Initial Results of the MINDView PET Insert Inside the 3T mMR

被引:50
作者
Gonzalez, Antonio J. [1 ]
Gonzalez-Montoro, Andrea [1 ]
Vidal, Luis F. [1 ]
Barbera, Julio [2 ]
Aussenhofer, Sebastian [3 ]
Hernandez, Liczandro [1 ]
Moliner, Laura [1 ]
Sanchez, Filomeno [1 ]
Correcher, Carlos [4 ]
Pincay, Edwin J. [1 ]
Canizares, Gabriel [1 ]
Lamprou, Efthymios [1 ]
Sanchez, Sebastian [1 ]
Catret, Juan, V [2 ]
Jimenez-Serrano, Santiago [2 ]
Cabello, Jorge [5 ]
Schwaiger, Markus [5 ]
Iborra, Amadeo [6 ]
Merlin, Thibaut [6 ]
Visvikis, Dimitris [6 ]
Benlloch, Jose M. [1 ]
机构
[1] Univ Politecn Valencia, Inst Instrumentac Imagen Mol, Ctr Mixto, CSIC, E-46022 Valencia, Spain
[2] Oncovision, Valencia 46022, Spain
[3] NORAS MRI Prod GmbH, D-97204 Hochberg, Germany
[4] Bruker NMI, Valencia 46013, Spain
[5] Tech Univ Munich, Klinikum Rechts Isar, Nukl Med, D-81675 Munich, Germany
[6] INSERM, LaTIM, F-29609 Brest, France
基金
欧洲研究理事会;
关键词
Brain positron emission tomography (PET); hybrid PET/MR insert; molecular imaging; monolithic crystals; silicon photomultipliers (SiPM); BRAIN; PERFORMANCE; DETECTOR; FEASIBILITY; SIPM;
D O I
10.1109/TRPMS.2018.2866899
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Hybrid molecular and anatomical imaging devices, especially when simultaneously working, have shown to provide advantages over sequential acquisitions. In particular, we present in this preliminary study, the working performance of a brain positron emission tomography (PET) insert, within a 3T magnetic resonance imaging (MRI) system. To our knowledge, this is the largest PET system based on monolithic LYSO blocks. It consists of 60 scintillator blocks of 50 mm x 50 mm x 20 mm arranged in 3 rings of 20 detector modules each. An effective field of view (FOV) of 240 mm in diameter and 154 mm axially is defined. The crystals included a retroreflector layer at the entrance face, and are coupled to custom arrays of 12 x 12 silicon photomultipliers (SiPM), 3 mm x 3 mm each. Frontend electronics provide X and Y projections of the scintillation light by sampling each row and column of the SiPM arrays. The insert is thermally stabilized by using temperature-controlled air to about 27 degrees C. The PET insert has been installed at the Klinikum rechts der Isar (Munich) and tested within the whole-body Siemens biograph mMR, a 3T MRI combined with a PET scanner. A system sensitivity of almost 7% for an energy window of 350-650 keV was measured using a small size source at the center of the FOV (CFOV). Current system evaluation showed a spatial resolution at the CFOV of 1.7 mm using iterative algorithms, being below 2 mm within a centered diameter of 120 mm. Rods of a small Derenzo phantom of 2.5 mm were clearly resolved, independently of all tested MRI sequences including echo-planar imaging, ultrashort time echo, MPrage, and T2-flair or arterial spin labeling. The PET insert did not show any count rate degradation also under those sequences for a variety of MR imaging acquisitions.
引用
收藏
页码:343 / 351
页数:9
相关论文
共 23 条
[11]  
Gonzalez-Montoro A., 2017, P IEEE MED IM C
[12]   Performance Study of a Large Monolithic LYSO PET Detector with Accurate Photon DOI Using Retroreflector Layers [J].
Gonzalez-Montoro, Andrea ;
Aguilar, Albert ;
Canizares, Gabriel ;
Conde, Pablo ;
Hernandez, Liczandro ;
Vidal, Luis F. ;
Galasso, Matteo ;
Fabbri, Andrea ;
Sanchez, Filomeno ;
Benlloch, Jose M. ;
Gonzalez, Antonio J. .
IEEE Transactions on Radiation and Plasma Medical Sciences, 2017, 1 (03) :229-237
[13]   High resolution BrainPET combined with simultaneous MRI [J].
Herzog, H. ;
Langen, K. -J. ;
Weirich, C. ;
Kops, E. Rota ;
Kaffanke, J. ;
Tellmann, L. ;
Scheins, J. ;
Neuner, I. ;
Stoffels, G. ;
Fischer, K. ;
Caldeira, L. ;
Coenen, H. H. ;
Shah, N. J. .
NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2011, 50 (02) :74-82
[14]   A prototype MR insertable brain PET using tileable GAPD arrays [J].
Hong, Key Jo ;
Choi, Yong ;
Jung, Jin Ho ;
Kang, Jihoon ;
Hu, Wei ;
Lim, Hyun Keong ;
Huh, Yoonsuk ;
Kim, Sangsu ;
Jung, Ji Woong ;
Kim, Kyu Bom ;
Song, Myung Sung ;
Park, Hyun-wook .
MEDICAL PHYSICS, 2013, 40 (04)
[15]  
Iborra A., 2017, P IEEE MED IM C
[16]   CASToR: a generic data organization and processing code framework for multi-modal and multi-dimensional tomographic reconstruction [J].
Merlin, Thibaut ;
Stute, Simon ;
Benoit, Didier ;
Bert, Julien ;
Carlier, Thomas ;
Comtat, Claude ;
Filipovic, Marina ;
Lamare, Frederic ;
Visvikis, Dimitris .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (18)
[17]   Performance characteristics of the MAMMOCARE PET system based on NEMA standard [J].
Moliner, L. ;
Correcher, C. ;
Hellingman, D. ;
Alamo, J. ;
Carrilero, V. ;
Orero, A. ;
Gonzalez, A. J. ;
Benlloch, J. M. .
JOURNAL OF INSTRUMENTATION, 2017, 12
[18]   Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET [J].
Moliner, L. ;
Correcher, C. ;
Gonzalez, A. J. ;
Conde, P. ;
Hernandez, L. ;
Orero, A. ;
Rodriguez-Alvarez, M. J. ;
Sanchez, F. ;
Soriano, A. ;
Vidal, L. F. ;
Benlloch, J. M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 :129-132
[19]   Feasibility of a brain-dedicated PET-MRI system using four-layer DOI detectors integrated with an RF head coil [J].
Nishikido, F. ;
Obata, T. ;
Shimizu, K. ;
Suga, M. ;
Inadama, N. ;
Tachibana, A. ;
Yoshida, E. ;
Ito, H. ;
Yamaya, T. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 756 :6-13
[20]   Development of 1.45-mm resolution four-layer DOI–PET detector for simultaneous measurement in 3T MRI [J].
Nishikido F. ;
Tachibana A. ;
Obata T. ;
Inadama N. ;
Yoshida E. ;
Suga M. ;
Murayama H. ;
Yamaya T. .
Radiological Physics and Technology, 2015, 8 (1) :111-119