In vivo diffusion tensor MRI of the human heart: Reproducibility of breath-hold and navigator-based approaches

被引:131
作者
Nielles-Vallespin, Sonia [1 ,2 ]
Mekkaoui, Choukri [3 ]
Gatehouse, Peter [1 ,2 ]
Reese, Timothy G. [3 ]
Keegan, Jennifer [1 ,2 ]
Ferreira, Pedro F. [1 ,2 ]
Collins, Steve [1 ]
Speier, Peter [4 ]
Feiweier, Thorsten [4 ]
de Silva, Ranil [1 ,2 ]
Jackowski, Marcel P. [5 ]
Pennell, Dudley J. [1 ,2 ]
Sosnovik, David E. [3 ]
Firmin, David [1 ,2 ]
机构
[1] Royal Brompton & Harefield NHS Fdn Trust, Cardiovasc MR Unit, London, England
[2] Univ London Imperial Coll Sci Technol & Med, London SW7 2AZ, England
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Martinos Ctr Biomed Imaging, Boston, MA USA
[4] Siemens AG, Healthcare Sect, MR R&D, Erlangen, Germany
[5] Univ Sao Paulo, Inst Math & Stat, Sao Paulo, Brazil
基金
美国国家卫生研究院;
关键词
cardiovascular magnetic resonance imaging; prospective navigators; cardiac diffusion tensor imaging; cardiac diffusion-weighted imaging; RESONANCE CORONARY-ANGIOGRAPHY; CARDIAC FIBER ARCHITECTURE; MYOCARDIAL BLOOD-VOLUME; MAGNETIC-RESONANCE; HISTOLOGICAL VALIDATION; WATER DIFFUSION; LEFT-VENTRICLE; INFARCTION; MOTION; TRACTOGRAPHY;
D O I
10.1002/mrm.24488
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to implement a quantitative in vivo cardiac diffusion tensor imaging (DTI) technique that was robust, reproducible, and feasible to perform in patients with cardiovascular disease. A stimulated-echo single-shot echo-planar imaging (EPI) sequence with zonal excitation and parallel imaging was implemented, together with a novel modification of the prospective navigator (NAV) technique combined with a biofeedback mechanism. Ten volunteers were scanned on two different days, each time with both multiple breath-hold (MBH) and NAV multislice protocols. Fractional anisotropy (FA), mean diffusivity (MD), and helix angle (HA) fiber maps were created. Comparison of initial and repeat scans showed good reproducibility for both MBH and NAV techniques for FA (P > 0.22), MD (P > 0.15), and HA (P > 0.28). Comparison of MBH and NAV FA (FA(MBHday1) = 0.60 +/- 0.04, FA(NAVday1) = 0.60 +/- 0.03, P = 0.57) and MD (MDMBHday1 = 0.8 +/- 0.2 x 10(-3) mm(2)/s, MDNAVday1 = 0.9 +/- 0.2 x 10(-3) mm(2)/s, P = 0.07) values showed no significant differences, while HA values (HA(MBHday1Endo) = 22 +/- 10 degrees, HA(MBHday1Mid-Endo) = 20 +/- 6 degrees, HA(MBHday1Mid-Epi) = -1 +/- 6 degrees, HA(MBHday1Epi) = -17 +/- 6 degrees, HA(NAVday1Endo) = 7 +/- 7 degrees, HA(NAVday1Mid-Endo) = 13 +/- 8 degrees, HA(NAVday1Mid-Epi) = -2 +/- 7 degrees, HA(NAVday1Epi) = -14 +/- 6 degrees) were significantly different. The scan duration was 20% longer with the NAV approach. Currently, the MBH approach is the more robust in normal volunteers. While the NAV technique still requires resolution of some bulk motion sensitivity issues, these preliminary experiments show its potential for in vivo clinical cardiac diffusion tensor imaging and for delivering high-resolution in vivo 3D DTI tractography of the heart. Magn Reson Med 70:454-465, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:454 / 465
页数:12
相关论文
共 68 条
[1]  
Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
[2]  
2-O
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Remodeling of cardiac fiber structure after infarction in rats quantified with diffusion tensor MRI [J].
Chen, JJ ;
Song, SK ;
Liu, W ;
McLean, M ;
Allen, JS ;
Tan, J ;
Wickline, SA ;
Yu, X .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 285 (03) :H946-H954
[5]   Tracking neuronal fiber pathways in the living human brain [J].
Conturo, TE ;
Lori, NF ;
Cull, TS ;
Akbudak, E ;
Snyder, AZ ;
Shimony, JS ;
McKinstry, RC ;
Burton, H ;
Raichle, ME .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (18) :10422-10427
[6]   SMALL VESSEL AND TOTAL CORONARY BLOOD-VOLUME DURING INTRA-CORONARY ADENOSINE [J].
CRYSTAL, GJ ;
DOWNEY, HF ;
BASHOUR, FA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (02) :H194-H201
[7]   Prospective navigator correction of image position for coronary MR angiography [J].
Danias, PG ;
McConnell, MV ;
Khasgiwala, VC ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
RADIOLOGY, 1997, 203 (03) :733-736
[8]   Combined diffusion and strain MRI reveals structure and function of human myocardial laminar sheets in vivo [J].
Dou, JG ;
Tseng, WYI ;
Reese, TG ;
Wedeen, VJ .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :107-113
[9]   Cardiac diffusion MRI without motion effects [J].
Dou, JG ;
Reese, TG ;
Tseng, WYI ;
Wedeen, VJ .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :105-114
[10]   IN-VIVO MEASUREMENT OF WATER DIFFUSION IN THE HUMAN HEART [J].
EDELMAN, RR ;
GAA, JC ;
WEDEEN, VJ ;
LOH, E ;
HARE, JM ;
PRASAD, P ;
LI, W .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :423-428