Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation

被引:3
|
作者
Hu, Chang-Lin [1 ,2 ]
Lin, Zhan-Sheng [3 ]
Chen, Yen-Yu [4 ]
Lin, Yuan-Hsiang [5 ]
Lai, Mei-Feng [3 ]
Li, Meng-Lin [2 ]
机构
[1] Ind Technol Res Inst, Biomed Technol & Device Res Labs, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst NanoEngn & MicroSyst, Hsinchu, Taiwan
[4] Stanford Univ, Sch Med, Ctr Cardiovasc Technol, Stanford, CA 94305 USA
[5] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Laser Doppler; flowmeter; microcirculation; blood pressure; peripheral arterial occlusive disease; edema; CUTANEOUS REACTIVE HYPEREMIA; FLOW;
D O I
10.3233/BME-2012-0724
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The laser Doppler flowmeter has become an effective tool for the clinical study of microcirculation with non-invasive measurements and excellent velocity resolution. Microcirculation flow measurements cannot be used as reference criteria for circulation function. Thus, the relative change in fingertip microcirculation was measured through inflation and deflation of an automatic sphygmomanometer wrapped around the arm, and the blood pressure and functional parameters of circulation, such as biological zero (BZ), peak flow (PF) and time to peak flow (t(p)), were determined. For 50 healthy participants, the correlation coefficients for the laser Doppler flowmeter and oscillometric results were 0.950 and 0.838 for systolic and diastolic pressure, respectively. The mean and standard errors for both methods fell within the range specified in the Association for the Advancement of Medical Instrumentation standards. The BZ of an edema patient was about 5 times higher than normal. For patients with peripheral arterial occlusive disease (PAOD), the PF could not be determined, and the tp was about twice the normal value. The accuracy of blood pressure measurements using the laser Doppler flowmeter was comparable to that of the commonly used oscillometric sphygmomanometer, and the physiological circulation functional parameters were useful in identifying signs of edema and PAOD.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [41] NONINVASIVE LASER-BASED BLOOD-PRESSURE MEASUREMENT IN RABBITS
    HERROLD, EM
    GOLDWEIT, RS
    CARTER, JN
    ZUCCOTTI, G
    BORER, JS
    AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (03) : 197 - 202
  • [42] The measurement of cutaneous blood flow in healthy volunteers subjected to physical exercise with ultrasound Doppler imaging and laser Doppler flowmetry
    Lenasi, Helena
    Potocnik, Nejka
    Petrishchev, Nikolaj
    Papp, Marina
    Egorkina, Anastasia
    Girina, Marina
    Skedina, Marina
    Kovaleva, Anna
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2017, 65 (04) : 373 - 381
  • [43] Development of a Wireless Sensor for the Measurement of Chicken Blood Flow Using the Laser Doppler Blood Flow Meter Technique
    Nishihara, Kei
    Iwasaki, Wataru
    Nakamura, Masaki
    Higurashi, Eiji
    Soh, Tomoki
    Itoh, Toshihiro
    Okada, Hironao
    Maeda, Ryutaro
    Sawada, Renshi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (06) : 1645 - 1653
  • [44] Signal processing methodology to study the cutaneous vasodilator response to a local external pressure application detected by laser Doppler flowmetry
    Humeau, A
    Fizanne, L
    Garry, A
    Saumet, JL
    L'Huillier, JP
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (01) : 190 - 192
  • [45] Optimizing finger systolic blood pressure measurements with laser Doppler: Validation of the second phalanx site
    Blaise, Sophie
    Constans, Joel
    Pellegrini, Laure
    Senet, Patricia
    Lazareth, Isabelle
    Cracowski, Jean-Luc
    Carpentier, Patrick
    MICROVASCULAR RESEARCH, 2020, 131
  • [46] Dynamic characteristics of the cutaneous vasodilator response to a local external pressure application detected by the laser Doppler flowmetry technique on anaesthetised rats
    Humeau, A
    Koitka, A
    Saument, JL
    L'Huillier, JP
    PHOTON MIGRATION AND DIFFUSE-LIGHT IMAGING, 2003, 5138 : 72 - 79
  • [47] Accuracy of Doppler blood pressure measurement in continuous-flow left ventricular assist device patients
    Li, Song
    Beckman, Jennifer A.
    Welch, Nathan G.
    Bjelkengren, Jason
    Masri, Sofia Carolina
    Minami, Elina
    Stempien-Otero, April
    Levy, Wayne C.
    O'Brien, Kevin D.
    Lin, Shin
    Farris, Stephen D.
    Chen, Richard K.
    Wood, Gregory
    Koomalsingh, Kevin
    Kirkpatrick, James
    McCabe, James
    Leary, Peter J.
    Chassagne, Fanette
    Chivukula, Venkat Keshav
    Aliseda, Alberto
    Mahr, Claudius
    ESC HEART FAILURE, 2019, 6 (04): : 793 - 798
  • [48] MEASUREMENT OF DIGITAL BLOOD-FLOW USING THE LASER DOPPLER, IMPEDANCE AND STRAIN-GAUGE METHODS
    YAMAMOTO, Y
    OBERG, PA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (02) : 113 - 118
  • [49] Laser Doppler Measurements of Systolic Blood Pressure on the First and Second Toe in Patients with Peripheral Arterial Disease
    Rosfors, Stefan
    Modin, Agnes
    Petrini, Johan
    INTERNATIONAL JOURNAL OF ANGIOLOGY, 2022, 31 (01) : 52 - 55
  • [50] Design and Implementation of Auscultation Blood Pressure Measurement using Vascular Transit Time and Physiological Parameters
    Hsiao, Chun-Chieh
    Horng, Joe
    Lee, Ren-Guey
    Lin, Robert
    2017 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2017, : 2996 - 3001