SPECT imaging for radioaerosol deposition and clearance studies

被引:42
作者
Eberl, S
Chan, HK
Daviskas, E
机构
[1] Royal Prince Alfred Hosp, Dept PET & Nucl Med, Sydney, NSW, Australia
[2] Univ Sydney, Dept Pharm, Sydney, NSW 2006, Australia
[3] Royal Prince Alfred Hosp, Dept Resp Med, Sydney, NSW, Australia
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2006年 / 19卷 / 01期
关键词
aerosol deposition; aerosol clearance; lung; SPECT; radionuclide imaging;
D O I
10.1089/jam.2006.19.8
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Planar gamma camera scintigraphy is well established for measuring the deposition and clearance of radioaerosols. Single photon emission computed tomography (SPECT) provides three-dimensional (3D) reconstructions of the radioactivity distribution, thus avoiding the compression of 3D data into two-dimensional (2D) images and potentially offering superior assessment of aerosol deposition patterns. However, SPECT has traditionally been associated with long imaging times, making it unsuitable for measuring deposition and clearance of radioaerosols with fast clearance. Multi-detector SPECT systems can collect complete SPECT studies in <1 min, allowing both initial deposition and clearance over time to be assessed by dynamic SPECT. Simultaneous transmission measurement with an external source provides attenuation correction for absolute activity quantification as well as aiding in the definition of the lung volume of interest. A dynamic SPECT imaging protocol has been developed to allow fast imaging from the oropharynx to the abdomen using gamma cameras with limited axial field of views. This allows activity quantification not only in the lungs, but also in areas outside the thorax. However, fast dynamic SPECT imaging is technically and computationally more demanding and provides less scope for reducing the radioactivity administered to the subjects. It has been shown that dynamic SPECT, compared to planar imaging, is more sensitive in detecting changes in deposition as measured by the Penetration Index (PI). Thus, SPECT can better differentiate between large and small airways, which is important for lung regional analysis.
引用
收藏
页码:8 / 20
页数:13
相关论文
共 46 条
  • [1] Regional deposition and retention of particles in shallow, inhaled boluses: effect of lung volume
    Bennett, WD
    Scheuch, G
    Zeman, KL
    Brown, JS
    Kim, C
    Heyder, J
    Stahlhofen, W
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (01) : 168 - 173
  • [2] Regional distribution and kinetics of inhaled pharmaceuticals
    Berridge, MS
    Lee, ZH
    Heald, DL
    [J]. CURRENT PHARMACEUTICAL DESIGN, 2000, 6 (16) : 1631 - 1651
  • [3] In vitro and in vivo aspects of quantifying intrapulmonary deposition of a dry powder radioaerosol
    Bondesson, E
    Asking, L
    Borgström, L
    Nilsson, LE
    Trofast, E
    Wollmer, P
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 232 (1-2) : 149 - 156
  • [4] REGIONAL DEPOSITION OF NEBULIZED HYPODENSE NONISOTONIC SOLUTIONS IN THE HUMAN RESPIRATORY-TRACT
    CHAN, HK
    PHIPPS, PR
    GONDA, I
    COOK, P
    FULTON, R
    YOUNG, I
    BAUTOVICH, G
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (08) : 1483 - 1489
  • [5] Deposition of aqueous aerosol of technetium-99m diethylene triamine penta-acetic acid generated and delivered by a novel system (AERx) in healthy subjects
    Chan, HK
    Daviskas, E
    Eberl, S
    Robinson, M
    Bautovich, G
    Young, I
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (04) : 320 - 327
  • [6] Changes in lung deposition of aerosols due to hygroscopic growth: A fast SPECT study
    Chan, HK
    Eberl, S
    Daviskas, E
    Constable, C
    Young, I
    [J]. JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2002, 15 (03): : 307 - 311
  • [7] USE OF SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IN AEROSOL STUDIES
    CHAN, HK
    [J]. JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1993, 6 (01): : 23 - 36
  • [8] CHAN HK, 1999, J AEROSOL MED, V12, P135
  • [9] Aerosol deposition and clearance measurement: a novel technique using dynamic SPET
    Eberl, S
    Chan, HK
    Daviskas, E
    Constable, C
    Young, I
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (09) : 1365 - 1372
  • [10] Eberl S, 1996, J NUCL MED, V37, P137