Extensive ablation during pulmonary vein antrum isolation has no adverse impact on left atrial function: An echocardiography and cine computed tomography analysis

被引:76
作者
Verma, Atul
Kilicaslan, Fethi
Adams, James R.
Hao, Steven
Beheiry, Salwa
Minor, Stephen
Ozduran, Volkan
Elayi, Samy Claude
Martin, David O.
Schweikert, Robert A.
Saliba, Walid
Thomas, James D.
Garcia, Mario
Klein, Allan
Natale, Andrea
机构
[1] Cleveland Clin Fdn, Ctr Atrial Fibrillat, Sect Pacing & Electrophysiol, Cleveland, OH 44195 USA
[2] Marin Gen Hosp, Sutter Pacific Heart Ctr, San Francisco, CA USA
关键词
left atrium; function; atrial fibrillation; ablation;
D O I
10.1111/j.1540-8167.2006.00488.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although pulmonary vein antrum isolation (PVAI) may cure atrial fibrillation (AF) and improve left atrial (LA) function, the effect of extensive LA ablation on LA function is not well known. Objective: To assess the impact of PVAI on LA function remotely postablation. Methods: Consecutive patients undergoing PVAI had either transthoracic (TTE) and transesophageal (TEE) echocardiography (n = 41) or cine EBCT (n = 26) performed preablation and 6 months postablation. Only patients with paroxysmal and persistent, but not permanent, AF were included. Imaging was done in sinus rhythm for all patients. LA diameter (LAD), LA systolic and diastolic areas, and left atrial fractional area change (LFAC) were assessed by TTE. Transmitral (TMF), left atrial appendage (LAA), and pulmonary venous (PVF) Doppler flows were measured by TEE. Peak A on TMF, LAA peak emptying velocity (LAAF), and peak A reversal (AR) on PVF were used as surrogates of LA contractile function. Peak S on PV flow was used as a surrogate of reservoir function. LA areas, volumes, and LA ejection fraction (LAEF) were measured from cine EBCT. Results: Mean radiofrequency ablation time was 45 +/- 21 minutes. All four PVs were isolated for all patients; there were no cases of PV stenosis. Echocardiography revealed a significant reduction in LAD and LA areas post-PVAI. Both peak A and peak AR were also higher post, while other variables showed strong trends toward improvement. In the subset of patients with persistent AF, post-PVAI improvements were seen in LA size, peak A, and even peak S (P = 0.04). Cine EBCT showed a significant decrease in both LA areas and volumes post-PVAI. There was also a significant improvement in LAEF post-PVAI from 17 +/- 6% to 22 +/- 5% (P = 0.01). Conclusion: Extensive ablation during PVAI does not cause deterioration in LA function, and may cause long-term improvement, especially in patients with higher AF burden.
引用
收藏
页码:741 / 746
页数:6
相关论文
共 22 条
  • [1] Left and right atrial transport function after the maze procedure for atrial fibrillation: An echocardiographic Doppler follow-up study
    Albirini, A
    Scalia, GM
    Murray, RD
    Chung, MK
    McCarthy, PM
    Griffin, BP
    Arheart, KL
    Klein, AL
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (09) : 937 - 945
  • [2] Electrical, contractile and structural remodeling during atrial fibrillation
    Allessie, M
    Ausma, J
    Schotten, U
    [J]. CARDIOVASCULAR RESEARCH, 2002, 54 (02) : 230 - 246
  • [3] Time course of left atrial mechanical recovery after linear lesions: Normal sinus rhythm versus a chronic atrial fibrillation dog model
    Avitall, B
    Urbonas, A
    Urboniene, D
    Millard, S
    Helms, R
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (12) : 1397 - 1406
  • [4] Predictors for atrial transport function after mini-maze operation
    Bauer, EP
    Szalay, ZA
    Brandt, RR
    Pitschner, HF
    Bachmann, G
    Brunner-La Rocca, HP
    Klövekorn, WP
    [J]. ANNALS OF THORACIC SURGERY, 2001, 72 (04) : 1251 - 1254
  • [5] Short-term effect of atrial fibrillation on atrial contractile function in humans
    Daoud, EG
    Marcovitz, P
    Knight, BP
    Goyal, R
    Man, KC
    Strickberger, SA
    Armstrong, WF
    Morady, F
    [J]. CIRCULATION, 1999, 99 (23) : 3024 - 3027
  • [6] TRANSESOPHAGEAL ECHOCARDIOGRAPHY BEFORE AND DURING DIRECT-CURRENT CARDIOVERSION OF ATRIAL-FIBRILLATION - EVIDENCE FOR ATRIAL STUNNING AS A MECHANISM OF THROMBOEMBOLIC COMPLICATIONS
    FATKIN, D
    KUCHAR, DL
    THORBURN, CW
    FENELEY, MP
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) : 307 - 316
  • [7] FEINBERG MS, 1994, CIRCULATION, V90, P285
  • [8] ALTERED LEFT ATRIAL COMPLIANCE AFTER ATRIAL APPENDECTOMY - INFLUENCE ON LEFT ATRIAL AND VENTRICULAR FILLING
    HOIT, BD
    SHAO, YF
    TSAI, LM
    PATEL, R
    GABEL, M
    WALSH, RA
    [J]. CIRCULATION RESEARCH, 1993, 72 (01) : 167 - 175
  • [9] Atrial stunning: basics and clinical considerations
    Khan, IA
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 92 (2-3) : 113 - 128
  • [10] Atrial mechanical performance after internal and external cardioversion of atrial fibrillation - An echocardiographic study
    Lehmann, G
    Horcher, J
    Dennig, K
    Plewan, A
    Ulm, K
    Alt, E
    [J]. CHEST, 2002, 121 (01) : 13 - 18