Prospective Randomized Trial of Transthoracic Echocardiography Versus Transesophageal Echocardiography for Assessment and Guidance of Transcatheter Closure of Atrial Septal Defects in Children Using the Amplatzer Septal Occluder

被引:52
作者
Bartakian, Sergio
El-Said, Howaida G.
Printz, Beth
Moore, John W.
机构
[1] Univ Calif San Diego, San Diego Sch Med, Div Cardiol, Dept Pediat, San Diego, CA 92123 USA
[2] Univ Calif San Diego, Rady Childrens Hosp, Div Cardiol, Dept Pediat, San Diego, CA 92123 USA
关键词
atrial septal defect; defect sizing; device closure; echocardiogram; INTRACARDIAC ECHOCARDIOGRAPHY; DEVICE CLOSURE; ADULTS;
D O I
10.1016/j.jcin.2013.05.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study sought to determine whether transthoracic echocardiography (TTE) can provide safety and efficacy equivalent to transesophageal echocardiography (TEE) for assessment and guidance of transcatheter atrial septal defect (ASD) closure in pediatric patients. Methods We performed a prospective randomized trial of ASD closure using the Amplatzer septal occluder (ASO) from March 2008 to April 2012. Inclusion criteria were isolated secundum ASD, age 2 to 18 years, and adequate TTE windows. Forty patients were enrolled and randomized to either TEE or TTE. In the TEE group, we used "stop flow" balloon sizing to determine device size. In the TTE group, we used the average ASD diameter times 1.2 (scaled). Patients were followed up to 1 year. Results Patient general and hemodynamic characteristics were similar in both groups. Procedural success was 100% in both groups. The average TEE stop flow diameter was similar to the scaled TTE diameter (15.35 +/- 4.62 mm vs. 16.57 +/- 5.47 mm; p = 0.46). Device size (16.0 +/- 4.94 mm vs. 16.37 +/- 5.05 mm, p = 0.82) and ratio of device to defect size (1.0 +/- 0.06 vs. 0.99 +/- 0.03, p = 0.52) were also similar. Total procedure (70.6 +/- 22.98 min vs. 51.1 +/- 17.61 min, p = 0.005), room (126.8 +/- 28.41 min vs. 95.7 +/- 20.53 min, p = 0.0004), and fluoroscopy (13.6 +/- 6.17 min vs. 8.9 +/- 8.45 min, p = 0.007) times were all significantly shorter in the TTE group. Neither group had significant complications during the procedure nor in follow-up. Rates of shunt resolution were similar between groups. Conclusions This study suggests that in selected pediatric patients, use of TTE is as efficacious and safe as TEE for assessment and guidance of ASD occlusion using the ASO. TTE also may offer the additional safety benefit of reduced fluoroscopy exposure. (C) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:974 / 980
页数:7
相关论文
共 19 条
[1]   Comparison of costs of intracardiac echocardiography and transesophageal echocardiography in monitoring percutaneous device closure of atrial septal defect in children and adults [J].
Alboliras, ET ;
Hijazi, ZM .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (05) :690-692
[2]   Transcatheter closure of secundum atrial septal defects [J].
Amin, Zahid .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (05) :778-787
[3]  
[Anonymous], 1996, ANESTHESIOLOGY, V84, P986
[4]   Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect [J].
Boccalandro, F ;
Baptista, E ;
Muench, A ;
Carter, C ;
Smalling, RW .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (04) :437-440
[5]   Transcatheter atrial septal defect closure: Modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder [J].
Carlson, KM ;
Justino, H ;
O'Brien, RE ;
Dimas, VV ;
Leonard, GT ;
Pignatelli, RH ;
Mullins, CE ;
Smith, EO ;
Grifka, RG .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (03) :390-396
[6]   Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults - Results of a multicenter nonrandomized trial [J].
Du, ZD ;
Hijazi, ZM ;
Kleinman, CS ;
Silverman, NH ;
Larnitz, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (11) :1836-1844
[7]   Community Use of the Amplatzer Atrial Septal Defect Occluder: Results of the Multicenter MAGIC Atrial Septal Defect Study [J].
Everett, Allen D. ;
Jennings, Jacky ;
Sibinga, Erica ;
Owada, Carl ;
Lim, D. Scott ;
Cheatham, John ;
Holzer, Ralf ;
Ringewald, Jeremy ;
Bandisode, Rani ;
Ringel, Richard .
PEDIATRIC CARDIOLOGY, 2009, 30 (03) :240-247
[8]   TRANSESOPHAGEAL ECHOCARDIOGRAPHIC GUIDANCE OF TRANSCATHETER CLOSURE OF ATRIAL SEPTAL-DEFECT [J].
HELLENBRAND, WE ;
FAHEY, JT ;
MCGOWAN, FX ;
WELTIN, GG ;
KLEINMAN, CS .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (02) :207-213
[9]   Results of the US multicenter pivotal study of the HELEX septal occluder for percutaneous closure of secundum atrial septal defects [J].
Jones, Thomas K. ;
Latson, Larry A. ;
Zahn, Evan ;
Fleishman, Craig E. ;
Jacobson, Joth ;
Vincent, Robert ;
Kanter, Kirk .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (22) :2215-2221
[10]   Transthoracic echocardiographic guidance of transcatheter atrial septal defect closure [J].
Kardon, RE ;
Sokoloski, MC ;
Levi, DS ;
Perry, JS ;
Schneider, DJ ;
Allada, V ;
Moore, JW .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (02) :256-260