Diagnostic accuracy of clinical tests of the hip: a systematic review with meta-analysis

被引:62
|
作者
Reiman, Michael P. [1 ]
Goode, Adam P. [1 ]
Hegedus, Eric J. [2 ]
Cook, Chad E. [3 ]
Wright, Alexis A. [2 ]
机构
[1] Duke Univ, Sch Med, Durham, NC 27705 USA
[2] High Point Univ, High Point, NC USA
[3] Walsh Univ, North Canton, OH USA
关键词
PHYSICAL-EXAMINATION TESTS; MAGNETIC-RESONANCE ARTHROGRAPHY; ACETABULAR LABRAL TEARS; RECOGNIZING VASCULAR CAUSES; FEMOROACETABULAR IMPINGEMENT; DIFFERENTIAL-DIAGNOSIS; COMPUTED-TOMOGRAPHY; STRESS-FRACTURES; LEG COMPLAINTS; FEMORAL-SHAFT;
D O I
10.1136/bjsports-2012-091035
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background Hip Physical Examination (HPE) tests have long been used to diagnose a myriad of intra-and extra-articular pathologies of the hip joint. Useful clinical utility is necessary to support diagnostic imaging and subsequent surgical decision making. Objective Summarise and evaluate the current research and utility on the diagnostic accuracy of HPE tests for the hip joint germane to sports related injuries and pathology. Methods A computer-assisted literature search of MEDLINE, CINHAL and EMBASE databases (January 1966 to January 2012) using keywords related to diagnostic accuracy of the hip joint. This systematic review with meta-analysis utilised the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for the search and reporting phases of the study. Der-Simonian and Laird random effects models were used to summarise sensitivities (SN), specificities (SP), likelihood ratios and diagnostic OR. Results The employed search strategy revealed 25 potential articles, with 10 demonstrating high quality. Fourteen articles qualified for meta-analysis. The meta-analysis demonstrated that most tests possess weak diagnostic properties with the exception of the patellar-pubic percussion test, which had excellent pooled SN 95 (95% CI 92 to 97%) and good specificity 86 (95% CI 78 to 92%). Conclusion Several studies have investigated pathology in the hip. Few of the current studies are of substantial quality to dictate clinical decision-making. Currently, only the patellar-pubic percussion test is supported by the data as a stand-alone HPE test. Further studies involving high quality designs are needed to fully assess the value of HPE tests for patients with intra- and extra-articular hip dysfunction.
引用
收藏
页码:893 / 902
页数:11
相关论文
共 50 条
  • [1] Diagnostic accuracy of clinical tests for the diagnosis of hip femoroacetabular impingement/labral tear: a systematic review with meta-analysis
    Reiman, M. P.
    Goode, A. P.
    Cook, C. E.
    Holmich, P.
    Thorborg, K.
    BRITISH JOURNAL OF SPORTS MEDICINE, 2015, 49 (12) : 811
  • [2] Diagnostic Accuracy of Clinical Tests for Subacromial Impingement Syndrome: A Systematic Review and Meta-Analysis
    Alqunaee, Marwan
    Galvin, Rose
    Fahey, Tom
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (02): : 229 - 236
  • [3] Accuracy of diagnostic tests for acute diverticulitis that are feasible in primary care: a systematic review and meta-analysis
    Vijfschagt, Natasja D.
    de Boer, Michiel R.
    Berger, Marjolein Y.
    Burger, Huibert
    Holtman, Gea A.
    FAMILY PRACTICE, 2024, 41 (01) : 1 - 8
  • [4] The validity and accuracy of clinical diagnostic tests used to detect labral pathology of the hip: A systematic review
    Burgess, Roanna M.
    Rushton, Alison
    Wright, Chris
    Daborn, Cathryn
    MANUAL THERAPY, 2011, 16 (04) : 318 - 326
  • [5] Diagnostic accuracy of adrenal imaging for subtype diagnosis in primary aldosteronism: systematic review and meta-analysis
    Zhou, Yaqiong
    Wang, Dan
    Jiang, Licheng
    Ran, Fei
    Chen, Sichao
    Zhou, Peng
    Wang, Peijian
    BMJ OPEN, 2020, 10 (12):
  • [6] Diagnostic accuracy of functional imaging modalities for chondrosarcoma: A systematic review and meta-analysis
    Jo, I
    Gould, D.
    Schlicht, S.
    Taubman, K.
    Choong, P.
    JOURNAL OF BONE ONCOLOGY, 2019, 19
  • [7] Diagnostic Accuracy of CT for the Detection of Hepatic Steatosis: A Systematic Review and Meta-Analysis
    Haghshomar, Maryam
    Antonacci, Dominic
    Smith, Andrew D.
    Thaker, Sarang
    Miller, Frank H.
    Borhani, Amir A.
    RADIOLOGY, 2024, 313 (02)
  • [8] Diagnostic Accuracy of Imaging Findings in Pleural Empyema: Systematic Review and Meta-Analysis
    Zettinig, Desiree
    D'Antonoli, Tugba Akinci
    Wilder-Smith, Adrian
    Bremerich, Jens
    Roth, Jan A.
    Sexauer, Raphael
    JOURNAL OF IMAGING, 2022, 8 (01)
  • [9] "The accuracy of the EOS imaging system to assess hip abnormalities in adolescents and adults:" a systematic review and meta-analysis
    Alghamdi, Ahmed
    Madan, Sanjeev
    Shuweihdi, Farag
    Offiah, Amaka C.
    SKELETAL RADIOLOGY, 2024, 53 (01) : 29 - 42
  • [10] Diagnostic Accuracy of Computed Tomography to Exclude Pheochromocytoma: A Systematic Review, Meta-analysis, and Cost Analysis
    Buitenwerf, Edward
    Berends, Annika M. A.
    van Asselt, Antoinette D., I
    Korteweg, Tijmen
    Greuter, Marcel J. W.
    Veeger, Nic J. M.
    Links, Thera P.
    Dullaart, Robin P. F.
    Kerstens, Michiel N.
    MAYO CLINIC PROCEEDINGS, 2019, 94 (10) : 2040 - 2052