Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation

被引:3
|
作者
Hu, Chang-Lin [1 ,2 ]
Lin, Zhan-Sheng [3 ]
Chen, Yen-Yu [4 ]
Lin, Yuan-Hsiang [5 ]
Lai, Mei-Feng [3 ]
Li, Meng-Lin [2 ]
机构
[1] Ind Technol Res Inst, Biomed Technol & Device Res Labs, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
[3] Natl Tsing Hua Univ, Inst NanoEngn & MicroSyst, Hsinchu, Taiwan
[4] Stanford Univ, Sch Med, Ctr Cardiovasc Technol, Stanford, CA 94305 USA
[5] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Laser Doppler; flowmeter; microcirculation; blood pressure; peripheral arterial occlusive disease; edema; CUTANEOUS REACTIVE HYPEREMIA; FLOW;
D O I
10.3233/BME-2012-0724
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The laser Doppler flowmeter has become an effective tool for the clinical study of microcirculation with non-invasive measurements and excellent velocity resolution. Microcirculation flow measurements cannot be used as reference criteria for circulation function. Thus, the relative change in fingertip microcirculation was measured through inflation and deflation of an automatic sphygmomanometer wrapped around the arm, and the blood pressure and functional parameters of circulation, such as biological zero (BZ), peak flow (PF) and time to peak flow (t(p)), were determined. For 50 healthy participants, the correlation coefficients for the laser Doppler flowmeter and oscillometric results were 0.950 and 0.838 for systolic and diastolic pressure, respectively. The mean and standard errors for both methods fell within the range specified in the Association for the Advancement of Medical Instrumentation standards. The BZ of an edema patient was about 5 times higher than normal. For patients with peripheral arterial occlusive disease (PAOD), the PF could not be determined, and the tp was about twice the normal value. The accuracy of blood pressure measurements using the laser Doppler flowmeter was comparable to that of the commonly used oscillometric sphygmomanometer, and the physiological circulation functional parameters were useful in identifying signs of edema and PAOD.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [1] Portable laser Doppler flowmeter for microcirculation detection
    Hu C.-L.
    Lin Z.-S.
    Chen Y.-Y.
    Lin Y.-H.
    Li M.-L.
    Biomedical Engineering Letters, 2013, 3 (2) : 109 - 114
  • [2] Evaluation of blood microcirculation parameters by combined use of laser Doppler flowmetry and videocapillaroscopy methods
    Volkov, M. V.
    Kostrova, D. A.
    Margaryants, N. B.
    Gurov, I. P.
    Erofeev, N. P.
    Dremin, V. V.
    Zharkikh, E. V.
    Zherebtsov, E. A.
    Kozlov, I. O.
    Dunaev, A. V.
    SARATOV FALL MEETING 2016 OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XVIII, 2017, 10336
  • [3] Laser reflectance oximetry and Doppler flowmetry in assessment of complex physiological parameters of cutaneous blood microcirculation
    Dunaev, Andrey V.
    Sidorov, Victor V.
    Stewart, Neil A.
    Sokolovski, Sergei G.
    Rafailov, Edik U.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS XI, 2013, 8572
  • [4] Interrelations of Hemorheological Parameters and Microcirculation in Subjects with an Increased Blood Pressure
    Muravyov A.V.
    Tikhomirova I.A.
    Mikhaylov P.V.
    Akhapkina A.A.
    Ostroumov R.S.
    Human Physiology, 2018, 44 (5) : 541 - 548
  • [5] Measurement of the skin microcirculation through intact bandages using laser Doppler flowmetry
    Melhuish, JM
    Krishnamoorthy, L
    Bethaves, T
    Clark, M
    Williams, RJ
    Harding, KG
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (02) : 259 - 263
  • [6] Measurement of the skin microcirculation through intact bandages using laser Doppler flowmetry
    J. M. Melhuish
    L. Krishnamoorthy
    T. Bethaves
    M. Clark
    R. J. Williams
    K. G. Harding
    Medical and Biological Engineering and Computing, 2004, 42 : 259 - 263
  • [7] MEASUREMENT OF FEMORAL-HEAD MICROCIRCULATION BY LASER DOPPLER FLOWMETRY
    BASSETT, GS
    APEL, DM
    WINTERSTEEN, VG
    TOLO, VT
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1991, 11 (03) : 307 - 313
  • [8] Integrated laser Doppler blood flowmeter combining optical contact force
    Nogami, Hirofumi
    Komatsutani, Kosuke
    Hirata, Tomoki
    Sawada, Renshi
    2019 INTERNATIONAL CONFERENCE ON ELECTRONICS PACKAGING (ICEP 2019), 2019, : 287 - 290
  • [9] Laser Doppler flux measurement for the assessment of cutaneous microcirculation - critical remarks
    Jung, F.
    Leithaeuser, B.
    Landgraf, H.
    Juenger, M.
    Franzeck, U.
    Pries, A.
    Sternitzky, R.
    Franke, R. P.
    Forconi, S.
    Ehrly, A. M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2013, 55 (04) : 411 - 416
  • [10] Verification and Calibration of Laser Doppler Flowmetry (LDF) Prototype for Measurement of Microcirculation
    Li, Yung-Hui
    Hu, Chia-Ming
    Tsai, Ming-Lun
    AOPC 2017: LASER COMPONENTS, SYSTEMS, AND APPLICATIONS, 2017, 10457