Five-year Outcomes of Eyes With Glaucoma Drainage Device and Penetrating Keratoplasty

被引:40
作者
Knape, Robert M. [1 ]
Szymarek, Tiffany N. [1 ]
Tuli, Sonal S. [1 ]
Driebe, William T., Jr. [1 ]
Sherwood, Mark B. [1 ]
Smith, Mary Fran [1 ]
机构
[1] Univ Florida, Coll Med, Dept Ophthalmol, Gainesville, FL 32610 USA
关键词
penetrating keratoplasty; corneal transplant; graft failure; glaucoma drainage device; incisional glaucoma surgery; INTRAOCULAR-PRESSURE CONTROL; CORNEAL GRAFT-SURVIVAL; VALVE IMPLANT; CLINICAL-EXPERIENCE; BAERVELDT IMPLANT; MOLTENO IMPLANT; CILIARY SULCUS; RISK-FACTORS; TUBE SHUNT; TRANSPLANT;
D O I
10.1097/IJG.0b013e31821db3e5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate intraocular pressure (IOP) control and corneal graft survival rates in eyes with glaucoma drainage device (GDD) implantation and penetrating keratoplasty (PK) and 5 years of follow-up data. Design: Retrospective review. Methods: We performed a review of records of all patients who underwent both GDD placement and PK at our institution between January 1, 1988 and December 31, 2003. Twenty-eight eyes of 27 patients were studied. Glaucoma outcome was assessed by postoperative IOP, number of glaucoma medications, and need for further glaucoma surgery. Corneal grafts were assessed for clarity. Results: All eyes had GDD placement in the anterior chamber. The mean pre-GDD IOP was 28.8 +/- 10.3 mm Hg on a mean of 2.6 +/- 0.8 glaucoma medications. At 5-year follow-up, the mean IOP was 13.0 +/- 5.9 mm Hg on a mean of 0.9 +/- 1.0 glaucoma medications. GDD implantation successfully controlled glaucoma in 96%, 86%, 79%, 75%, and 71% of eyes at 1, 2, 3, 4, and 5 years, respectively. Grafts remained clear in 96%, 82%, 75%, 57%, and 54% of eyes at 1, 2, 3, 4, and 5 years, respectively. Failure of glaucoma outcome or graft survival was associated with prior intraocular surgeries. Conclusions: Our data suggests that GDD placement can provide glaucoma control in a high percentage (71%) of eyes with PK even at 5 years. Furthermore, the success of PK in eyes with GDD remains reasonable (54%) at 5 years. IOP control and graft survival rates are comparable with earlier published studies with shorter follow-up or tube placement in the vitreous cavity.
引用
收藏
页码:608 / 614
页数:7
相关论文
共 34 条
[1]   Graft survival and glaucoma outcome after simultaneous penetrating keratoplasty and Ahmed glaucoma valve implant [J].
Al-Torbak, A .
CORNEA, 2003, 22 (03) :194-197
[3]   Corneal transplant rejection rate and severity after endothelial keratoplasty [J].
Allan, Bruce D. S. ;
Terry, Mark A. ;
Price, Francis W., Jr. ;
Price, Marianne O. ;
Griffin, Neil B. ;
Claesson, Margareta .
CORNEA, 2007, 26 (09) :1039-1042
[4]   The long-term results of keratoplasty in eyes with a glaucoma drainage device [J].
Alvarenga, LS ;
Mannis, MJ ;
Brandt, JD ;
Lee, WB ;
Schwab, IR ;
Lim, MC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (02) :200-205
[5]   Corneal graft survival and intraocular pressure control after penetrating keratoplasty and glaucoma drainage device implantation [J].
Arroyave, CP ;
Scott, IU ;
Fantes, FE ;
Feuer, WJ ;
Murray, TG .
OPHTHALMOLOGY, 2001, 108 (11) :1978-1985
[6]   Penetrating keratoplasty and glaucoma [J].
Ayyala, RS .
SURVEY OF OPHTHALMOLOGY, 2000, 45 (02) :91-105
[7]   Management of patients with combined glaucoma and corneal transplant surgery [J].
Banitt, M. ;
Lee, R. K. .
EYE, 2009, 23 (10) :1972-1979
[8]  
Beebe W E, 1991, Refract Corneal Surg, V7, P67
[9]  
BEEBE WE, 1990, OPHTHALMOLOGY, V97, P1414
[10]   Clinical experience with the Ahmed glaucoma valve implant in eyes with prior or concurrent penetrating keratoplasties [J].
Coleman, AL ;
Mondino, BJ ;
Wilson, MR ;
Casey, R .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (01) :54-61