IDeF-X ECLAIRs: A CMOS ASIC for the Readout of CdTe and CdZnTe Detectors for High Resolution Spectroscopy

被引:46
作者
Gevin, Olivier [1 ]
Baron, Pascal [1 ]
Coppolani, Xavier [1 ]
Daly, Francois [2 ]
Delagnes, Eric [1 ]
Limousin, Olivier [2 ]
Lugiez, Francis [1 ]
Meuris, Aline [2 ]
Pinsard, Frederic [2 ]
Renaud, Diana [2 ]
机构
[1] CEA Saclay, DSM, IRFU, Serv Elect Detecteurs & Informat, F-91191 Gif Sur Yvette, France
[2] CEA Saclay, DSM, IRFU, Serv Astrophys, F-91191 Gif Sur Yvette, France
关键词
ASIC; CdTe; CdZnTe; CMOS; hard X-ray spectroscopy; latch up; noise; Simbol-X; SVOM; RAY; MULTIWAVELENGTH;
D O I
10.1109/TNS.2009.2023989
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The very last member of the IDeF-X ASIC family is presented: IDeF-X ECLAIRs is a 32-channel front end ASIC designed for the readout of Cadmium Telluride (CdTe) and Cadmium Zinc Telluride (CdZnTe) Detectors. Thanks to its noise performance (Equivalent Noise Charge floor of 33 e(-) rms) and to its radiation hardened design (Single Event Latchup Linear Energy Transfer threshold of 56 MeV.cm(2).mg(-1)), the chip is well suited for soft X-rays energy discrimination and high energy resolution, "space proof," hard X-ray spectroscopy. We measured an energy low threshold of less than 4 keV with a 10 pF input capacitor and a minimal reachable sensitivity of the Equivalent Noise Charge (ENC) to input capacitance of less than 7e(-)/pF obtained with a 6 mu s peak time. IDeF-X ECLAIRs will be used for the readout of 6400 CdTe Schottky monopixel detectors of the 2D coded mask imaging telescope ECLAIRs aboard the SVOM satellite [1]. IDeF-X ECLAIRs (or IDeF-X V2) has also been designed for the readout of a pixelated CdTe detector in the miniature spectro-imager prototype Caliste 256 [2] that is currently foreseen for the high energy detector module of the Simbol-X mission [3].
引用
收藏
页码:2351 / 2359
页数:9
相关论文
共 30 条
  • [1] [Anonymous], 2008, PROC IEEE NSS MIC C
  • [2] Bendat J., 1958, PRINCIPLES APPLICATI, V127
  • [3] Chang Z.Y., 1991, LOW NOISE WIDE BAND, P160
  • [4] ECLAIRs: A microsatellite for the Multi-Wavelength Study of Gamma-Ray Burst Prompt Emission
    Cordier, B
    Paul, J
    Barret, D
    Skinner, G
    Atteia, JL
    Ricker, G
    [J]. X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 1188 - 1195
  • [5] Hand-Held Gamma-Ray Spectrometer Based on High-Efficiency Frisch-Ring CdZnTe Detectors
    Cui, Yonggang
    Bolotnikov, Aleksey
    Camarda, Giuseppe
    Hossain, Anwar
    James, Ralph B.
    De Geronimo, Gianluigi
    Fried, Jack
    O'Connor, Paul
    Kargar, Alireza
    Harrison, Mark J.
    McGregor, Douglas S.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2765 - 2769
  • [6] DEGERONIMO G, 1999, P IEEE NSS MIC
  • [7] Leakage current measurements on pixelated CdZnTe detectors
    Dirks, B. P. F.
    Blondel, C.
    Daly, F.
    Gevin, O.
    Limousin, O.
    Lugiez, F.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01) : 145 - 149
  • [8] DIRKS BPF, 2006, P SPIE C, V6276
  • [9] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 1191 - 1198
  • [10] FERRANDO P, 2006, P SPIE C, V6266