Megavoltage CT imaging as a by-product of multileaf collimator leakage

被引:21
|
作者
Ruchala, KJ
Olivera, GH
Kapatoes, JM
Schloesser, EA
Reckwerdt, PJ
Mackie, TR
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Tomotherapy Inc, Middleton, WI 53562 USA
[3] Univ Wisconsin, Dept Human Oncol, Madison, WI 53706 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2000年 / 45卷 / 07期
关键词
D O I
10.1088/0031-9155/45/7/401
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In addition to their potential for the delivery of highly conformal radiation therapy treatments, tomotherapeutic treatments also Feature increased potential for verification. For example, megavoltage CT allows one to use the megavoltage linac to generate tomographic images of the patient in the treatment position. This is typically done before or after radiation therapy treatments. However, it is also possible to collect MVCT images entirely during the treatment itself. This process utilizes the leakage radiation through the closed leaves of the Nomos MIMiC MLC, along with slight inefficiencies in treatment delivery, to generate MVCT images during treatment that require neither additional time nor dose. The image quality is limited, yet sufficient to see a patient's external boundary, density differences over 8% for 25.0 mm objects and resolutions of 3.0 mm for high-contrast objects. Such images can potentially be viewed during treatment, used to flag additional CT immediately after the treatment and provide a representation of the patient's exact position during treatment for use with dose reconstruction.
引用
收藏
页码:N61 / N70
页数:10
相关论文
共 50 条
  • [21] Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration
    Baker, SJK
    Budgell, GJ
    MacKay, RI
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (07): : 1377 - 1392
  • [22] Extended range CT-value analysis in megavoltage CT imaging and therapy
    Ozer, M.
    Hui, S.
    Gerbi, B.
    Higgins, P.
    Alaei, Parham
    Dusenbery, K.
    MEDICAL PHYSICS, 2006, 33 (06) : 2219 - 2219
  • [23] Multileaf collimator tracking integrated with a novel x-ray imaging system and external surrogate monitoring
    Krauss, Andreas
    Fast, Martin F.
    Nill, Simeon
    Oelfke, Uwe
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (08): : 2425 - 2439
  • [24] Use of megavoltage CT imaging for quantifying treatment setup uncertainties
    Stathakis, S.
    Shi, C.
    Mavroidis, P.
    Giantsoudi, D.
    Swanson, G.
    Esquivel, C.
    Ferreira, B. C.
    Komisopoulos, G.
    Papanikolaou, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S660 - S660
  • [25] Is there an increased role for megavoltage CT imaging in radiation therapy (and beyond)?
    Brundage, M
    Rogers, M
    Kerr, A
    Salomons, G
    Mackillop, W
    Schreiner, LJ
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S32 - S32
  • [26] Design of a Primary Collimator for Cone Beam CT Imaging
    Grant, J.
    Dhanesar, S.
    Joshi, C.
    Darko, J.
    Schreiner, L. J.
    Kerr, A.
    MEDICAL PHYSICS, 2009, 36 (09) : 4310 - 4310
  • [27] Megavoltage CT from Electronic Portal Imaging of VMAT Deliveries
    Wood, J. S.
    Marchant, T. E.
    Budgell, G. J.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S18 - S18
  • [28] Evaluation of megavoltage CT imaging protocols in patients with lung cancer
    Smith, S.
    Yartsev, S.
    Van Dyk, J.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (01) : 62 - 68
  • [29] Imaging performance of a bench-top megavoltage CT scanner
    Monajemi, T
    Tu, D
    Fallone, B
    Rathee, S
    MEDICAL PHYSICS, 2005, 32 (07) : 2426 - 2426
  • [30] Clinical megavoltage CT - Imaging scenarios from routine to extreme
    Ruchala, K
    Olivera, G
    Kapatoes, J
    Balog, J
    Welsh, J
    Lu, W
    Jeraj, R
    Mackie, T
    MEDICAL PHYSICS, 2003, 30 (06) : 1476 - 1476