MR anatomy and small lesions of the eye: Improved delineation with a special surface coil

被引:20
作者
Hosten, N
Lemke, AJ
Sander, B
Wassmuth, R
Terstegge, K
Bornfeld, N
Felix, R
机构
[1] FREE UNIV BERLIN,KLINIKUM BENJAMIN FRANKLIN,AUGENKLIN & POLIKLIN,D-12200 BERLIN,GERMANY
[2] UNIV SAARLAND,FAK MED,INST NEURORADIOL,D-66424 HOMBURG,GERMANY
关键词
MR; surface coils; pulse sequences; eye; neoplasms;
D O I
10.1007/s003300050183
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To develop an improved investigation protocol for MRI studies of intraocular lesions, imaging with a small surface coil (diameter 6 cm) was compared with a standard surface coil (diameter 11 cm). Both coils were assessed initially on an eye phantom and then by studying 22 patients with uveal melanoma and similar lesions of the eye. The influence of bandwidth and field or view (FOV) were systematically studied and evaluated quantitatively. A smaller bandwidth improved image quality independent of surface coil size. The subsequent secondary increase in chemical shift artefact was acceptable. Smaller FOVs (60-80 mm) necessitated the use of a smaller surface coil. A smaller bandwidth also proved to be advantageous with the use of the smaller surface coil. In conclusion, a smaller-diameter surface coil improves MR imaging of ocular lesions. Pulse sequences with a small bandwidth maintain an acceptable signal-to-noise ratio when the FOV is reduced.
引用
收藏
页码:459 / 463
页数:5
相关论文
共 9 条
[1]  
DEPOTTER P, 1995, MRI EYE ORBIT
[2]   HIGH-RESOLUTION MR IMAGING OF THE WRIST AND EYE WITH SHORT TR, SHORT TE, AND PARTIAL-ECHO ACQUISITION [J].
FOO, TKF ;
SHELLOCK, FG ;
HAYES, CE ;
SCHENCK, JF ;
SLAYMAN, BE .
RADIOLOGY, 1992, 183 (01) :277-281
[3]  
HAIK BG, 1985, OPHTHALMOLOGY, V92, P1143
[4]   MALIGNANT UVEAL MELANOMA AND SIMULATING LESIONS - MR IMAGING EVALUATION [J].
MAFEE, MF ;
PEYMAN, GA ;
GRISOLANO, JE ;
FLETCHER, ME ;
SPIGOS, DG ;
WEHRLI, FW ;
RASOULI, F ;
CAPEK, V .
RADIOLOGY, 1986, 160 (03) :773-780
[5]  
MAURER J, 1994, LANCET, V342, P310
[6]   INTRAOCULAR TUMORS - EVALUATION WITH MR IMAGING [J].
PEYSTER, RG ;
AUGSBURGER, JJ ;
SHIELDS, JA ;
HERSHEY, BL ;
EAGLE, R ;
HASKIN, ME .
RADIOLOGY, 1988, 168 (03) :773-779
[7]   INCREASED CORNEAL TEMPERATURE CAUSED BY MR IMAGING OF THE EYE WITH A DEDICATED LOCAL COIL [J].
SHELLOCK, FG ;
SCHATZ, CJ .
RADIOLOGY, 1992, 185 (03) :697-699
[8]   SHORTCOMINGS AND PITFALLS OF OCULAR MRI [J].
WILMS, G ;
MARCHAL, G ;
VANFRAEYENHOVEN, L ;
DEMAEREL, P ;
VANHECKE, P ;
BAERT, AL ;
DRALANDS, G .
NEURORADIOLOGY, 1991, 33 (04) :320-325
[9]   OCULAR MR IMAGING [J].
ZIMMERMAN, RA ;
BILANIUK, LT .
RADIOLOGY, 1988, 168 (03) :875-876