Improving dose delivery accuracy with EPID in vivo dosimetry: results from a multicenter study

被引:19
作者
Esposito, M. [1 ]
Piermattei, A. [2 ]
Bresciani, S. [3 ]
Orlandini, L. C. [4 ]
Falco, M. D. [5 ]
Giancaterino, S. [5 ]
Cilla, S. [6 ]
Ianiro, A. [6 ]
Nigro, R. [7 ]
Botez, L. [3 ]
Riccardi, S. [7 ]
Fidanzio, A. [2 ]
Greco, F. [2 ]
Villaggi, E. [8 ]
Russo, S. [9 ]
Stasi, M. [10 ]
机构
[1] Azienda Sanitaria USL Toscana Ctr Florence, Med Phys Unit, SC Fis Sanitaria Firenze Empoli, Radiat Oncol Dept, Via DellAntella 58, I-50012 Florence, Italy
[2] Fdn Policlin Univ A Gemelli IRCCS, Radioterapia Oncol Ematol, UOC Fis Sanitaria, Rome, Italy
[3] Candiolo Canc Inst FPO IRCCS, Med Phys, Turin, Italy
[4] Sichuan Canc Hosp, Dept Radiat Oncol, Chengdu, Peoples R China
[5] Univ G dAnnunzio, Dipartimento Radioterapia, Chieti, Italy
[6] Fdn Ric & Cura Giovanni Paolo II, Med Phys Unit, Campobasso, Italy
[7] OGP S Camillo Lellis, Rieti, Italy
[8] AUSL Piacenza, Piacenza, Italy
[9] Azienda Sanitaria USL Toscana Ctr Florence, SC Fis Sanitaria Firenze Empoli, Florence, Italy
[10] SC Fis Sanitaria, AO Ordine Mauriziano Torino, Turin, Italy
关键词
Error detection; Quality assurance; Portal dosimetry; Online dosimetry; Online measurements;
D O I
10.1007/s00066-021-01749-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To investigate critical aspects and effectiveness of in vivo dosimetry (IVD) tests obtained by an electronic portal imaging device (EPID) in a multicenter and multisystem context. Materials and methods Eight centers with three commercial systems-SoftDiso (SD, Best Medical Italy, Chianciano, Italy), Dosimetry Check (DC, Math Resolution, LCC), and PerFRACTION (PF, Sun Nuclear Corporation, SNC, Melbourne, FL)-collected IVD results for a total of 2002 patients and 32,276 tests. Data are summarized for IVD software, radiotherapy technique, and anatomical site. Every center reported the number of patients and tests analyzed, and the percentage of tests outside of the tolerance level (OTL%). OTL% was categorized as being due to incorrect patient setup, incorrect use of immobilization devices, incorrect dose computation, anatomical variations, and unknown causes. Results The three systems use different approaches and customized alert indices, based on local protocols. For Volumetric Modulated Arc Therapy (VMAT) treatments OTL% mean values were up to 8.9% for SD, 18.0% for DC, and 16.0% for PF. Errors due to "anatomical variations" for head and neck were up to 9.0% for SD and DC and 8.0% for PF systems, while for abdomen and pelvis/prostate treatments were up to 9%, 17.0%, and 9.0% for SD, DC, and PF, respectively. The comparison among techniques gave 3% for Stereotactic Body Radiation Therapy, 7.0% (range 4.7-8.9%) for VMAT, 10.4% (range 7.0-12.2%) for Intensity Modulated Radiation Therapy, and 13.2% (range 8.8-21.0%) for 3D Conformal Radiation Therapy. Conclusion The results obtained with different IVD software and among centers were consistent and showed an acceptable homogeneity. EPID IVD was effective in intercepting important errors.
引用
收藏
页码:633 / 643
页数:11
相关论文
共 22 条
[1]  
[Anonymous], 2008, Radiotherapy Risk Profile
[2]   Comparison of two different EPID-based solutions performing pretreatment quality assurance: 2D portal dosimetry versus 3D forward projection method [J].
Bresciani, Sara ;
Poli, Matteo ;
Miranti, Anna ;
Maggio, Angelo ;
Di Dia, Amalia ;
Bracco, Christian ;
Gabriele, Pietro ;
Stasi, Michele .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 52 :65-71
[3]   EPID based in vivo dosimetry system: clinical experience and results [J].
Celi, Sofia ;
Costa, Emilie ;
Wessels, Claas ;
Mazal, Alejandro ;
Fourquet, Alain ;
Francois, Pascal .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03) :262-276
[4]   Epid-based in vivo dose verification for lung stereotactic treatments delivered with multiple breath-hold segmented volumetric modulated arc therapy [J].
Cilla, Savino ;
Ianiro, Anna ;
Craus, Mauriz O. ;
Viola, Pietro ;
Deodato, Francesco ;
Macchia, Gabriella ;
Buwenge, Milly ;
Morganti, Alessio G. ;
Valentini, Vincenzo ;
Piermattei, Angelo .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (03) :37-44
[5]   EPID-based in vivo dosimetry for stereotactic body radiotherapy of non-small cell lung tumors: Initial clinical experience [J].
Consorti, R. ;
Fidanzio, A. ;
Brainovich, V. ;
Mangiacotti, F. ;
De Spirito, M. ;
Mirri, M. A. ;
Petrucci, A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 :157-161
[6]   Clinical implementation of 3D in vivo dosimetry for abdominal and pelvic stereotactic treatments [J].
Esposito, Marco ;
Ghirelli, Alessandro ;
Pini, Silvia ;
Alpi, Paolo ;
Barca, Raffaella ;
Fondelli, Simona ;
Leonulli, Barbara Grilli ;
Paoletti, Lisa ;
Rossi, Francesca ;
Bastiani, Paolo ;
Russo, Serenella .
RADIOTHERAPY AND ONCOLOGY, 2021, 154 :14-20
[7]   Estimating dose delivery accuracy in stereotactic body radiation therapy: A review of in-vivo measurement methods [J].
Esposito, Marco ;
Villaggi, Elena ;
Bresciani, Sara ;
Cilla, Savino ;
Falco, Maria Daniela ;
Garibaldi, Cristina ;
Russo, Serenella ;
Talamonti, Cinzia ;
Stasi, Michele ;
Mancosu, Pietro .
RADIOTHERAPY AND ONCOLOGY, 2020, 149 :158-167
[8]   Characterization of EPID software for VMAT transit dosimetry [J].
Esposito, Marco ;
Bruschi, Andrea ;
Bastiani, Paolo ;
Ghirelli, Alessandro ;
Pini, Silvia ;
Russo, Serenella ;
Zatelli, Giovanna .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (04) :1021-1027
[9]   A Feasibility Study for in vivo Dosimetry Procedure in Routine Clinical Practice [J].
Falco, Maria D. ;
Giancaterino, Stefano ;
De Nicola, Andrea ;
Adorante, Nico ;
De Lorenzo, Ramon Gimenez ;
Di Tommaso, Monica ;
Vinciguerra, Annamaria ;
Trignani, Marianna ;
Perrotti, Francesca ;
Allajbej, Albina ;
Fidanzio, Andrea ;
Greco, Francesca ;
Grusio, Mattia ;
Genovesi, Domenico ;
Piermattei, Angelo .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2018, 17
[10]  
International Atomic Energy Agency, 2013, DEV PROC VIV DOS RAD