Accuracy of Continuous Glucose Monitoring before, during, and after Aerobic and Anaerobic Exercise in Patients with Type 1 Diabetes Mellitus

被引:44
作者
Biagi, Lyvia [1 ,2 ]
Bertachi, Arthur [1 ,2 ]
Quiros, Carmen [3 ]
Gimenez, Marga [3 ,4 ]
Conget, Ignacio [3 ,4 ]
Bondia, Jorge [4 ,5 ]
Vehi, Josep [1 ,4 ]
机构
[1] Univ Girona, Inst Informat & Aplicac, Girona 17003, Spain
[2] Fed Univ Technol Parana UTFPR, BR-85053525 Guarapuava, Brazil
[3] IDIBAPS Inst Invest Biomed August Pi & Sunyer, Hosp Clin Univ, Endocrinol & Nutr Dept, Diabet Unit, Barcelona 08036, Spain
[4] Ctr Invest Biomed Red Diabet & Enfermedades Metab, Madrid 28029, Spain
[5] Univ Politecn Valencia, Inst Univ Automat & Informat Ind, E-46022 Valencia, Spain
来源
BIOSENSORS-BASEL | 2018年 / 8卷 / 01期
关键词
continuous glucose monitoring; accuracy; exercise; physical activity; type; 1; diabetes; GLYCEMIC CONTROL; SYSTEMS; ADULTS;
D O I
10.3390/bios8010022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes management as well as for CGM systems. In this work, the accuracy of CGM in the context of exercise is addressed. Six adults performed aerobic and anaerobic exercise sessions and used two Medtronic Paradigm Enlite-2 sensors under closed-loop therapy. CGM readings were compared with plasma glucose during different periods: one hour before exercise, during exercise, and four hours after the end of exercise. In aerobic sessions, the median absolute relative difference (MARD) increased from 9.5% before the beginning of exercise to 16.5% during exercise (p < 0.001), and then decreased to 9.3% in the first hour after the end of exercise (p < 0.001). For the anaerobic sessions, the MARD before exercise was 15.5% and increased without statistical significance to 16.8% during exercise realisation (p = 0.993), and then decreased to 12.7% in the first hour after the cessation of anaerobic activities (p = 0.095). Results indicate that CGM might present lower accuracy during aerobic exercise, but return to regular operation a few hours after exercise cessation. No significant impact for anaerobic exercise was found.
引用
收藏
页数:8
相关论文
共 15 条
[1]   Accuracy of continuous glucose monitoring during differing exercise conditions [J].
Bally, Lia ;
Zueger, Thomas ;
Pasi, Nicola ;
Carlos, Ciller ;
Paganini, Daniela ;
Stettler, Christoph .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 112 :1-5
[2]   Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections The DIAMOND Randomized Clinical Trial [J].
Beck, Roy W. ;
Riddlesworth, Tonya ;
Ruedy, Katrina ;
Ahmann, Andrew ;
Bergenstal, Richard ;
Haller, Stacie ;
Kollman, Craig ;
Kruger, Davida ;
McGill, Janet B. ;
Polonsky, William ;
Toschi, Elena ;
Wolpert, Howard ;
Price, David .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (04) :371-378
[3]  
Biagi Lyvia, 2017, J Diabetes Sci Technol, V11, P1089, DOI 10.1177/1932296817714272
[4]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[5]   Physical Activity/Exercise and Diabetes: A Position Statement of the American Diabetes Association [J].
Colberg, Sheri R. ;
Sigal, Ronald J. ;
Yardley, Jane E. ;
Riddell, Michael C. ;
Dunstan, David W. ;
Dempsey, Paddy C. ;
Horton, Edward S. ;
Castorino, Kristin ;
Tate, Deborah F. .
DIABETES CARE, 2016, 39 (11) :2065-2079
[6]   Closed- Loop Artificial Pancreas Systems: Engineering the Algorithms [J].
Doyle, Francis J., III ;
Huyett, Lauren M. ;
Lee, Joon Bok ;
Zisser, Howard C. ;
Dassau, Eyal .
DIABETES CARE, 2014, 37 (05) :1191-1197
[7]   Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes [J].
Garg, Satish K. ;
Weinzimer, Stuart A. ;
Tamborlane, William V. ;
Buckingham, Bruce A. ;
Bode, Bruce W. ;
Bailey, Timothy S. ;
Brazg, Ronald L. ;
Ilany, Jacob ;
Slover, Robert H. ;
Anderson, Stacey M. ;
Bergenstal, Richard M. ;
Grosman, Benyamin ;
Roy, Anirban ;
Cordero, Toni L. ;
Shin, John ;
Lee, Scott W. ;
Kaufman, Francine R. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (03) :155-163
[8]   Accuracy of two continuous glucose monitoring systems: a head-to-head comparison under clinical research centre and daily life conditions [J].
Kropff, J. ;
Bruttomesso, D. ;
Doll, W. ;
Farret, A. ;
Galasso, S. ;
Luijf, Y. M. ;
Mader, J. K. ;
Place, J. ;
Boscari, F. ;
Pieber, T. R. ;
Renard, E. ;
DeVries, J. H. .
DIABETES OBESITY & METABOLISM, 2015, 17 (04) :343-349
[9]   Accuracy of Continuous Glucose Monitoring During Exercise in Type 1 Diabetes Pregnancy [J].
Kumareswaran, Kavita ;
Elleri, Daniela ;
Allen, Janet M. ;
Caldwell, Karen ;
Nodale, Marianna ;
Wilinska, Malgorzata E. ;
Amiel, Stephanie A. ;
Hovorka, Roman ;
Murphy, Helen R. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (03) :223-229
[10]   Accuracy of Continuous Glucose Monitoring (CGM) during Continuous and High-Intensity Interval Exercise in Patients with Type 1 Diabetes Mellitus [J].
Moser, Othmar ;
Mader, Julia K. ;
Tschakert, Gerhard ;
Mueller, Alexander ;
Groeschl, Werner ;
Pieber, Thomas R. ;
Koehler, Gerd ;
Messerschmidt, Janin ;
Hofmann, Peter .
NUTRIENTS, 2016, 8 (08)