In vivo cartilage contact deformation in the healthy human tibiofemoral joint

被引:110
作者
Bingham, J. T. [1 ]
Papannagari, R. [1 ]
de Velde, S. K. Van [1 ]
Gross, C. [1 ]
Gill, T. J. [1 ]
Felson, D. T. [2 ]
Rubash, H. E. [1 ]
Li, G. [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Orthopaed Surg,Bioengn Lab, Boston, MA 02114 USA
[2] Boston Univ, Sch Med, Clin Epidemiol Unit, Boston, MA 02118 USA
基金
美国国家卫生研究院;
关键词
Compartmental cartilage deformation; Knee joint; Biomechanics; Magnetic resonance; Cartilage thickness;
D O I
10.1093/rheumatology/ken345
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. In vivo cartilage contact deformation is instrumental for understanding human joint function and degeneration. This study measured the total deformation of contacting articular cartilage in the human tibiofemoral joint during in vivo weight-bearing flexion. Methods. Eleven healthy knees were magnetic resonance (MR) scanned and imaged with a dual fluoroscopic system while the subject performed a weight-bearing single-leg lunge. The tibia, femur and associated articulating cartilage were constructed from the MR images and combined with the dual fluoroscopic images to determine in vivo cartilage contact deformation from full extension to 120 degrees of flexion. Results. In both compartments, minimum peak compartmental contact deformation occurred at 30 degrees of flexion (24 +/- 6% medial, 17 +/- 7% lateral) and maximum peak compartmental deformation occurred at 120 degrees of flexion (30 +/- 13% medial, 30 +/- 10% lateral) during the weight-bearing flexion from full extension to 120 degrees. Average medial contact areas and peak contact deformations were significantly greater than lateral compartment values (P < 0.05). In addition, cartilage thickness in regions of contact was on average 1.4- and 1.1-times thicker than the average thickness of the tibial and femoral cartilage surfaces, respectively (P < 0.05). Conclusions. These data may provide base- line knowledge for investigating the effects of various knee injuries on joint contact biomechanics and the aetiology of cartilage degeneration.
引用
收藏
页码:1622 / 1627
页数:6
相关论文
共 53 条
[1]   The distribution of cartilage thickness within the joints of the lower limb of elderly individuals [J].
Adam, C ;
Eckstein, F ;
Milz, S ;
Putz, R .
JOURNAL OF ANATOMY, 1998, 193 :203-214
[2]   In vivo serial joint space measurements during dynamic loading in a canine model of osteoarthritis [J].
Anderst, WJ ;
Les, C ;
Tashman, S .
OSTEOARTHRITIS AND CARTILAGE, 2005, 13 (09) :808-816
[3]   In vivo three-dimensional knee kinematics using a biplanar image-matching technique [J].
Asano, T ;
Akagi, M ;
Tanaka, K ;
Tamura, J ;
Nakamura, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) :157-166
[4]   QUANTITATION OF ARTICULAR SURFACE-TOPOGRAPHY AND CARTILAGE THICKNESS IN KNEE JOINTS USING STEREOPHOTOGRAMMETRY [J].
ATESHIAN, GA ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1991, 24 (08) :761-776
[5]   Patellofemoral joint contact area increases with knee flexion and weight-bearing [J].
Besier, TF ;
Draper, CE ;
Gold, GE ;
Beaupré, GS ;
Delp, SL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (02) :345-350
[6]   ARTICULAR CONTACT IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
KUIPER, JH ;
HUISKES, R ;
GROOTENBOER, HJ .
JOURNAL OF BIOMECHANICS, 1991, 24 (11) :1019-1031
[7]   3-D anatomically based dynamic modeling of the human knee to include tibio-femoral and patello-femoral joints [J].
Caruntu, DI ;
Hefzy, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01) :44-53
[8]   Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements [J].
Cohen, ZA ;
McCarthy, DM ;
Kwak, SD ;
Legrand, P ;
Fogarasi, F ;
Ciaccio, EJ ;
Ateshian, GA .
OSTEOARTHRITIS AND CARTILAGE, 1999, 7 (01) :95-109
[9]   AN INVITRO ANALYSIS OF PATELLOFEMORAL CONTACT AREAS AND PRESSURES FOLLOWING PROCUREMENT OF THE CENTRAL 1/3 PATELLAR TENDON [J].
DAGATA, SD ;
PEARSALL, AW ;
REIDER, B ;
DRAGANICH, LF .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (02) :212-219
[10]   In vivo tibiofemoral contact analysis using 3D MRI-based knee models [J].
DeFrate, LE ;
Sun, H ;
Gill, TJ ;
Rubash, HE ;
Li, GA .
JOURNAL OF BIOMECHANICS, 2004, 37 (10) :1499-1504