Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation

被引:3
|
作者
Hu, Chang-Lin [1 ,2 ]
Lin, Zhan-Sheng [3 ]
Chen, Yen-Yu [4 ]
Lin, Yuan-Hsiang [5 ]
Lai, Mei-Feng [3 ]
Li, Meng-Lin [2 ]
机构
[1] Ind Technol Res Inst, Biomed Technol & Device Res Labs, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst NanoEngn & MicroSyst, Hsinchu, Taiwan
[4] Stanford Univ, Sch Med, Ctr Cardiovasc Technol, Stanford, CA 94305 USA
[5] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Laser Doppler; flowmeter; microcirculation; blood pressure; peripheral arterial occlusive disease; edema; CUTANEOUS REACTIVE HYPEREMIA; FLOW;
D O I
10.3233/BME-2012-0724
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The laser Doppler flowmeter has become an effective tool for the clinical study of microcirculation with non-invasive measurements and excellent velocity resolution. Microcirculation flow measurements cannot be used as reference criteria for circulation function. Thus, the relative change in fingertip microcirculation was measured through inflation and deflation of an automatic sphygmomanometer wrapped around the arm, and the blood pressure and functional parameters of circulation, such as biological zero (BZ), peak flow (PF) and time to peak flow (t(p)), were determined. For 50 healthy participants, the correlation coefficients for the laser Doppler flowmeter and oscillometric results were 0.950 and 0.838 for systolic and diastolic pressure, respectively. The mean and standard errors for both methods fell within the range specified in the Association for the Advancement of Medical Instrumentation standards. The BZ of an edema patient was about 5 times higher than normal. For patients with peripheral arterial occlusive disease (PAOD), the PF could not be determined, and the tp was about twice the normal value. The accuracy of blood pressure measurements using the laser Doppler flowmeter was comparable to that of the commonly used oscillometric sphygmomanometer, and the physiological circulation functional parameters were useful in identifying signs of edema and PAOD.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [31] Detection of Site-Specific Blood Flow Variation in Humans during Running by a Wearable Laser Doppler Flowmeter
    Iwasaki, Wataru
    Nogami, Hirofumi
    Takeuchi, Satoshi
    Furue, Masutaka
    Higurashi, Eiji
    Sawada, Renshi
    SENSORS, 2015, 15 (10) : 25507 - 25519
  • [32] Noninvasive and nonocclusive determination of blood pressure using laser Doppler flowmetry
    Elter, P
    Stork, W
    Müller-Glaser, KD
    Lutter, N
    SPECIALTY FIBER OPTICS FOR MEDICAL APPLICATIONS, PROCEEDINGS OF, 1999, 3596 : 188 - 196
  • [33] Deterioration of Retinal Blood Flow Parameters in Branch Retinal Vein Occlusion Measured by Doppler Optical Coherence Tomography Flowmeter
    Takahashi, Kengo
    Song, Youngseok
    Sogawa, Kenji
    Yoshioka, Takafumi
    Tani, Tomofumi
    Ishiko, Satoshi
    Yoshida, Akitoshi
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (06) : 1 - 8
  • [34] Validity and application of noninvasive measurement of blood pressure in hamsters
    Kato, Y
    Iwase, M
    Kanazawa, H
    Nishizawa, T
    Zhao, YL
    Takagi, K
    Nagata, K
    Noda, A
    Koike, Y
    Yokota, M
    EXPERIMENTAL ANIMALS, 2003, 52 (04) : 359 - 363
  • [35] He-Ne laser effects on blood microcirculation during wound healing:: A method of in vivo study through laser Doppler flowmetry
    Núñez, SC
    Nogueira, GEC
    Ribeiro, MS
    Garcez, AS
    Lage-Marques, JL
    LASERS IN SURGERY AND MEDICINE, 2004, 35 (05) : 363 - 368
  • [36] Wearable Blood Flowmeter Appcessory with Low-Power Laser Doppler Signal Processing for Daily-Life Healthcare Monitoring
    Kuwabara, K.
    Higuchi, Y.
    Ogasawara, T.
    Koizumi, H.
    Haga, T.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6274 - 6277
  • [37] Application of a Neural Network to Improve the Automatic Measurement of Blood Pressure
    Salazar Mendiola, Juan Luis
    Vargas Luna, Jose Luis
    Gonzalez Guerra, Jose Luis
    Cortes Ramirez, Jorge Armando
    ENGINEERING APPLICATIONS OF NEURAL NETWORKS, EANN 2013, PT I, 2013, 383 : 263 - 272
  • [38] Practical Application of a New Cuffless Blood Pressure Measurement Method
    Gogiberidze, Nana
    Suvorov, Aleksandr
    Sultygova, Elizaveta
    Sagirova, Zhanna
    Kuznetsova, Natalia
    Gognieva, Daria
    Chomakhidze, Petr
    Frolov, Victor
    Bykova, Aleksandra
    Mesitskaya, Dinara
    Novikova, Alena
    Kondakov, Danila
    Volovchenko, Alexey
    Omboni, Stefano
    Kopylov, Philippe
    PATHOPHYSIOLOGY, 2023, 30 (04) : 586 - 598
  • [39] Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients
    Li, Song
    Beckman, Jennifer A.
    Welch, Nathan G.
    Cheng, Richard K.
    Rockom, Sunny W.
    Levy, Wayne C.
    O'Brien, Kevin D.
    Dardas, Todd F.
    Lin, Shin
    Leary, Peter J.
    Kirkpatrick, James
    McCabe, James M.
    Bjelkengren, Jason
    Chassagne, Fanette
    Aliseda, Alberto
    Zimpfer, Daniel
    Mahr, Claudius
    ESC HEART FAILURE, 2020, 7 (06): : 4241 - 4246
  • [40] Design and development of laser Doppler velocimetry based on DSP technique for blood flow measurement
    Lin, YH
    Chen, YY
    Ho, Y
    Li, YL
    Jan, GJ
    OPTICAL SENSING, IMAGING, AND MANIPULATION FOR BIOLOGICAL AND BIOMEDICAL APPLICATIONS, 2000, 4082 : 198 - 207