Corneal Power Measurement Obtained by Fourier-Domain Optical Coherence Tomography: Repeatability, Reproducibility, and Comparison With Scheimpflug and Automated Keratometry Measurements

被引:22
|
作者
Wang, Qinmei [1 ,2 ,3 ]
Hua, Yanjun [1 ,2 ,3 ]
Savini, Giacomo [4 ]
Chen, Hao [1 ,2 ,3 ]
Bao, Fangjun [1 ,2 ]
Lin, Shishi [1 ,2 ]
Lu, Weicong [1 ,2 ]
Huang, Jinhai [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou 325027, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Hosp Eye, Wenzhou 325027, Zhejiang, Peoples R China
[3] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[4] GB Bietti Fdn IRCCS, Rome, Italy
关键词
corneal power; Scheimpflug; optical coherence tomography; precision; agreement; INTRAOCULAR-LENS POWER; LASER REFRACTIVE SURGERY; STATISTICAL-METHODS; PENTACAM; AGREEMENT; CAMERA; SYSTEM;
D O I
10.1097/ICO.0000000000000564
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To assess the repeatability and reproducibility of corneal power values obtained by a Fourier-domain optical coherence tomography (FD-OCT) system (RTVue) and to compare them with the values obtained by a Scheimpflug camera system (Pentacam HR) and by automated keratometry (IOL Master).Methods:Thirty-two eyes from 32 healthy subjects were included in this prospective study. Two experienced observers measured each eye 3 consecutive times with the Pentacam, IOLMaster, and RTVue centered on either the pupil or corneal vertex. The conventional keratometry equivalent (CKE) and anterior (K-a), posterior (K-p), and net (K-n) corneal power values were determined.Results:The corneal power values obtained by the RTVue showed high repeatability (all intraclass correlation coefficient >0.96) and reproducibility (coefficient of variation <1.0%). Pupil-centered FD-OCT performed slightly better than corneal vertex-centered FD-OCT. Mean corneal values had higher reproducibly than any of the individual values. CKE, K-a, K-p, and K-n obtained by FD-OCT were 0.62 to 0.68 diopters (D), 0.70 to 0.76 D, 0.11 to 0.13 D, and 0.93 to 0.94 D higher than those obtained by the Pentacam HR, respectively. CKE and K-a obtained with the RTVue were also 0.60 to 0.74 D higher than those obtained with the IOLMaster, respectively.Conclusions:The corneal power measurements obtained by the RTVue FD-OCT system showed high repeatability and reproducibility. Measurements obtained by FD-OCT with pupil centration were more reproducible than those obtained by FD-OCT with corneal vertex centration. We recommend that pupil-centered FD-OCT be used in clinical applications. Neither RTVue versus Pentacam HR nor RTVue versus IOLMaster can be used interchangeably.
引用
收藏
页码:1266 / 1271
页数:6
相关论文
共 50 条
  • [41] Comparison of the Optic Nerve Imaging by Time-Domain Optical Coherence Tomography and Fourier-Domain Optical Coherence Tomography in Distinguishing Normal Eyes From Those With Glaucoma
    Kim, Na Rae
    Kim, Ji Hyun
    Kim, Chan Yun
    Jun, Ikhyun
    Seong, Gong Je
    Lee, Eun Suk
    JOURNAL OF GLAUCOMA, 2013, 22 (01) : 36 - 43
  • [42] Interstudy reproducibility of the second generation, Fourier domain optical coherence tomography in patients with coronary artery disease and comparison with intravascular ultrasound: a study applying automated contour detection
    Jamil, Z.
    Tearney, G.
    Bruining, N.
    Sihan, K.
    van Soest, G.
    Ligthart, J.
    van Domburg, R.
    Bouma, B.
    Regar, E.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01) : 39 - 51
  • [43] Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement
    Kawamorita, Takushi
    Uozato, Hiroshi
    Kamiya, Kazutaka
    Bax, Leon
    Tsutsui, Kenta
    Aizawa, Daisuke
    Shimizu, Kimiya
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) : 127 - 133
  • [44] Dispersion manipulation in optical coherence tomography with Fourier-domain optical delay line
    Akcay, AC
    Lee, KS
    Rolland, JP
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 512 - 522
  • [45] Subtle Solar Retinopathy Detected by Fourier-domain Optical Coherence Tomography
    Kung, Ya-Hsin
    Wu, Tsung-Tien
    Sheu, Shwu-Jiuan
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2010, 73 (07) : 396 - 398
  • [46] Study of dual-source Fourier-domain optical coherence tomography
    Al-Saeed, Tarek A.
    Shalaby, Mohamed Y.
    Khalil, Diaa A.
    OPTICAL ENGINEERING, 2015, 54 (10)
  • [47] Comparative analysis of corneal measurements obtained from a Scheimpflug camera and an integrated Placido-optical coherence tomography device in normal and keratoconic eyes
    Viswanathan, Deepa
    Kumar, Nikhil L.
    Males, John J.
    Graham, Stuart L.
    ACTA OPHTHALMOLOGICA, 2015, 93 (06) : E488 - E494
  • [48] Repeatability of Pachymetry and Thinnest Point Localization Using a Fourier-Domain Optical Coherence Tomographer
    Keech, Adam
    Simpson, Trefford
    Jones, Lyndon
    OPTOMETRY AND VISION SCIENCE, 2010, 87 (10) : 736 - 741
  • [49] Repeatability and reproducibility of a new spectral-domain optical coherence tomography biometer and agreement with swept-source optical coherence tomography based biometer
    Li, Xin
    Lei, Chak Seng
    Ning, Rui
    Liu, Luze
    Chen, Aodong
    Yang, Xinning
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    EYE AND VISION, 2025, 12 (01)
  • [50] Comparison of Oculus Pentacam and Stratus Optical Coherence Tomography for Measurement of Central Corneal Thickness
    Ceylan, Osman Melih
    Turk, Adem
    Erdurman, Cuneyt
    Mumcuoglu, Tarkan
    Erdem, Uzeyir
    Gokce, Gokcen
    Dagli, Selim
    CORNEA, 2011, 30 (06) : 670 - 674