Corneal Power Measurement Obtained by Fourier-Domain Optical Coherence Tomography: Repeatability, Reproducibility, and Comparison With Scheimpflug and Automated Keratometry Measurements

被引:22
|
作者
Wang, Qinmei [1 ,2 ,3 ]
Hua, Yanjun [1 ,2 ,3 ]
Savini, Giacomo [4 ]
Chen, Hao [1 ,2 ,3 ]
Bao, Fangjun [1 ,2 ]
Lin, Shishi [1 ,2 ]
Lu, Weicong [1 ,2 ]
Huang, Jinhai [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou 325027, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Hosp Eye, Wenzhou 325027, Zhejiang, Peoples R China
[3] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[4] GB Bietti Fdn IRCCS, Rome, Italy
关键词
corneal power; Scheimpflug; optical coherence tomography; precision; agreement; INTRAOCULAR-LENS POWER; LASER REFRACTIVE SURGERY; STATISTICAL-METHODS; PENTACAM; AGREEMENT; CAMERA; SYSTEM;
D O I
10.1097/ICO.0000000000000564
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To assess the repeatability and reproducibility of corneal power values obtained by a Fourier-domain optical coherence tomography (FD-OCT) system (RTVue) and to compare them with the values obtained by a Scheimpflug camera system (Pentacam HR) and by automated keratometry (IOL Master).Methods:Thirty-two eyes from 32 healthy subjects were included in this prospective study. Two experienced observers measured each eye 3 consecutive times with the Pentacam, IOLMaster, and RTVue centered on either the pupil or corneal vertex. The conventional keratometry equivalent (CKE) and anterior (K-a), posterior (K-p), and net (K-n) corneal power values were determined.Results:The corneal power values obtained by the RTVue showed high repeatability (all intraclass correlation coefficient >0.96) and reproducibility (coefficient of variation <1.0%). Pupil-centered FD-OCT performed slightly better than corneal vertex-centered FD-OCT. Mean corneal values had higher reproducibly than any of the individual values. CKE, K-a, K-p, and K-n obtained by FD-OCT were 0.62 to 0.68 diopters (D), 0.70 to 0.76 D, 0.11 to 0.13 D, and 0.93 to 0.94 D higher than those obtained by the Pentacam HR, respectively. CKE and K-a obtained with the RTVue were also 0.60 to 0.74 D higher than those obtained with the IOLMaster, respectively.Conclusions:The corneal power measurements obtained by the RTVue FD-OCT system showed high repeatability and reproducibility. Measurements obtained by FD-OCT with pupil centration were more reproducible than those obtained by FD-OCT with corneal vertex centration. We recommend that pupil-centered FD-OCT be used in clinical applications. Neither RTVue versus Pentacam HR nor RTVue versus IOLMaster can be used interchangeably.
引用
收藏
页码:1266 / 1271
页数:6
相关论文
共 50 条
  • [31] Intraobserver repeatability and interobserver reproducibility of corneal measurements in normal eyes using an optical coherence tomography-Placido disk device
    Shah, Jinesh M.
    Han, Daphne
    Htoon, Hla Myint
    Mehta, Jodhbir S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02) : 372 - 381
  • [32] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Chak Seng Lei
    Xuanqiao Lin
    Rui Ning
    Jinjin Yu
    Xiaomin Huang
    Kexin Li
    Yiran Wang
    Giacomo Savini
    Domenico Schiano-Lomoriello
    Xingtao Zhou
    Jinhai Huang
    Ophthalmology and Therapy, 2023, 12 : 3263 - 3279
  • [33] Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device
    Bograd, Alexandra
    Himmel, Isabelle
    Pfister, Isabel B.
    Seiler, Theo G.
    Frueh, Beatrice E.
    Tappeiner, Christoph
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 262 (3) : 891 - 901
  • [34] Precision (Repeatability and Reproducibility) and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace
    Hua, Yanjun
    Xu, Zequan
    Qiu, Wei
    Wu, Qiang
    PLOS ONE, 2016, 11 (01):
  • [35] Repeatability, reproducibility, and agreement of corneal power measurements obtained with a new corneal topographer
    Mao, Xinjie
    Savini, Giacomo
    Zhuo, Zuopao
    Feng, Yifan
    Zhang, Jian
    Wang, Qinmei
    Chen, Hao
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (10) : 1561 - 1569
  • [36] Diffusion-sensitive Fourier-domain optical coherence tomography
    Hagen-Eggert, M.
    Hillmann, D.
    Koch, P.
    Huettmann, G.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [37] Comparison and Repeatability of Keratometric and Corneal Power Measurements Obtained by Orbscan II, Pentacam, and Galilei Corneal Tomography Systems
    Crawford, Alexandra Z.
    Patel, Dipika V.
    McGhee, Charles N. J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (01) : 53 - 60
  • [38] Full-field Fourier-domain optical coherence tomography
    Zvyagin, AV
    Blazkiewicz, P
    Vintrou, J
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 44 - 53
  • [39] MACULAR THICKNESS MEASUREMENTS IN NORMAL EYES WITH TIME-DOMAIN AND FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Huang, Jingjing
    Liu, Xing
    Wu, Ziqiang
    Xiao, Hui
    Dustin, Laurie
    Sadda, Srinivas
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (07): : 980 - 987
  • [40] Repeatability and Reproducibility of Retinal Thickness Measurements in Diabetic Patients with Spectral Domain Optical Coherence Tomography
    Fiore, Tito
    Androudi, Sofia
    Iaccheri, Barbara
    Lupidi, Marco
    Fabrizio, Giansanti
    Fruttini, Daniela
    Biondi, Laura
    Cagini, Carlo
    CURRENT EYE RESEARCH, 2013, 38 (06) : 674 - 679