Computational optimization of a novel solid-state sensor for stable assay of isoxsuprine hydrochloride in the presence of its nephrotoxic/hepatotoxic photothermal degradation products: application in different sampling matrices

被引:11
作者
Kelani, Khadiga M. [1 ,2 ]
Elzanfaly, Eman S. [1 ]
Halim, Michael K. [3 ]
Saad, Ahmed S. [1 ,3 ,4 ]
机构
[1] Cairo Univ, Fac Pharm, Analyt Chem Dept, El Kasr El Aini St, Cairo, Egypt
[2] Modern Technol & Informat Univ, Fac Pharm, Analyt Chem Dept, Cairo, Egypt
[3] October 6 Univ, Fac Pharm, Analyt Chem Dept, 6 October City, Egypt
[4] Badr Univ Cairo BUC, Sch Pharm & Pharmaceut Ind, Pharmaceut Chem Dept, Cairo 11829, Egypt
关键词
ION-SELECTIVE ELECTRODES; INJECTION POTENTIOMETRIC DETERMINATION; PROPYL BETA-CYCLODEXTRIN; MEMBRANE ELECTRODES; COEFFICIENTS; IONOPHORES; CALIXARENE; DRUGS; PURE;
D O I
10.1039/d0nj03482g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The pharmaceutical industry carries out analysis throughout the different stages of production to guarantee safety, potency, and purity. This work introduces a novel solid-state-potentiometric sensor for the selective assay of isoxsuprine hydrochloride (ISX) in the presence of its nephrotoxic and hepatotoxic photothermal degradation products. Preliminary studies specified the critical factors affecting the sensor performance. A two-level four-factor fractional factorial experimental design was constructed to evaluate the main effects and interactions among the specified factors. Factors included categorical factors (such as the ion-exchanger, binder, and ionophore), and numerical factors, such as the relative amounts of the matrix components. Eight sensors containing different levels of the studied factors were studied and outputs describing the sensor performance were estimated, such as the Nernstian slope, detection limit, and correlation coefficient. RStudio (R) software was used to calculate the prediction model used for the evidence-based selection of the optimum sensor composition. The optimized sensor proved a slope of 59.71 mV per decade, a limit of detection of 2.5 x 10(-6)M, and a correlation coefficient approaching unity within the concentration range of 3.38 x 10(-6)-1 x 10(-2)M. The sensor expressed a selective response to ISX in the presence of four nephrotoxic and hepatotoxic photothermal degradation products and common ionic contaminants. After ICH validation, the method proved its applicability throughout the different phases of pharmaceutical production (raw material, formulation, and biological samples). The fast and stable sensor response enabled the real-time inline dissolution testing of ISX tablets. The method was experimentally and statistically compared with the official USP dissolution method.
引用
收藏
页码:15260 / 15269
页数:10
相关论文
共 42 条
[1]   DETERMINATION OF DIPHENYLPYRALINE HYDROCHLORIDE IN PURE SOLUTIONS AND PHARMACEUTICAL PREPARATIONS USING ION SELECTIVE ELECTRODES UNDER BATCH AND FIA CONDITIONS [J].
Abdel-Ghani, Nour Tawfik ;
Hussein, Salwa Hamed .
ANALYTICAL LETTERS, 2010, 43 (04) :582-602
[2]   Flow injection potentiometric determination of pipazethate hydrochloride [J].
Abdel-Ghani, NT ;
Shoukry, AF ;
El Nashar, RM .
ANALYST, 2001, 126 (01) :79-85
[3]   A comparative study of solid and liquid inner contact benzalkonium chloride ion-selective electrode membranes [J].
Abu Shawish, Hazem M. ;
Khedr, Abdalla M. ;
Abed-Almonem, Khalid I. ;
Gaber, M. .
TALANTA, 2012, 101 :211-219
[4]  
[Anonymous], 1989, MONOGRAPHS SUPRAMOLE
[5]  
[Anonymous], 2009, BRIT PHARMACOPOEIA S
[6]  
[Anonymous], 2009, US PHARM USP32 NATL
[7]   PROPERTIES OF PVC BASED MEMBRANES USED IN ION-SELECTIVE ELECTRODES [J].
ARMSTRONG, RD ;
HORVAI, G .
ELECTROCHIMICA ACTA, 1990, 35 (01) :1-7
[8]   Experimental design of membrane sensor for selective determination of phenazopyridine hydrochloride based on computational calculations [J].
Attia, Khalid A. M. ;
El-Abasawi, Nasr M. ;
Abdel-Azim, Ahmed H. .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 61 :773-781
[9]   Electroanalysis with Membrane Electrodes and Liquid-Liquid Interfaces [J].
Bakker, Eric .
ANALYTICAL CHEMISTRY, 2016, 88 (01) :395-413
[10]   POLYMER MEMBRANE ELECTRODES .2. POTASSIUM ION-SELECTIVE MEMBRANE ELECTRODE [J].
BAUM, G ;
LYNN, M .
ANALYTICA CHIMICA ACTA, 1973, 65 (02) :393-403