Sampling of benzene in environmental and exhaled air by solid-phase microextraction and analysis by gas chromatography-mass spectrometry

被引:24
作者
Menezes, Helvecio C. [1 ]
Amorim, Leiliane C. A. [1 ]
Cardeal, Zenilda L. [1 ]
机构
[1] Univ Fed Minas Gerais, ICEx, Dept Chem, BR-31270901 Belo Horizonte, MG, Brazil
关键词
Benzene; Environmental analysis; Breath analysis; SPME; GC/MS; VOLATILE ORGANIC-COMPOUNDS; INDOOR AIR; EXPOSURE; BREATH;
D O I
10.1007/s00216-009-3206-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Benzene is classified as a Group I carcinogen by the International Agency for Research on Cancer (IARC). The risk assessment for benzene can be performed by monitoring environmental and occupational air, as well as biological monitoring through biomarkers. The present work developed and validated methods for benzene analysis by GC/MS using SPME as the sampling technique for ambient air and breath. The results of the analysis of air in parks and avenues demonstrated a significant difference, with average values of 4.05 and 18.26 mu g m(-3), respectively, for benzene. Sampling of air in the occupational environment furnished an average of 3.41 and 39.81 mu g m(-3). Moreover, the correlations between ambient air and expired air showed a significant tendency to linearity (R (2) = 0.850 and R (2) = 0.879). The results obtained for two groups of employees (31.91 and 72.62 mu g m(-3)) presented the same trend as that from the analysis of environmental air.
引用
收藏
页码:2583 / 2589
页数:7
相关论文
共 30 条
  • [1] ABALAK R, 2001, ENVIRON SCI TECHNOL, V35, P2650
  • [2] American Conference of Governmental Industrial Hygienists (ACGIH), 2008, THRESH LIM VAL CHEM
  • [3] An optimized method for determination of benzene in exhaled air by gas chromatography-mass spectrometry using solid phase microextraction as a sampling technique
    Amorim, Leiliane C. A.
    Carneiro, Joana P.
    Cardeal, Zenilda L.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 865 (1-2): : 141 - 146
  • [4] [Anonymous], 2006, DEV WHO GUID IND AIR
  • [5] Reliability of a BTEX radial diffusive sampler for thermal desorption: field measurements
    Bruno, P
    Caputi, M
    Caselli, M
    de Gennaro, G
    de Rienzo, M
    [J]. ATMOSPHERIC ENVIRONMENT, 2005, 39 (07) : 1347 - 1355
  • [6] Risk of benzene-induced leukemia predicted from the Pliofilm cohort
    Crump, KS
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1996, 104 : 1437 - 1441
  • [7] Sample preparation for the analysis of volatile organic compounds in air and water matrices
    Demeestere, Kristof
    Dewulf, Jo
    De Witte, Bavo
    Van Langenhove, Herman
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1153 (1-2) : 130 - 144
  • [8] Self-collected breath sampling for monitoring low-level benzene exposures among automobile mechanics
    Egeghy, PP
    Nylander-French, L
    Gwin, KK
    Hertz-Picciotto, I
    Rappaport, SM
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 2002, 46 (05) : 489 - 500
  • [9] EGEHY PP, 2003, OCCUP ENVIRON MED, V60, P969
  • [10] EGEHY PP, 2002, ENV HLTH PERSP, V108, P1195