We have estimated count rate properties of 3D PET scanners based on a GSO detector with depth of interaction (DOI) capability using a large area position-sensitive photomultiplier tube (PS-PMT). The proposed detector unit consists of 64 crystal blocks with four stages of 2 x 2 GSO arrays coupled to a 52 mm square PS-PMT which has small dead space. With appropriate light control in the crystal block, DOI information can be obtained using simple Anger-type positioning logic. Thus dead time factors can be calculated using a count rate model with standard acquisition architecture. Compton and photoelectric interactions in the scintillator and uniform cylindrical phantoms were tracked by Monte Carlo simulation programs. Since the DOI detector can provide high resolution throughout entire field of view, 3D PET scanners with a large solid angle covered by the detectors with relatively small ring diameters were simulated. The preliminary results suggest that, compared to current PET scanners, high noise equivalent count rate can be obtained by the proposed scanner designs despite the relatively large size of the detector module. The count rate performance can be improved by the reduction of single events that cause block dead time losses at the cost of a slight decrease in sensitivity.
引用
收藏
页码:1208 / 1212
页数:5
相关论文
共 5 条
  • [1] Count rate analysis of PET scanner designs based on a GSO depth of interaction detector with a large-area PS-PMT
    Kitamura, K
    Amano, MR
    Murayama, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2218 - 2222
  • [2] Design of a depth of interaction detector with a PS-PMT for PET
    Murayama, H
    Ishibashi, H
    Uchida, H
    Omura, T
    Yamashita, T
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1062 - 1066
  • [3] Design of a depth of interaction detector with a PS-PMT for PET
    Murayama, H.
    Ishibashi, H.
    Uchida, H.
    Omura, T.
    Yamashita, T.
    IEEE Transactions on Nuclear Science, 2000, 47 (3 III) : 1045 - 1050
  • [4] Design of a depth of interaction detector with a PS-PMT for PET
    Murayama, H
    Ishibashi, H
    Uchida, H
    Omura, T
    Yamashita, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1045 - 1050
  • [5] A depth-of-interaction encoding PET detector module with dual-ended readout using large-area silicon photomultiplier arrays
    Du, Junwei
    Bai, Xiaowei
    Cherry, Simon R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (24):