Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography

被引:116
作者
Noori, Shahab [1 ,2 ,3 ,4 ]
Drabu, Benazir [4 ]
Soleymani, Sadaf [1 ,2 ,3 ,5 ]
Seri, Istvan [1 ,2 ,3 ]
机构
[1] Univ So Calif, Childrens Hosp Los Angeles, Div Neonatol, Los Angeles, CA 90027 USA
[2] Univ So Calif, Childrens Hosp Los Angeles, Ctr Fetal & Neonatal Med, Dept Pediat, Los Angeles, CA 90027 USA
[3] Univ So Calif, LAC USC Med Ctr, Keck Sch Med, Los Angeles, CA 90027 USA
[4] Univ Oklahoma, Hlth Sci Ctr, Dept Pediat, Sect Neonatal Perinatal Med,Childrens Hosp, Oklahoma City, OK 73190 USA
[5] Univ So Calif, Viterbi Sch Engn, Dept Biomed Engn, Los Angeles, CA 90027 USA
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 2012年 / 97卷 / 05期
关键词
PATENT DUCTUS-ARTERIOSUS; THERMODILUTION; PRECISION; CHILDREN; DOPPLER; PIGLETS;
D O I
10.1136/fetalneonatal-2011-301090
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective Electrical velocimetry (EV) is a non-invasive method of continuous left cardiac output monitoring based on measurement of thoracic electrical bioimpedance. The objective was to validate EV by investigating the agreement in cardiac output measurements performed by EV and echocardiography. Design In this prospective observational study, left ventricular output (LVO) was simultaneously measured by EV (LVOev) using Aesculon and by echocardiography (LVOecho) in healthy term neonates during the first 2 postnatal days. To determine the agreement between the two methods, we calculated the bias (mean difference) and precision (1.96xSD of the difference). As LVOecho has its own limitations, the authors also calculated the 'true precision' of EV adjusted for echocardiography as the reference method. Results The authors performed 115 paired measurements in 20 neonates. LVOev and LVOecho were similar (534 +/- 105 vs 538 +/- 105 ml/min, p=0.7). The bias and precision of EV were -4 and 234 ml/min, respectively. The authors found the true precision of EV to be similar to the precision of echocardiography (31.6% vs 30%, respectively). There was no difference in bias and precision between the measurements obtained in patients with or without a haemodynamically significant patent ductus arteriosus. Conclusions EV is as accurate in measuring LVO as echocardiography and the variation in the agreement between EV and echocardiography among the individual subjects reflects the limitations of both techniques.
引用
收藏
页码:F340 / F343
页数:4
相关论文
共 16 条
[1]   NON-INVASIVE PULSED DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN NEONATES AND CHILDREN [J].
ALVERSON, DC ;
ELDRIDGE, M ;
DILLON, T ;
YABEK, SM ;
BERMAN, W .
JOURNAL OF PEDIATRICS, 1982, 101 (01) :46-50
[2]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[3]   Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output [J].
Cecconi, Maurizio ;
Rhodes, Andrew ;
Poloniecki, Jan ;
Della Rocca, Giorgio ;
Grounds, R. Michael .
CRITICAL CARE, 2009, 13 (01)
[4]   Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature [J].
Chew, MS ;
Poelaert, J .
INTENSIVE CARE MEDICINE, 2003, 29 (11) :1889-1894
[5]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[6]   Cardiac output measurement using an ultrasound dilution method: A validation study in ventilated piglets [J].
de Boode, Willem P. ;
van Heijst, Arno F. J. ;
Hopman, Jeroen C. W. ;
Tanke, Ronald B. ;
van der Hoeven, Hans G. ;
Liem, Kian D. .
PEDIATRIC CRITICAL CARE MEDICINE, 2010, 11 (01) :103-108
[7]   Clinical monitoring of systemic hemodynamics in critically ill newborns [J].
de Boode, Willem-Pieter .
EARLY HUMAN DEVELOPMENT, 2010, 86 (03) :137-141
[8]   Cardiac output monitoring in newborns [J].
de Boode, Willem-Pieter .
EARLY HUMAN DEVELOPMENT, 2010, 86 (03) :143-148
[9]   EARLY ECHOCARDIOGRAPHIC PREDICTION OF SYMPTOMATIC PATENT DUCTUS-ARTERIOSUS IN PRETERM INFANTS UNDERGOING MECHANICAL VENTILATION [J].
KLUCKOW, M ;
EVANS, N .
JOURNAL OF PEDIATRICS, 1995, 127 (05) :774-779
[10]  
KUBICEK WG, 1966, AEROSPACE MED, V37, P1208