Corneal Power Measurement Obtained by Fourier-Domain Optical Coherence Tomography: Repeatability, Reproducibility, and Comparison With Scheimpflug and Automated Keratometry Measurements

被引:22
|
作者
Wang, Qinmei [1 ,2 ,3 ]
Hua, Yanjun [1 ,2 ,3 ]
Savini, Giacomo [4 ]
Chen, Hao [1 ,2 ,3 ]
Bao, Fangjun [1 ,2 ]
Lin, Shishi [1 ,2 ]
Lu, Weicong [1 ,2 ]
Huang, Jinhai [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou 325027, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Hosp Eye, Wenzhou 325027, Zhejiang, Peoples R China
[3] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[4] GB Bietti Fdn IRCCS, Rome, Italy
关键词
corneal power; Scheimpflug; optical coherence tomography; precision; agreement; INTRAOCULAR-LENS POWER; LASER REFRACTIVE SURGERY; STATISTICAL-METHODS; PENTACAM; AGREEMENT; CAMERA; SYSTEM;
D O I
10.1097/ICO.0000000000000564
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To assess the repeatability and reproducibility of corneal power values obtained by a Fourier-domain optical coherence tomography (FD-OCT) system (RTVue) and to compare them with the values obtained by a Scheimpflug camera system (Pentacam HR) and by automated keratometry (IOL Master).Methods:Thirty-two eyes from 32 healthy subjects were included in this prospective study. Two experienced observers measured each eye 3 consecutive times with the Pentacam, IOLMaster, and RTVue centered on either the pupil or corneal vertex. The conventional keratometry equivalent (CKE) and anterior (K-a), posterior (K-p), and net (K-n) corneal power values were determined.Results:The corneal power values obtained by the RTVue showed high repeatability (all intraclass correlation coefficient >0.96) and reproducibility (coefficient of variation <1.0%). Pupil-centered FD-OCT performed slightly better than corneal vertex-centered FD-OCT. Mean corneal values had higher reproducibly than any of the individual values. CKE, K-a, K-p, and K-n obtained by FD-OCT were 0.62 to 0.68 diopters (D), 0.70 to 0.76 D, 0.11 to 0.13 D, and 0.93 to 0.94 D higher than those obtained by the Pentacam HR, respectively. CKE and K-a obtained with the RTVue were also 0.60 to 0.74 D higher than those obtained with the IOLMaster, respectively.Conclusions:The corneal power measurements obtained by the RTVue FD-OCT system showed high repeatability and reproducibility. Measurements obtained by FD-OCT with pupil centration were more reproducible than those obtained by FD-OCT with corneal vertex centration. We recommend that pupil-centered FD-OCT be used in clinical applications. Neither RTVue versus Pentacam HR nor RTVue versus IOLMaster can be used interchangeably.
引用
收藏
页码:1266 / 1271
页数:6
相关论文
共 50 条
  • [21] Repeatability of central corneal thickness measurements of donor corneas in preservation chamber using Fourier-domain anterior segment optical coherence tomography
    Abhinav Golla
    Li Wang
    Caleb Morris
    Mitchell P. Weikert
    Sumitra S. Khandelwal
    Cell and Tissue Banking, 2018, 19 : 717 - 720
  • [22] Reproducibility of Scheimpflug Tomography Measurements Regarding Corneal Front and Back Surface Power
    Stavridis, E.
    Eppig, T.
    Szentmary, N.
    Seitz, B.
    Langenbucher, A.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (11) : 1297 - 1303
  • [23] Corneal Tomography in a Commercially Available Optical Coherence Tomography Device and Comparison With a Rotating Scheimpflug Camera
    Kanclerz, Piotr
    Radomski, Szymon Adam
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (03): : 138 - 144
  • [24] In Vivo Comparison of Fourier-Domain Optical Coherence Tomography and Intravascular Ultrasonography
    Ramesh, Sathyadeepak
    Papayannis, Aristotelis
    Abdel-karim, Abdul-rahman
    Banerjee, Subhash
    Brilakis, Emmanouil
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (03) : 111 - 115
  • [25] Comparison of total keratometry with corneal power measured by optical low-coherence reflectometry and placido-dual Scheimpflug system
    Kommineni, Usha Bhanu
    Mohamed, Ashik
    Vaddavalli, Pravin K.
    Reddy, Jagadesh C.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (03) : 1496 - 1503
  • [26] Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature
    Zhang, Ting
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    CORNEA, 2020, 39 (07) : 818 - 822
  • [27] Limitations in imaging common conjunctival and corneal pathologies with Fourier-domain optical coherence tomography
    Demirci, Hakan
    Steen, Daniel W.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2014, 21 (03) : 220 - 224
  • [28] Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    PLOS ONE, 2021, 16 (05):
  • [29] Anterior chamber depth measurements using Scheimpflug imaging and optical coherence tomography: Repeatability, reproducibility, and agreement
    Wang, Qinmei
    Ding, Xixia
    Savini, Giacomo
    Chen, Hao
    Feng, Yifan
    Pan, Chao
    Hua, Yanjun
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01) : 178 - 185
  • [30] Contribution of Fourier-domain optical coherence tomography to the diagnosis of keratoconus progression
    Ouanezar, Sofiane
    Sandali, Otman
    Atia, Raphael
    Temstet, Cyrille
    Georgeon, Cristina
    Laroche, Laurent
    Borderie, Vincent
    Bouheraoua, Nacim
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (02) : 159 - 166