, Qiong ;
Sun, Da-Wen ;
Zeng, Xin-An ;
Liu, Dan ;
Pu, Hong-Bin .
TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2013, 34 (01) :18-31
[4]   Gas permeable silver nanowire electrode for realizing vertical type sensitive gas sensor [J].
Chuang, Ming-Yen ;
Zan, Hsiao-Wen ;
Yu, Peichen ;
Lai, Yi-Chun ;
Meng, Hsin-Fei .
ORGANIC ELECTRONICS, 2014, 15 (11) :2769-2774
[5]  
CHUANG MY, SENS ACTUATORS B, V230, P223
[6]   Highly Sensitive Ammonia Sensor with Organic Vertical Nanojunctions for Noninvasive Detection of Hepatic Injury [J].
Dai, Ming-Zhi ;
Lin, Yi-Lo ;
Lin, Hung-Cheng ;
Zan, Hsiao-Wen ;
Chang, Kai-Ting ;
Meng, Hsin-Fei ;
Liao, Jiunn-Wang ;
Tsai, May-Jywan ;
Cheng, Henrich .
ANALYTICAL CHEMISTRY, 2013, 85 (06) :3110-3117
[7]   Comparison and integration of different electronic noses for freshness evaluation of cod-fish fillets [J].
Di Natale, C ;
Olafsdottir, G ;
Einarsson, S ;
Martinelli, E ;
Paolesse, R ;
D'Amico, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) :572-578
[8]   A semiconducting metal-oxide array for monitoring fish freshness [J].
Hammond, J ;
Marquis, B ;
Michaels, R ;
Oickle, B ;
Segee, B ;
Vetelino, J ;
Bushway, A ;
Camire, ME ;
Davis-Dentici, K .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 84 (2-3) :113-122
[9]  
HAN S, SENS ACTUATORS B, V225, P10
[10]   A non-destructive ammonium detection method as indicator for freshness for packed fish: Application on cod [J].
Heising, J. K. ;
Dekker, M. ;
Bartels, P. V. ;
van Boekel, M. A. J. S. .
JOURNAL OF FOOD ENGINEERING, 2012, 110 (02) :254-261