Neural control for voltage dips ride-through of oscillating water column-based wave energy converter equipped with doubly-fed induction generator

被引:35
作者
Alberdi, Mikel [1 ]
Amundarain, Modesto [1 ]
Garrido, Aitor [1 ]
Garrido, Izaskun [1 ]
机构
[1] Univ Basque Country, Dept Automat Control & Syst Engn, Bilbao 48012, Spain
关键词
Neural control; Doubly-fed induction generator; Low voltage ride through; Active crowbar; Wave energy; Wells turbine; WELLS TURBINE; PERFORMANCE; INTEGRATION; SIMULATION; SYSTEMS;
D O I
10.1016/j.renene.2012.04.014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The increasing penetration of renewable distributed power generation systems within electricity markets has given rise to new technical requirements. One of the most demanded skills is a fault-ride-through capability during voltage drops in the transmission system. This paper investigated the application of a neural control scheme to achieve the uninterrupted operation of oscillating water column-based wave energy converter equipped with doubly-fed induction generator during balanced grid faults. It is proposed an innovative solution consisting of a control scheme that suitably coordinates the air flow control, the active crowbar and the variable frequency converter, fulfilling the Spanish Grid Code. Besides, the variety of cases presented due to different sea states (amplitude and frequency) and characteristics of the grid fault (voltage drop and fault period), makes it necessary to adequately modify the references used by the controllers in order to achieve the desired fault-ride-through capability. In this sense, it has been implemented a neural control that adapts the controller references according to the pressure drop and voltage reduction, improving the controllability of the active and reactive power and the fault-ride-through capability during voltage drops. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:16 / 26
页数:11
相关论文
共 50 条
[41]   Modeling and parameter optimization of HTS-FCL based on low voltage ride-through of doubly-fed wind farm [J].
Song W. ;
Wang Q. ;
Li Y. ;
Wang X. ;
Zhou S. .
Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (18) :99-107
[42]   A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support [J].
沈阳武 ;
柯德平 ;
孙元章 ;
Daniel Kirschen ;
王轶申 ;
胡元朝 .
Chinese Physics B, 2015, (07) :54-65
[43]   A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support [J].
Shen Yang-Wu ;
Ke De-Ping ;
Sun Yuan-Zhang ;
Kirschen, Daniel ;
Wang Yi-Shen ;
Hu Yuan-Chao .
CHINESE PHYSICS B, 2015, 24 (07)
[44]   Analysis and Performance Evaluation for Transient Whole Process of Improved Control Strategy for Doubly-fed Induction Generator Crossed by High Voltage Ride Through [J].
Sun L. ;
Wang Y. .
Gaodianya Jishu/High Voltage Engineering, 2019, 45 (02) :593-599
[45]   Fault Ride-Through Operation Analysis of Doubly Fed Induction Generator-Based Wind Energy Conversion Systems: A Comparative Review [J].
Ansari, Aftab Ahmed ;
Dyanamina, Giribabu .
ENERGIES, 2022, 15 (21)
[46]   A low-voltage ride-through capability enhancement scheme of doubly fed induction generator based wind plant considering grid faults [J].
Gayen, P. K. ;
Chatterjee, D. ;
Goswami, S. K. .
JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2016, 8 (02)
[47]   Flexible power control for rotor-side converter of doubly-fed induction generator under unbalanced voltage condition [J].
Ma J. ;
Liu Q. ;
Wu J. ;
Sun F. ;
Wang Y. ;
Shen Y. ;
Zhou N. .
Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (02) :196-203
[48]   Control of a Variable-Impedance Fault Current Limiter to Assist Low-Voltage Ride-Through of Doubly Fed Induction Generators [J].
Huang, Jiejie ;
Sang, Shun ;
Zhang, Lei ;
Xue, Xiaocen ;
Sun, Tingting .
ELECTRONICS, 2021, 10 (19)
[49]   Coordinated Control Approaches for Low-Voltage Ride-Through Enhancement in Wind Turbines With Doubly Fed Induction Generators [J].
Rahimi, Mohsen ;
Parniani, Mostafa .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (03) :873-883
[50]   Fault Ride-through Strategy of Voltage-controlled Doubly-fed Wind Turbine Based on Improved Active Disturbance Rejection [J].
Xie Z. ;
Cui J. ;
Li Z. ;
Zhang X. .
Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (21) :160-169