Improved ultrasonic cleaning of membranes with tandem frequency excitation

被引:41
作者
Gonzalez-Avila, Silvestre Roberto [2 ]
Prabowo, Firdaus
Kumar, Anshuman [2 ]
Ohl, Claus-Dieter [1 ]
机构
[1] Nanyang Technol Univ, Sch Phys & Math Sci, Div Phys, Singapore 637371, Singapore
[2] Nanyang Technol Univ, Singapore 639798, Singapore
基金
新加坡国家研究基金会;
关键词
Ultrasound-cleaning; Membrane-fouling; High-speed video imaging; MICROFILTRATION MEMBRANES; FILTRATION; ENHANCEMENT; MECHANISMS; BUBBLES;
D O I
10.1016/j.memsci.2012.05.069
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In water purification membrane fouling is the most common problem that decresases efficiency in the purification process. In this work we propose a simple method to remove the particles deposited on the membrane surface by applying two different ultrasound frequencies in tandem. First a high ultrasound frequency, here 220 kHz, is used to create microscopic bubbles that are immediately after excited with a lower ultrasound frequency, e.g., 28 kHz. High speed video of the bare membrane shows the higher number of bubbles after the application of the high ultrasound frequency, as opposed to applying only a low ultrasound frequency. The method is then evaluated by recording the flux delivered and the transmembrane pressure (TMP) in this small scale experiment. The results show that after the application of the tandem frequency the transmembrane pressure is restored to the value of the non fouled membrane. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:776 / 783
页数:8
相关论文
共 29 条
[1]   The role of surface tension in stable single-bubble sonoluminescence [J].
Akhatov, I ;
Gumerov, N ;
Ohl, CD ;
Parlitz, U ;
Lauterborn, W .
PHYSICAL REVIEW LETTERS, 1997, 78 (02) :227-230
[2]  
[Anonymous], 2008, ADV MEMBRANE TECHNOL, DOI [DOI 10.1002/9780470276280.CH10, 10.1002/9780470276280.CH10]
[3]  
Brennen C.E., 1995, CAVITATION BUBBLE DY, P115
[4]   Ultrasound-associated cleaning of polymeric membranes for water treatment [J].
Chai, XJ ;
Kobayashi, T ;
Fujii, N .
SEPARATION AND PURIFICATION TECHNOLOGY, 1999, 15 (02) :139-146
[5]   Ultrasonic control of ceramic membrane fouling: Effect of particle characteristics [J].
Chen, D ;
Weavers, LK ;
Walker, HW .
WATER RESEARCH, 2006, 40 (04) :840-850
[6]   Motion of Micrometer Sized Spherical Particles Exposed to a Transient Radial Flow: Attraction, Repulsion, and Rotation [J].
Gonzalez-Avila, S. Roberto ;
Huang, Xiaohu ;
Quinto-Su, Pedro A. ;
Wu, Tom ;
Ohl, Claus-Dieter .
PHYSICAL REVIEW LETTERS, 2011, 107 (07)
[7]  
Gutman R.G., 1987, A HILGER
[8]   THEORY OF RECTIFIED DIFFUSION OF MASS INTO GAS BUBBLES [J].
HSIEH, DY ;
PLESSET, MS .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1961, 33 (02) :206-&
[9]   Use of submerged microfiltration membranes for glass industry wastewater reclamation: pilot-scale testing and membrane cleaning [J].
Kang, SK ;
Choo, KH .
DESALINATION, 2006, 189 (1-3) :170-180
[10]  
Kim W., 2009, APPL PHYS LETT, V081908, P94