Removal of Ocular Artifact from EEG Using Constrained ICA

被引:3
|
作者
Huang, Lu [1 ]
Wang, Hong
Wang, Yu [1 ]
机构
[1] Northeastern Univ, Sino Dutch Biomed & Informat Engn Sch, Shenyang 110819, Peoples R China
关键词
Blind source separation (BSS); constrained independent component analysis (CICA); Electroencephalogram (EEG); Artifact removal; Reference signal; INDEPENDENT COMPONENT ANALYSIS;
D O I
10.4028/www.scientific.net/AEF.2-3.105
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Ocular artifacts are the most important form of interferences in EEG signals. Before analyzed, EEG signals should be pretreated by removal of ocular artifacts. CICA is an excellent approach to separate the desired source signals. But, the choice of reference signals is crucial. In this paper, we adopted CICA to separate ocular artifact from EEG, using a different method from Lu to build the reference signals, which can avoid the subjectivity during the operation. It was proved to be effective.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 50 条
  • [1] Automatic Removal of Ocular Artifact from EEG with DWT and ICA Method
    Li, Mingai
    Cui, Yan
    Yang, Jinfu
    APPLIED MATHEMATICS & INFORMATION SCIENCES, 2013, 7 (02): : 809 - 816
  • [2] Ocular Artifact Removal from EEG Using ANFIS
    Chen, Wei
    Wang, Ze
    Lao, Ka Fai
    Wan, Feng
    2014 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ-IEEE), 2014, : 2410 - 2417
  • [3] Effects of ocular artifact removal through ICA decomposition on EEG phase
    Montefusco-Siegmund, Rodrigo
    Maldonado, Pedro E.
    Devia, Christ
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 1374 - 1377
  • [4] Comparison of Three ICA Algorithms for Ocular Artifact Removal from TMS-EEG Recordings
    Lyzhko, E.
    Hamid, L.
    Makhortykh, S.
    Moliadze, V.
    Siniatchkin, M.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 1926 - 1929
  • [5] Removal of ocular artifact from the EEG: a review
    Croft, RJ
    Barry, RJ
    NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2000, 30 (01): : 5 - 19
  • [6] Blinking artifact removal in cognitive EEG data using ICA
    Li, Ruijiang
    Principe, Jose C.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3675 - +
  • [7] Using ICA for removal of ocular artifacts in EEG recorded from blind subjects
    Flexer, A
    Bauer, H
    Pripfl, J
    Dorffner, G
    NEURAL NETWORKS, 2005, 18 (07) : 998 - 1005
  • [8] A framework for evaluating ICA methods of artifact removal from multichannel EEG
    Glass, KA
    Frishkoff, GA
    Frank, RM
    Davey, C
    Dien, J
    Malony, AD
    Tucker, DM
    INDEPENDENT COMPONENT ANALYSIS AND BLIND SIGNAL SEPARATION, 2004, 3195 : 1033 - 1040
  • [9] EEG Artifact Removal by Bayesian Deep Learning & ICA
    Lee, Sangmin S.
    Lee, Kiwon
    Kang, Guiyeom
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 932 - 935
  • [10] Removal of Ocular Artifacts from EEG Signals Using ICA-RLS in BCI
    Yang, Banghua
    He, Liangfei
    2014 IEEE WORKSHOP ON ELECTRONICS, COMPUTER AND APPLICATIONS, 2014, : 544 - 547