Quantitative Pulmonary Perfusion Magnetic Resonance Imaging Influence of Temporal Resolution and Signal-to-Noise Ratio

被引:28
作者
Ingrisch, Michael [1 ]
Dietrich, Olaf [1 ]
Attenberger, Ulrike I. [2 ]
Nikolaou, Konstantin
Sourbron, Steven [1 ]
Reiser, Maximilian F.
Fink, Christian [2 ]
机构
[1] Univ Munich, Josef Lissner Lab Biomed Imaging, Inst Clin Radiol, Munich Univ Hosp Grosshadern, D-81377 Munich, Germany
[2] Univ Heidelberg, Dept Clin Radiol & Nucl Med, Univ Med Ctr Mannheim, D-6800 Mannheim, Germany
关键词
lung; dynamic contrast-enhanced MRI; perfusion; pulmonary blood flow and volume; CONTRAST-ENHANCED MRI; BLOOD-FLOW; QUANTIFICATION; DECONVOLUTION; ANGIOGRAPHY; ACQUISITION;
D O I
10.1097/RLI.0b013e3181bc2d0c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the influence of the contrast-to-noise ratio (CNR) and temporal resolution of 3D dynamic contrast-enhanced magnetic resonance imaging on the quantification of pulmonary perfusion parameters by means of Monte-Carlo simulations and a volunteer study. Methods: Quantification of perfusion parameters such as pulmonary blood flow (PBF) and pulmonary blood volume.(PBV) was simulated using synthetic data with varying CNR (noise standard deviations ranging from 0% to 25% of the parenchymal signal maximum) and different temporal resolutions from I to 5 seconds. Simulation results were compared with perfusion measurements in 9 healthy volunteers (age: 18-31) using dynamic 3D gradient-echo sequences with different k-space acquisition schemes, resulting in different temporal resolutions of 1.1, 1.3, and 2.0 seconds per volume and varying CNR. Lung parenchyma was segmented using a semiautomatic technique, and PBF, PBV, as well as MTT were determined pixelwise using Tikhonov-regularized deconvolution with an optimized L-curve criterion. Results: The simulations showed a breakdown of the deconvolution algorithm for temporal resolutions lower than 3 s. PBF was increasingly underestimated with decreasing CNR; the temporal resolution had little influence on PBF estimates in the investigated range. PBV, on the other hand, was more dependent on the temporal resolution and showed less, but noticeable influence of the CNR. For low temporal resolutions, PBV was overestimated. In the volunteer study, no significant differences of PBF between the different sequences were found; however, PBV was underestimated by the slowest sequence, in contrast to the simulation results. Conclusion: Both the mathematical simulations and volunteer measurements showed that the temporal resolution has less influence than the CNR on the quantification of PBF. On the other hand, PBV is more influenced by temporal resolution than by CNR. This indicates that the gain in measurement speed that can be obtained by modem acceleration schemes need not be invested in ultra-high temporal resolution. Instead, sequence optimization should aim for a suitable balance of sufficient CNR on the one hand, and sufficient temporal resolution on the other hand, whereas maintaining a high spatial resolution.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 21 条
[1]   Fast oxygen-enhanced multislice imaging of the lung using parallel acquisition techniques [J].
Dietrich, O ;
Losert, C ;
Attenberger, U ;
Fasol, U ;
Peller, M ;
Nikolaou, K ;
Reiser, MF ;
Schoenberg, SO .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) :1317-1325
[2]   Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385
[3]   Effect of inspiratory and expiratory breathhold on pulmonary perfusion - Assessment by pulmonary perfusion magnetic resonance Imaging [J].
Fink, C ;
Ley, S ;
Risse, F ;
Eichinger, M ;
Zaporozhan, J ;
Buhmann, R ;
Puderbach, M ;
Plathow, C ;
Kauczor, HU .
INVESTIGATIVE RADIOLOGY, 2005, 40 (02) :72-79
[4]  
Fink C, 2005, INVEST RADIOL, V40, P40
[5]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[6]   Resolution enhancement in lung 1H imaging using parallel imaging methods [J].
Heidemann, RM ;
Griswold, MA ;
Kiefer, B ;
Nittka, M ;
Wang, J ;
Jellus, V ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) :391-394
[7]   Quantitatively assessed dynamic contrast-enhanced magnetic resonance imaging in patients with chronic obstructive pulmonary disease: Correlation of perfusion parameters with pulmonary function test and quantitative computed tomography [J].
Jang, Yu Mi ;
Oh, Yeon-Mok ;
Seo, Joon Beom ;
Kim, Namkug ;
Chae, Eun Jin ;
Lee, Young Kyung ;
Lee, Sang Do .
INVESTIGATIVE RADIOLOGY, 2008, 43 (06) :403-410
[8]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[9]   Impact of oxygen inhalation on the pulmonary circulation - Assessment by magnetic resonance (MR)-perfusion and MR-flow measurements [J].
Ley, Sebastian ;
Puderbach, Michael ;
Risse, Frank ;
Ley-Zaporozhan, Julia ;
Eichingrer, Monika ;
Takenaka, Daisuke ;
Kauczor, Hans-Ulrich ;
Bock, Michael .
INVESTIGATIVE RADIOLOGY, 2007, 42 (05) :283-290
[10]   Quantitative 3D pulmonary MR-perfusion in patients with pulmonary arterial hypertension:: Correlation with invasive pressure measurements [J].
Ley, Sebastian ;
Mereles, Derliz ;
Risse, Frank ;
Gruenig, Ekkehard ;
Ley-Zaporozhan, Julia ;
Tecer, Zueleyha ;
Puderbach, Michael ;
Fink, Christian ;
Kauczor, Hans-Ulrich .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 61 (02) :251-255