Advances in chromatographic techniques and methods in shotgun proteome analysis

被引:46
作者
Ye, Mingliang [1 ]
Jiang, Xiaogang [1 ]
Feng, Shun [1 ]
Tian, Ruijun [1 ]
Zou, Hanfa [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&D Ctr, Dalian 116023, Peoples R China
基金
中国国家自然科学基金;
关键词
automated proteome-analysis system; multidimensional separation; one-dimensional separation; separation technique; shotgun proteomics;
D O I
10.1016/j.trac.2006.10.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Shotgun proteomics is a high-throughput approach to proteome analysis whereby the protein mixture is digested and the peptides generated are separated by capillary liquid chromatography and sequenced by tandem mass spectrometry (MS). Due to the huge number of peptide species, separation prior to MS analysis plays an important role in shotgun proteomics. Overall sensitivity, dynamic range, throughput and general effectiveness of shotgun proteomic analysis largely depend on how well the peptide mixture is separated. In recent years, new separation techniques have been applied successfully to proteome analysis and have dramatically improved protein identification. We briefly review the recent development of chromatographic techniques and methods in shotgun proteome analysis, including the following three aspects: one-dimensional separation; multidimensional separation; and, automated proteome-analysis systems. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 57 条
[31]   Fully automated micro- and nanoscale one- or two-dimensional high-performance liquid chromatography system for liquid chromatography-mass spectrometry compatible with non-volatile salts for ion exchange chromatography [J].
Masuda, J ;
Maynard, DA ;
Nishimura, M ;
Uedac, T ;
Kowalak, JA ;
Markey, SP .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1063 (1-2) :57-69
[32]   Effect of skeleton size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :135-146
[33]   Automated, on-line two-dimensional nano liquid chromatography tandem mass spectrometry for rapid analysis of complex protein digests [J].
Mitulovic, G ;
Stingl, C ;
Smoluch, M ;
Swart, R ;
Chervet, JP ;
Steinmacher, I ;
Gerner, C ;
Mechtler, K .
PROTEOMICS, 2004, 4 (09) :2545-2557
[34]   Two-dimensional nano-liquid chromatography-mass spectrometry system for applications in proteomics [J].
Nägele, E ;
Vollmer, M ;
Hörth, P .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1009 (1-2) :197-205
[35]  
Nakanishi K, 2000, HRC-J HIGH RES CHROM, V23, P106
[36]   Two-dimensional SEC/RPLC coupled to mass spectrometry for the analysis of peptides [J].
Opiteck, GJ ;
Jorgenson, JW ;
Anderegg, RJ .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2283-2291
[37]   Proteomics: the move to mixtures [J].
Peng, JM ;
Gygi, SP .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (10) :1083-1091
[38]   Evaluation of multidimensional chromatography coupled with tandem mass spectrometry (LC/LC-MS/MS) for large-scale protein analysis: The yeast proteome [J].
Peng, JM ;
Elias, JE ;
Thoreen, CC ;
Licklider, LJ ;
Gygi, SP .
JOURNAL OF PROTEOME RESEARCH, 2003, 2 (01) :43-50
[39]   Ultrasensitive proteomics using high-efficiency on-line micro-SPE-NanoLC-NanoESI MS and MS/MS [J].
Shen, Y ;
Tolic, N ;
Masselon, C ;
Pasa-Tolic, L ;
Camp, DG ;
Hixson, KK ;
Zhao, R ;
Anderson, GA ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2004, 76 (01) :144-154
[40]   High-efficiency on-line solid-phase extraction coupling to 15-150-μm-id column liquid chromatography for proteomic analysis [J].
Shen, YF ;
Moore, RJ ;
Zhao, R ;
Blonder, J ;
Auberry, DL ;
Masselon, C ;
Pasa-Tolic, L ;
Hixson, KK ;
Auberry, KJ ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3596-3605