Computational Modeling of Radiofrequency Ablation: Evaluation on Ex Vivo Data Using Ultrasound Monitoring

被引:0
作者
Audigier, Chloe [1 ,2 ]
Kim, Younsu [1 ]
Dillow, Austin [3 ]
Boctor, Emad M. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD 21218 USA
来源
MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2017年 / 10135卷
基金
美国国家卫生研究院;
关键词
Radiofrequency ablation; Computational modeling; Ultrasound thermal monitoring; Ex vivo Validation; TISSUE;
D O I
10.1117/12.2254986
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Radiofrequency ablation (RFA) is the most widely used minimally invasive ablative therapy for liver cancer, but it is challenged by a lack of patient-specific monitoring. Inter-patient tissue variability and the presence of blood vessels make the prediction of the RFA difficult. A monitoring tool which can be personalized for a given patient during the intervention would be helpful to achieve a complete tumor ablation. However, the clinicians do not have access to such a tool, which results in incomplete treatment and a large number of recurrences. Computational models can simulate the phenomena and mechanisms governing this therapy. The temperature evolution as well as the resulted ablation can be modeled. When combined together with intra-operative measurements, computational modeling becomes an accurate and powerful tool to gain quantitative understanding and to enable improvements in the ongoing clinical settings. This paper shows how computational models of RFA can be evaluated using intra-operative measurements. First, simulations are used to demonstrate the feasibility of the method, which is then evaluated on two ex vivo datasets. RFA is simulated on a simplified geometry to generate realistic longitudinal temperature maps and the resulted necrosis. Computed temperatures are compared with the temperature evolution recorded using thermometers, and with temperatures monitored by ultrasound (US) in a 2D plane containing the ablation tip. Two ablations are performed on two cadaveric bovine livers, and we achieve error of 2.2 degrees C on average between the computed and the thermistors temperature and 1.4 degrees C and 2.7 degrees C on average between the temperature computed and monitored by US during the ablation at two different time points (t = 240 s and t = 900 s).
引用
收藏
页数:10
相关论文
共 8 条
[1]  
Audigier C, 2015, COMPUTATIONAL BIOMEC, P29
[2]   Efficient Lattice Boltzmann Solver for Patient-Specific Radiofrequency Ablation of Hepatic Tumors [J].
Audigier, Chloe ;
Mansi, Tommaso ;
Delingette, Herve ;
Rapaka, Saikiran ;
Mihalef, Viorel ;
Carnegie, Daniel ;
Boctor, Emad ;
Choti, Michael ;
Kamen, Ali ;
Ayache, Nicholas ;
Comaniciu, Dorin .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (07) :1576-1589
[3]   CURRENT CONCEPTS Hepatocellular Carcinoma [J].
El-Serag, Hashem B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (12) :1118-1127
[4]  
Kim Y., 2016, P SOC PHOTO-OPT INS, V9790
[5]   Image-based multi-scale modelling and validation of radio-frequency ablation in liver tumours [J].
Payne, Stephen ;
Flanagan, Ronan ;
Pollari, Mika ;
Alhonnoro, Tuomas ;
Bost, Claire ;
O'Neill, David ;
Peng, Tingying ;
Stiegler, Philipp .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2011, 369 (1954) :4233-4254
[6]   Analysis of tissue and arterial blood temperatures in the resting human forearm (Reprinted from Journal of Applied Physiology, vol 1, pg 93-122, 1948) [J].
Pennes, HH .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (01) :5-34
[7]   THERMAL DOSE DETERMINATION IN CANCER-THERAPY [J].
SAPARETO, SA ;
DEWEY, WC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (06) :787-800
[8]   A multi-gate time-of-flight technique for estimation of temperature distribution in heated tissue: theory and computer simulation [J].
Sun, ZG ;
Ying, H .
ULTRASONICS, 1999, 37 (02) :107-122