Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation

被引:3
|
作者
Hu, Chang-Lin [1 ,2 ]
Lin, Zhan-Sheng [3 ]
Chen, Yen-Yu [4 ]
Lin, Yuan-Hsiang [5 ]
Lai, Mei-Feng [3 ]
Li, Meng-Lin [2 ]
机构
[1] Ind Technol Res Inst, Biomed Technol & Device Res Labs, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst NanoEngn & MicroSyst, Hsinchu, Taiwan
[4] Stanford Univ, Sch Med, Ctr Cardiovasc Technol, Stanford, CA 94305 USA
[5] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Laser Doppler; flowmeter; microcirculation; blood pressure; peripheral arterial occlusive disease; edema; CUTANEOUS REACTIVE HYPEREMIA; FLOW;
D O I
10.3233/BME-2012-0724
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The laser Doppler flowmeter has become an effective tool for the clinical study of microcirculation with non-invasive measurements and excellent velocity resolution. Microcirculation flow measurements cannot be used as reference criteria for circulation function. Thus, the relative change in fingertip microcirculation was measured through inflation and deflation of an automatic sphygmomanometer wrapped around the arm, and the blood pressure and functional parameters of circulation, such as biological zero (BZ), peak flow (PF) and time to peak flow (t(p)), were determined. For 50 healthy participants, the correlation coefficients for the laser Doppler flowmeter and oscillometric results were 0.950 and 0.838 for systolic and diastolic pressure, respectively. The mean and standard errors for both methods fell within the range specified in the Association for the Advancement of Medical Instrumentation standards. The BZ of an edema patient was about 5 times higher than normal. For patients with peripheral arterial occlusive disease (PAOD), the PF could not be determined, and the tp was about twice the normal value. The accuracy of blood pressure measurements using the laser Doppler flowmeter was comparable to that of the commonly used oscillometric sphygmomanometer, and the physiological circulation functional parameters were useful in identifying signs of edema and PAOD.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [21] Low-power Consumption Integrated Laser Doppler Blood Flowmeter with a Built-in Silicon Microlens
    Kimura, Yoshinori
    Onoe, Atsushi
    Higurashi, Eiji
    Sawada, Renshi
    2008 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS, 2008, : 13 - +
  • [22] Laser Doppler blood flowmeter as a useful instrument for the early detection of lower extremity peripheral arterial disease in hemodialysis patients: an observational study
    Ishii, Takeo
    Takabe, Shizuka
    Yanagawa, Yuki
    Ohshima, Yuko
    Kagawa, Yasuhiro
    Shibata, Atsuko
    Oyama, Kunio
    BMC NEPHROLOGY, 2019, 20 (01)
  • [23] Functional Impairments of Microcirculation in HIV-Positive Patients: A Laser Doppler Fluxometry-Based Investigation
    Maggi, Paolo
    Bellacosa, Chiara
    Grattagliano, Vito
    Pastore, Giuseppe
    Lapadula, Giovanni
    HIV CLINICAL TRIALS, 2008, 9 (06): : 428 - 433
  • [24] Comparative Analysis of the Response of Microcirculation Parameters and Blood Pressure to Geomagnetic Activity in Healthy People
    Zenchenko, T. A.
    Rekhtina, A. G.
    Poskotinova, L. V.
    Zaslavskaya, R. M.
    Goncharov, L. F.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2012, 152 (04) : 402 - 405
  • [25] Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse
    Adair, HS
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS VIII, PROCEEDINGS OF, 1998, 3245 : 422 - 425
  • [26] Comparative Analysis of the Response of Microcirculation Parameters and Blood Pressure to Geomagnetic Activity in Healthy People
    T. A. Zenchenko
    A. G. Rekhtina
    L. V. Poskotinova
    R. M. Zaslavskaya
    L. F. Goncharov
    Bulletin of Experimental Biology and Medicine, 2012, 152 : 402 - 405
  • [27] Continuous Blood Pressure Monitoring Algorithm using Laser Doppler Flowmetry
    Kim, Insoo
    Hossain, Md Faruk
    Bhagat, Yusuf A.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3634 - 3637
  • [28] Measurement of Hemodynamics During Postural Changes Using a New Wearable Cephalic Laser Blood Flowmeter
    Fujikawa, Tetsuya
    Tochikubo, Osamu
    Kura, Naoki
    Kiyokura, Takanori
    Shimada, Junichi
    Umemura, Satoshi
    CIRCULATION JOURNAL, 2009, 73 (10) : 1950 - 1955
  • [29] Assessment of Blood Microcirculation Changes after COVID-19 Using Wearable Laser Doppler Flowmetry
    Zharkikh, Elena V.
    Loktionova, Yulia I.
    Fedorovich, Andrey A.
    Gorshkov, Alexander Y.
    Dunaev, Andrey V.
    DIAGNOSTICS, 2023, 13 (05)
  • [30] Improvement of the detection of human pulpal blood flow using a laser Doppler flowmeter modified for low flow velocity
    Qu, Xiaofu
    Ikawa, Motohide
    Shimauchi, Hidetoshi
    ARCHIVES OF ORAL BIOLOGY, 2014, 59 (02) : 199 - 206