Quantitative dynamics of site-specific protein phosphorylation determined using liquid chromatography electrospray ionization mass spectrometry

被引:76
|
作者
Ruse, CI
Willard, B
Jin, JP
Haas, T
Kinter, M
Bond, M [1 ]
机构
[1] Case Western Reserve Univ, Sch Med, Dept Physiol & Biophys, Cleveland, OH 44106 USA
[2] Cleveland Clin Fdn, Lerner Res Inst, Dept Mol Cardiol, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Lerner Res Inst, Dept Cell Biol, Cleveland, OH 44195 USA
关键词
D O I
10.1021/ac0157122
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed and validated a method that uses liquid chromatography/electrospray ionization-mass spectrometry to quantify site-specific protein phosphorylation. The method uses selected ion monitoring to determine the chromatographic peak areas of specific tryptic peptides from the protein of interest. The extent of phosphorylation is determined from the ratio of the phosphopeptide peak area to the peak area of an unmodified reference peptide that acts as internal standard, correcting for variations in protein amounts and peptide recovery in the digest preparation procedure. As a result, we refer to this protocol as the native reference peptide method. Mole of phosphate at the selected site per mole of protein is obtained from this ratio, using calibration curves of synthetic peptides to determine relative responses. Our method begins with protein separation by SDS-PAGE and is carried out on amounts of peptide produced by an ingel digestion of single Coomassie blue-stained bands. To illustrate the utility of the method and provide validation, we used cardiac troponin I as analyte and monitored the time course of a protein kinase C fill reaction. Those analyses appropriately demonstrate the time-dependent increase of phosphorylation at a PKC-preferred site, Ser44 in the peptide (41)ISAS(p)R(45) and the concomitant consumption of the nonphosphorylated peptide. We believe that this method provides a novel tool to directly measure specific phosphorylation sites in proteins in different physiological states and expect that the method will be adaptable not only to a variety of samples types (i.e., culture cells, tissues, etc.) but to a variety of posttranslation modifications as well.
引用
收藏
页码:1658 / 1664
页数:7
相关论文
共 50 条
  • [1] Site-specific degree of phosphorylation in proteins measured by liquid chromatography-electrospray mass spectrometry
    Boehm, Martin E.
    Seidler, Joerg
    Hahn, Bettina
    Lehmann, Wolf D.
    PROTEOMICS, 2012, 12 (13) : 2167 - 2178
  • [2] Site-specific quantitation of protein nitration using liquid chromatography/tandem mass spectrometry
    Willard, BB
    Ruse, CI
    Keightley, JA
    Bond, M
    Kinter, M
    ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2370 - 2376
  • [3] Site-specific carbohydrate profiling of human transferrin by nano-flow liquid chromatography/electrospray ionization mass spectrometry
    Satomi, Y
    Shimonishi, Y
    Hase, T
    Takao, T
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (24) : 2983 - 2988
  • [4] Site-specific N-glycosylation analysis of human plasma ceruloplasmin using liquid chromatography with electrospray ionization tandem mass spectrometry
    Harazono, A
    Kawasaki, N
    Itoh, S
    Hashii, N
    Ishii-Watabe, A
    Kawanishi, T
    Hayakawa, T
    ANALYTICAL BIOCHEMISTRY, 2006, 348 (02) : 259 - 268
  • [5] Site-specific phosphorylation of human p53 protein determined by mass spectrometry
    Merrick, BA
    Zhou, W
    Martin, KJ
    Jeyarajah, S
    Parker, CE
    Selkirk, JK
    Tomer, KB
    Borchers, CH
    BIOCHEMISTRY, 2001, 40 (13) : 4053 - 4066
  • [6] Site-specific analysis of the N-glycans on murine polymeric immunoglobulin a using liquid chromatography electrospray mass spectrometry
    Kragten, EA
    Bergwerff, AA
    vanOostrum, J
    Muller, DR
    Richter, WJ
    JOURNAL OF MASS SPECTROMETRY, 1995, 30 (12): : 1679 - 1686
  • [7] Forensic toxicological determination of surfactant by liquid chromatography/electrospray ionization mass spectrometry and liquid chromatography/electrospray ionization tandem mass spectrometry
    Nishikawa, M
    Katagi, M
    Miki, A
    Tsuchihashi, H
    JOURNAL OF HEALTH SCIENCE, 2003, 49 (02) : 138 - 148
  • [8] Quantitative determination of saccharide surfactants in protein samples by liquid chromatography coupled to electrospray ionization mass spectrometry
    Deng, GJ
    Chow, D
    Sanyal, G
    ANALYTICAL BIOCHEMISTRY, 2001, 289 (02) : 124 - 129
  • [9] Site-specific deprotonation/sodiation of gramicidin S studied by electrospray ionization/mass spectrometry
    Hiraoka, Kenzo
    Akashi, Satoko
    Rankin-Turner, Stephanie
    Ninomiya, Satoshi
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2023, 493
  • [10] Structural determination and quantitative analysis of bacterial phospholipids using liquid chromatography electrospray ionization mass spectrometry
    Fang, JS