Effect of Epidural Infusion Bolus Delivery Rate on the Duration of Labor Analgesia: A Randomized Clinical Trial

被引:32
作者
Lange, Elizabeth M. S. [1 ]
Wong, Cynthia A. [3 ]
Fitzgerald, Paul C. [1 ]
Davila, Wilmer F. [1 ]
Rao, Suman [1 ]
McCarthy, Robert J. [1 ]
Toledo, Paloma [1 ,2 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Anesthesiol, 251 E Huron St F5-704, Chicago, IL 60611 USA
[2] Northwestern Univ, Feinberg Sch Med, Ctr Healthcare Studies, Chicago, IL 60611 USA
[3] Univ Iowa, Dept Anesthesia, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
关键词
INTERMITTENT; FENTANYL; MAINTENANCE; INJECTION; INTERVAL; VOLUME; TIME;
D O I
10.1097/ALN.0000000000002089
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Programmed intermittent boluses of local anesthetic have been shown to be superior to continuous infusions for maintenance of labor analgesia. High-rate epidural boluses increase delivery pressure at the catheter orifice and may improve drug distribution in the epidural space. We hypothesized that high-rate drug delivery would improve labor analgesia and reduce the requirement for provider-administered supplemental boluses for breakthrough pain. Methods: Nulliparous women with a singleton pregnancy at a cervical dilation of less than or equal to 5cm at request for neuraxial analgesia were eligible for this superiority-design, double-blind, randomized controlled trial. Neuraxial analgesia was initiated with intrathecal fentanyl 25 g. The maintenance epidural solution was bupivacaine 0.625mg/ml with fentanyl 1.95 g/ml. Programmed (every 60min) intermittent boluses (10ml) and patient controlled bolus (5ml bolus, lockout interval: 10min) were administered at a rate of 100ml/h (low-rate) or 300ml/h (high-rate). The primary outcome was percentage of patients requiring provider-administered supplemental bolus analgesia. Results: One hundred eight women were randomized to the low- and 102 to the high-rate group. Provider-administered supplemental bolus doses were requested by 44 of 108 (40.7%) in the low- and 37 of 102 (36.3%) in the high-rate group (difference -4.4%; 95% CI of the difference, -18.5 to 9.1%; P = 0.67). Patient requested/delivered epidural bolus ratio and the hourly bupivacaine consumption were not different between groups. No subject had an adverse event. Conclusions: Labor analgesia quality, assessed by need for provider- and patient-administered supplemental analgesia and hourly bupivacaine consumption was not improved by high-rate epidural bolus administration.
引用
收藏
页码:745 / 753
页数:9
相关论文
共 15 条
  • [1] Programmed Intermittent Epidural Bolus Versus Continuous Epidural Infusion for Labor Analgesia: The Effects on Maternal Motor Function and Labor Outcome. A Randomized Double-Blind Study in Nulliparous Women
    Capogna, Giorgio
    Camorcia, Michela
    Stirparo, Silvia
    Farcomeni, Alessio
    [J]. ANESTHESIA AND ANALGESIA, 2011, 113 (04) : 826 - 831
  • [2] Implementation of Programmed Intermittent Epidural Bolus for the Maintenance of Labor Analgesia
    Carvalho, Brendan
    George, Ronald B.
    Cobb, Benjamin
    McKenzie, Christine
    Riley, Edward T.
    [J]. ANESTHESIA AND ANALGESIA, 2016, 123 (04) : 965 - 971
  • [3] Chua SMH, 2004, CAN J ANAESTH, V51, P581, DOI 10.1007/BF03018402
  • [4] Intermittent vs continuous administration of epidural ropivacaine with fentanyl for analgesia during labour
    Fettes, P. D. W.
    Moore, C. S.
    Whiteside, J. B.
    Mcleod, G. A.
    Wildsmith, J. A. W.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2006, 97 (03) : 359 - 364
  • [5] Intermittent Epidural Bolus Compared with Continuous Epidural Infusions for Labor Analgesia: A Systematic Review and Meta-Analysis
    George, Ronald B.
    Allen, Terrence K.
    Habib, Ashraf S.
    [J]. ANESTHESIA AND ANALGESIA, 2013, 116 (01) : 133 - 144
  • [6] Harrell F., BLOCK RANDOMIZATION
  • [7] Distribution of solution in the epidural space: Examination by cryomicrotome section
    Hogan, Q
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 2002, 27 (02) : 150 - 156
  • [8] Programmed Intermittent Epidural Bolus for Labor Analgesia During First Stage of Labor: A Biased-Coin Up-and-Down Sequential Allocation Trial to Determine the Optimum Interval Time Between Boluses of a Fixed Volume of 10 mL of Bupivacaine 0.0625% With Fentanyl 2 μg/mL
    Kanczuk, Marcelo Epsztein
    Barrett, Nicholas Martin
    Arzola, Cristian
    Downey, Kristi
    Ye, Xiang Y.
    Carvalho, Jose C. A.
    [J]. ANESTHESIA AND ANALGESIA, 2017, 124 (02) : 537 - 541
  • [9] Epidural infusion: Continuous or bolus?
    Kaynar, AM
    Shankar, KB
    [J]. ANESTHESIA AND ANALGESIA, 1999, 89 (02) : 534 - 534
  • [10] An in vitro evaluation of the pressure generated during programmed intermittent epidural bolus injection at varying infusion delivery speeds
    Klumpner, Thomas T.
    Lange, Elizabeth M. S.
    Ahmed, Heena S.
    Fitzgerald, Paul C.
    Wong, Cynthia A.
    Toledo, Paloma
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2016, 34 : 632 - 637