A statistical analysis of an innovative concept of Trombe Wall by experimental tests

被引:8
|
作者
Szyszka, Jerzy [1 ]
Bevilaqua, Piero [2 ]
Bruno, Roberto [2 ]
机构
[1] Rzeszow Univ Technol, Fac Civil & Environm Engn & Architecture, PL-35959 Rzeszow, Poland
[2] Univ Calabria, Dept Mech Energet & Management Engn, I-87036 Cosenza, Italy
来源
JOURNAL OF BUILDING ENGINEERING | 2022年 / 62卷
关键词
Trombe wall; Design of experiments; Energy efficiency; Experimental analysis; THERMAL PERFORMANCE; BUILDINGS; BEHAVIOR; STORAGE; SYSTEM; BLIND;
D O I
10.1016/j.jobe.2022.105382
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Trombe Wall (TW) is one of the most effective passive heating systems that can be used in cold climates to provide solar gains to indoor environments. This study introduces an analyses of the effect of some boundary conditions on an innovative solution of the TW, named Thermo -Diode Trombe Wall (TDTW), which was designed to ensure significant thermal insulation for the building envelope and, at the same time, allows for exploiting solar gains rationally. Laboratory tests carried out in a climatic chamber setting proper indoor and outdoor tem-perature conditions allowed for calculating the thermal efficiency with reference to the absorbed solar radiation, simulated by a specific apparatus that permitted to vary the intensity and dura-tion of the thermal energy provided to the TDTW absorber. An experimental plan was defined according to the Design of Experiment (DoE) theory, setting 16 tests conducted varying the external air temperature, the absorbed energy and the time duration. The analysis allowed for obtaining the correlation between the thermal efficiency and the selected boundary conditions. Results showed how the thermal efficiency in the tests performed ranged between 21.58% and 30.30%. A statistical analysis allowed for determining the equation of the response surface that provides the efficiency as a function of the independent variables. Employing the nonlinear estimation method, results confirmed the adequacy of such an equation with a coefficient of determination R2 = 0.802 and a critical significance level p = 0.00016, much lower than the assumed 5% threshold.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] CFD Analysis for a New Trombe Wall Concept
    Bulmez, Alexandru Mihai
    Brezeanu, Alin Ionut
    Dragomir, George
    Fratu, Mariana
    Iordan, Nicolae Fani
    Bolocan, Sorin Ionut
    Rozorea, Lucian
    Popa, Eugen Calin
    Nastase, Gabriel
    BUILDINGS, 2024, 14 (03)
  • [2] Summer and winter performance of an innovative concept of Trombe wall for residential buildings
    Bevilacqua, Piero
    Bruno, Roberto
    Szyszka, Jerzy
    Cirone, Daniela
    Rollo, Antonino
    ENERGY, 2022, 258
  • [3] An Innovative Trombe Wall for Winter Use: The Thermo-Diode Trombe Wall
    Szyszka, Jerzy
    Bevilacqua, Piero
    Bruno, Roberto
    ENERGIES, 2020, 13 (09)
  • [4] Experimental analysis of a prototype for a thermochromic Trombe wall
    Martinez, Arturo
    Alonso, Carmen
    Martin-Consuegra, Fernando
    Perez, Gloria
    Frutos, Borja
    Gutierrez, Alvaro
    BUILDING RESEARCH AND INFORMATION, 2021, 49 (07): : 777 - 794
  • [5] Experimental analysis of a prototype for a thermochromic Trombe wall
    Martinez, Arturo
    Alonso, Carmen
    Martin-Consuegra, Fernando
    Perez, Gloria
    Frutos, Borja
    Gutierrez, Alvaro
    JOURNAL OF PLANNING LITERATURE, 2022, 37 (01) : 212 - 212
  • [6] An innovative Trombe wall with a solar concentrating function
    Dong, Xianzhang
    Xiao, Huigang
    Liu, Min
    Lin, Baochen
    Wang, Wei
    ENERGY AND BUILDINGS, 2024, 325
  • [7] An innovative Trombe wall as a passive heating system for a building in Athens-A comparison with the conventional Trombe wall and the insulated wall
    Bellos, Evangelos
    Tzivanidis, Christos
    Zisopoulou, Eleni
    Mitsopoulos, Georgios
    Antonopoulos, Kimon A.
    ENERGY AND BUILDINGS, 2016, 133 : 754 - 769
  • [8] Experimental and numerical performance analysis of a TC-Trombe wall
    Yu, Bendong
    He, Wei
    Li, Niansi
    Wang, Liping
    Cai, Jingyong
    Chen, Hongbing
    Ji, Jie
    Xu, Gang
    APPLIED ENERGY, 2017, 206 : 70 - 82
  • [9] Thermal analysis of a Trombe wall in various climatic conditions: An experimental study
    Mokni, Ameni
    Lashin, Ashraf
    Ammar, Marwa
    Mhiri, Hatem
    SOLAR ENERGY, 2022, 243 : 247 - 263
  • [10] ANALYTICAL AND EXPERIMENTAL INVESTIGATION OF THE TROMBE WALL.
    Casperson, Richard L.