Effects of orthoses on three-dimensional load-displacement properties of the cervical spine

被引:19
|
作者
Ivancic, Paul C. [1 ]
机构
[1] Yale Univ, Sch Med, Dept Orthopaed & Rehabil, Biomech Res Lab, New Haven, CT 06520 USA
关键词
Cervical collar; Cervicothoracic orthosis; Biomechanics; Spine; Motion; MOTION; IMMOBILIZATION; PRESSURE; EFFICACY; COLLARS; PATIENT; SYSTEM; VEST;
D O I
10.1007/s00586-012-2552-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Our objectives were to develop a skull-neck-thorax model capable of quantifying spinal motions in an intact human cadaver neck with and without cervical orthoses, determine the effect of orthoses on three-dimensional load-displacement properties of all cervical spinal levels, and compare and contrast our results with previously reported in vivo data. Load input flexibility tests were performed to evaluate two cervical collars (Vista(A (R)) collar and Vista(A (R)) Multipost collar) and two cervicothoracic orthoses (CTOs: Vista(A (R)) TS and Vista(A (R)) TS4) using the skull-neck-thorax model with 10 intact whole cervical spine specimens. The physiologic range of motion (RoM) limit was the peak obtained from flexibility tests with no orthosis. Pair-wise repeated measures, analysis of variance (p < 0.05), and Bonferroni post hoc tests determined significant differences in average peak RoM at each spinal level among the experimental conditions. Significant reductions below physiologic limits were observed due to all orthoses in: three-dimensional head/T1 RoMs, all sagittal intervertebral RoMs, and lateral bending at C4/5 through C7/T1. Both CTOs significantly reduced C6/7 sagittal RoM as compared to both collars. Intervertebral RoMs with the orthoses could not be differentiated from physiologic limits at the upper cervical spine in lateral bending and throughout the entire cervical spine in axial rotation, with the exception of C1/2. Our results indicate that cervical orthoses effectively immobilized the entire cervical spine in flexion/extension and the lower cervical spine in lateral bending. The CTOs improved immobilization of the lower cervical spine in flexion/extension as compared to the collars. The orthoses were least effective at restricting lateral bending of the upper spinal levels and axial rotation of all spinal levels, except C1/2. Understanding immobilization provided by orthoses will assist clinicians in selecting the most appropriate brace based upon patient-specific immobilization requirements.
引用
收藏
页码:169 / 177
页数:9
相关论文
共 50 条
  • [1] Effects of orthoses on three-dimensional load–displacement properties of the cervical spine
    Paul C. Ivancic
    European Spine Journal, 2013, 22 : 169 - 177
  • [2] Mechanical properties of the human cervical spine as shown by three-dimensional load-displacement curves
    Panjabi, MM
    Crisco, JJ
    Vasavada, A
    Oda, T
    Cholewicki, J
    Nibu, K
    Shin, E
    SPINE, 2001, 26 (24) : 2692 - 2700
  • [3] Load-displacement properties of the normal and injured lower cervical spine in vitro
    Richter, M
    Wilke, HJ
    Kluger, P
    Claes, L
    Puhl, W
    EUROPEAN SPINE JOURNAL, 2000, 9 (02) : 104 - 108
  • [4] Load-displacement properties of the normal and injured lower cervical spine in vitro
    M. Richter
    H-J. Wilke
    P. Kluger
    L. Claes
    W. Puhl
    European Spine Journal, 2000, 9 : 104 - 108
  • [5] 3-DIMENSIONAL LOAD-DISPLACEMENT CURVES DUE TO FORCES ON THE CERVICAL-SPINE
    PANJABI, MM
    SUMMERS, DJ
    PELKER, RR
    VIDEMAN, T
    FRIEDLAENDER, GE
    SOUTHWICK, WO
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1986, 4 (02) : 152 - 161
  • [6] MECHANICAL-PROPERTIES OF HUMAN THORACIC SPINE - SHOWN BY 3-DIMENSIONAL LOAD-DISPLACEMENT CURVES
    PANJABI, MM
    BRAND, RA
    WHITE, AA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (05): : 642 - 652
  • [7] Load-displacement properties of the thoracolumbar calf spine: Experimental results and comparison to known human data
    Wilke H.-J.
    Krischak S.T.
    Wenger K.H.
    Claes L.E.
    European Spine Journal, 1997, 6 (2) : 129 - 137
  • [8] THREE-DIMENSIONAL SEGMENTAL COUPLING RESPONSES OF THE CERVICAL SPINE
    Yoganandan, Narayan
    Stemper, Brian D.
    Pintar, Frank A.
    Paskoff, Glenn
    Shender, Barry
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 343 - 344
  • [9] LOAD DISPLACEMENT PROPERTIES OF LOWER CERVICAL-SPINE MOTION SEGMENTS
    MORONEY, SP
    SCHULTZ, AB
    MILLER, JAA
    ANDERSSON, GBJ
    JOURNAL OF BIOMECHANICS, 1988, 21 (09) : 769 - 779
  • [10] Intra-operative Determination of the Three Dimensional Load-displacement Behavior of Scoliotic Motion Segments
    Reutlinger, Christoph
    Gedet, Philippe
    Kowal, Jens
    Burger, Juergen
    Hasler, Carol
    Buecher, Philippe
    RESEARCH INTO SPINAL DEFORMITIES 7, 2010, 158 : 222 - +