Seismic response investigation on CFDST column to steel beam blind-bolted connections

被引:45
作者
Wang, Jingfeng [1 ,2 ]
Guo, Lei [1 ]
Guo, Xiang [1 ]
Ding, Zhaodong [1 ,2 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[2] Anhui Civil Engn Struct & Mat Lab, Hefei 230009, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete-filled double skin steel tubular (CFDST); Blind bolt; Seismic performance; Simplified analytical model; Equivalent method; END-PLATE JOINTS; SKIN SHS OUTER; CHS INNER; ROTATIONAL STIFFNESS; COMPOSITE JOINTS; CONCRETE; BEHAVIOR; PERFORMANCE; HOLLOW; TESTS;
D O I
10.1016/j.jcsr.2019.04.030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The blind bolting technique, recognized as a novel solution to connect a beam to a closed section column for unavailable installation from one side, has been gradually employed in concrete filled steel tube (CFST) column to steel beam connections recently. However, unexpected failure modes including bulge of the thin-walled steel tube and anchorage failure of the blind bolt in the core concrete still existed for this type of connection, which resulted in a limited ductility and inferior strength of the connection. Therefore, a novel blind bolted joint was proposed by replacing the CFST column with the concrete-filled double skin steel tubular (CFDST) column to overcome the above problems. A series of interior joint specimens to square CFDST columns were carried out to investigate their seismic behavior. Compared with the CFST column joints, typical failure modes of the CFDST column joints were characterized. Seismic response was also analyzed in terms of the hysteretic performance, strength and stiffness degradation and energy dissipation capacity to explore the effects of the column hollow ratio and end plate type. The experimental results denoted the CFDST column to steel beam joint with blind bolts performed excellent seismic performance. Based on the equivalent method, two simplified analytical models were discussed to evaluate the initial stiffness of this type of joint The experimental and analytical results were beneficial for the application of semi-rigid connections to CFDST columns in engineering practice. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:137 / 153
页数:17
相关论文
共 34 条
[1]  
[Anonymous], 2003, GB50017-2003
[2]  
[Anonymous], 1992, ATC-24
[3]  
[Anonymous], 2005, 199318 CEN ENV
[4]   Experimental study of flush end plate beam-to-CFST column composite joints with deconstructable bolted shear connectors [J].
Ataei, Abdolreza ;
Bradford, Mark A. ;
Valipour, Hamid R. .
ENGINEERING STRUCTURES, 2015, 99 :616-630
[5]   Behaviour of steel-concrete-steel SHS X-joints under axial compression [J].
Chen, Yu ;
Feng, Ran ;
Ruan, Xianfeng .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 :469-487
[6]   Tests on concrete filled double-skin (CHS outer and SHS inner) composite short columns under axial compression [J].
Elchalakani, M ;
Zhao, XL ;
Grzebieta, R .
THIN-WALLED STRUCTURES, 2002, 40 (05) :415-441
[7]  
Eurocode 4, 1994, 1994111994 DD ENV BR
[8]   Compressive behaviour of concrete-filled double-skin sections consisting of corrugated plates [J].
Farahi, Mojtaba ;
Heidarpour, Amin ;
Zhao, Xiao-Ling ;
Al-Mahaidi, Riadh .
ENGINEERING STRUCTURES, 2016, 111 :467-477
[9]   Strength and rotational stiffness of simple connections to tubular columns using flowdrill connectors [J].
France, JE ;
Davison, JB ;
Kirby, PA .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 50 (01) :15-34
[10]   Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns [J].
Goldsworthy, H. M. ;
Gardner, A. P. .
STRUCTURAL ENGINEERING AND MECHANICS, 2006, 24 (04) :463-478