Combination of structured illumination and single molecule localization microscopy in one setup

被引:42
作者
Rossberger, Sabrina [1 ,2 ]
Best, Gerrit [1 ,2 ]
Baddeley, David [3 ,4 ]
Heintzmann, Rainer [5 ,6 ,7 ]
Birk, Udo [1 ,8 ]
Dithmar, Stefan [2 ]
Cremer, Christoph [1 ,8 ,9 ]
机构
[1] Heidelberg Univ, Kirchhoff Inst Phys, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Dept Ophthalmol, D-69120 Heidelberg, Germany
[3] Univ Auckland, Dept Physiol, Auckland, New Zealand
[4] Yale Univ, Sch Med, Dept Cell Biol, New Haven, CT 06510 USA
[5] Univ Jena, Inst Phys Chem, D-07743 Jena, Germany
[6] Inst Photon Technol, Jena, Germany
[7] Kings Coll London, Randall Div, London, England
[8] Inst Mol Biol, Mainz, Germany
[9] Heidelberg Univ, Inst Pharm & Mol Biotechnol, D-69120 Heidelberg, Germany
关键词
super-resolution microscopy; single molecule localization microscopy (SMLM); structured illumination microscopy (SIM); imaging; SPDM; OPTICAL RECONSTRUCTION MICROSCOPY; PATTERNED EXCITATION MICROSCOPY; FIELD FLUORESCENCE NANOSCOPY; RESOLUTION LIMIT; DIFFRACTION-LIMIT; LIGHT-MICROSCOPY; LIVE CELLS; SUPERRESOLUTION; IMPROVEMENT; PROBES;
D O I
10.1088/2040-8978/15/9/094003
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Understanding the positional and structural aspects of biological nanostructures simultaneously is as much a challenge as a desideratum. In recent years, highly accurate (20 nm) positional information of optically isolated targets down to the nanometer range has been obtained using single molecule localization microscopy (SMLM), while highly resolved (100 nm) spatial information has been achieved using structured illumination microscopy (SIM). In this paper, we present a high-resolution fluorescence microscope setup which combines the advantages of SMLM with SIM in order to provide high-precision localization and structural information in a single setup. Furthermore, the combination of the wide-field SIM image with the SMLM data allows us to identify artifacts produced during the visualization process of SMLM data, and potentially also during the reconstruction process of SIM images. We describe the SMLM-SIM combo and software, and apply the instrument in a first proof-of-principle to the same region of H3K293 cells to achieve SIM images with high structural resolution (in the 100 nm range) in overlay with the highly accurate position information of localized single fluorophores. Thus, with its robust control software, efficient switching between the SMLM and SIM mode, fully automated and user-friendly acquisition and evaluation software, the SMLM-SIM combo is superior over existing solutions.
引用
收藏
页数:13
相关论文
共 54 条
  • [1] Ach T, 2010, OPHTHALMOLOGE, V107, P1037, DOI 10.1007/s00347-010-2183-y
  • [2] Autofluorescence imaging of human RPE cell granules using structured illumination microscopy
    Ach, Thomas
    Best, Gerrit
    Rossberger, Sabrina
    Heintzmann, Rainer
    Cremer, Christoph
    Dithmar, Stefan
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (08) : 1141 - 1144
  • [3] 4D Super-Resolution Microscopy with Conventional Fluorophores and Single Wavelength Excitation in Optically Thick Cells and Tissues
    Baddeley, David
    Crossman, David
    Rossberger, Sabrina
    Cheyne, Juliette E.
    Montgomery, Johanna M.
    Jayasinghe, Isuru D.
    Cremer, Christoph
    Cannell, Mark B.
    Soeller, Christian
    [J]. PLOS ONE, 2011, 6 (05):
  • [4] Three-dimensional sub-100 nm super-resolution imaging of biological samples using a phase ramp in the objective pupil
    Baddeley, David
    Cannell, Mark B.
    Soeller, Christian
    [J]. NANO RESEARCH, 2011, 4 (06) : 589 - 598
  • [5] Visualization of Localization Microscopy Data
    Baddeley, David
    Cannell, Mark B.
    Soeller, Christian
    [J]. MICROSCOPY AND MICROANALYSIS, 2010, 16 (01) : 64 - 72
  • [6] Light-induced Dark States of Organic Fluochromes Enable 30 nm Resolution Imaging in Standard Media
    Baddeley, David
    Jayasinghe, Izzy
    Cremer, Christoph
    Cannell, Mark B.
    Soeller, Christian
    [J]. BIOPHYSICAL JOURNAL, 2009, 96 (02) : L22 - L24
  • [7] Multicolor super-resolution imaging with photo-switchable fluorescent probes
    Bates, Mark
    Huang, Bo
    Dempsey, Graham T.
    Zhuang, Xiaowei
    [J]. SCIENCE, 2007, 317 (5845) : 1749 - 1753
  • [8] Structured illumination microscopy of autofluorescent aggregations in human tissue
    Best, Gerrit
    Amberger, Roman
    Baddeley, David
    Ach, Thomas
    Dithmar, Stefan
    Heintzmann, Rainer
    Cremer, Christoph
    [J]. MICRON, 2011, 42 (04) : 330 - 335
  • [9] Imaging intracellular fluorescent proteins at nanometer resolution
    Betzig, Eric
    Patterson, George H.
    Sougrat, Rachid
    Lindwasser, O. Wolf
    Olenych, Scott
    Bonifacino, Juan S.
    Davidson, Michael W.
    Lippincott-Schwartz, Jennifer
    Hess, Harald F.
    [J]. SCIENCE, 2006, 313 (5793) : 1642 - 1645
  • [10] Two-color far-field fluorescence nanoscopy based on photoswitchable emitters
    Bock, H.
    Geisler, C.
    Wurm, C. A.
    Von Middendorff, C.
    Jakobs, S.
    Schoenle, A.
    Egner, A.
    Hell, S. W.
    Eggeling, C.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 88 (02): : 161 - 165