Estimating myocardial motion by 4D image warping

被引:35
|
作者
Sundar, Hari [1 ]
Litt, Harold [2 ]
Shen, Dinggang [1 ,3 ,4 ]
机构
[1] Univ Penn, Sch Med, Dept Radiol, Sect Biomed Image Anal, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Dept Radiol, Cardiovasc Imaging Sect, Philadelphia, PA 19104 USA
[3] Univ N Carolina, Dept Radiol, Chapel Hill, NC USA
[4] Univ N Carolina, BRIC, Chapel Hill, NC USA
关键词
Image registration; Cardiac motion estimation; Spatio-temporal normalization; TAGGED MR-IMAGES; REGISTRATION; DEFORMATION;
D O I
10.1016/j.patcog.2009.04.022
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A method for spatio-temporally smooth and consistent estimation of cardiac motion from MR cine sequences is proposed. Myocardial motion is estimated within a four-dimensional (4D) registration framework, in which all three-dimensional (3D) images obtained at different cardiac phases are simultaneously registered. This facilitates spatio-temporally consistent estimation of motion as opposed to other registration-based algorithms which estimate the motion by sequentially registering one frame to another. To facilitate image matching, an attribute vector (AV) is constructed for each point in the image, and is intended to serve as a "morphological signature" of that point. The AV includes intensity, boundary, and geometric moment invariants (GMIs). Hierarchical registration of two image sequences is achieved by using the most distinctive points for initial registration of two sequences and gradually adding less-distinctive points to refine the registration. Experimental results on real data demonstrate good performance of the proposed method for cardiac image registration and motion estimation. The motion estimation is validated via comparisons with motion estimates obtained from MR images with myocardial tagging. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2514 / 2526
页数:13
相关论文
共 50 条
  • [41] Optimal Landmark Selection for Registration of 4D Confocal Image Stacks in Arabidopsis
    Mkrtchyan, Katya
    Chakraborty, Anirban
    Roy-Chowdhury, Amit K.
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2017, 14 (02) : 457 - 467
  • [42] A generalized 4D image registration scheme for targeted radionuclide therapy dosimetry
    Papavasileiou, Periklis
    Divoli, Antigoni
    Hatziioannou, Kostas
    Flux, Glenn D.
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2007, 22 (01) : 160 - 165
  • [43] Dependence of ventilation image derived from 4D CT on deformable image registration and ventilation algorithms
    Latifi, Kujtim
    Forster, Kenneth M.
    Hoffe, Sarah E.
    Dilling, Thomas J.
    van Elmpt, Wouter
    Dekker, Andre
    Zhang, Geoffrey G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 150 - 162
  • [44] Motion Vector Field Upsampling for Improved 4D Cone-Beam CT Motion Compensation of the Thorax
    Sauppe, Sebastian
    Rank, Christopher M.
    Brehm, Marcus
    Paysan, Pascal
    Seghers, Dieter
    Kachelriess, Marc
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [45] Directional Interpolation for Motion Weighted 4D Cone-Beam CT Reconstruction
    Zhang, Hua
    Sonke, Jan-Jakob
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 181 - 188
  • [46] Lung motion estimation by robust point matching and spatiotemporal tracking for 4D CT
    Yi, Jianbing
    Yang, Hao
    Yang, Xuan
    Chen, Guoliang
    COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 78 : 107 - 119
  • [47] 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling
    Zhong, Zichun
    Gu, Xuejun
    Mao, Weihua
    Wang, Jing
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03) : 996 - 1020
  • [48] LOCAL MOTION ANALYSIS IN 4D LUNG CT USING FAST GROUPWISE REGISTRATION
    Bystrov, D.
    Vik, T.
    Schulz, H.
    Klinder, T.
    Schmidt, S.
    2009 16TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-6, 2009, : 1749 - +
  • [49] Shape-correlated Deformation Statistics for Respiratory Motion Prediction in 4D Lung
    Liu, Xiaoxiao
    Oguz, Ipek
    Pizer, Stephen M.
    Mageras, Gig S.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [50] Non-rigid dual respiratory and cardiac motion correction methods after, during, and before image reconstruction for 4D cardiac PET
    Feng, Tao
    Wang, Jizhe
    Fung, George
    Tsui, Benjamin
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01) : 151 - 168