Comparison of the Baska® mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery

被引:27
|
作者
Alexiev, V. [1 ,2 ]
Ochana, A. [1 ,2 ]
Abdelrahman, D. [1 ,2 ]
Coyne, J. [1 ,2 ]
McDonnell, J. G. [1 ,2 ]
O'Toole, D. P. [1 ,2 ]
Neligan, P. [1 ,2 ]
Laffey, J. G. [3 ,4 ]
机构
[1] Galway Univ Hosp, Dept Anaesthesia, Galway, Ireland
[2] Natl Univ Ireland, Galway, Ireland
[3] St Michaels Hosp, Dept Anesthesia, Toronto, ON M5B 1W8, Canada
[4] Univ Toronto, Toronto, ON, Canada
关键词
CERVICAL-SPINE IMMOBILIZATION; ANESTHETIZED ADULT PATIENTS; SUPRAGLOTTIC AIRWAY; TRACHEAL INTUBATION; I-GEL; MACINTOSH LARYNGOSCOPES; TRIAL; AIRWAYSCOPE(R); AIRTRAQ(R); MANAGEMENT;
D O I
10.1111/anae.12356
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We compared the Baska((R)) mask with the single-use classic laryngeal mask airway (cLMA) in 150 females at low risk for difficult tracheal intubation in a randomised, controlled clinical trial. We found that median (IQR [range]) seal pressure was significantly higher with the Baska mask compared with the cLMA (40 (34-40 [16-40]) vs 22 (18-25 [14-40])cmH(2)O, respectively, p<0.001), indicating a better seal. In contrast, the first time success rate for insertion of the Baska mask was lower than that seen with the cLMA (52/71 (73%) vs 77/99 (98%), respectively, p<0.001). There were no differences in overall device insertion success rates (78/79 (99%) vs 68/71 (96%), respectively, p=0.54). The Baska mask proved more difficult to insert, requiring more insertion attempts, taking longer to insert and had higher median (IQR [range]) insertion difficulty scores (1.6 (0.8-2.2 [0.1-5.6]) vs 0.5 (0.3-1.4 [0.1-4.0]), respectively, p<0.001). There was also an increased rate of minor blood staining of the Baska mask after removal, but there were no differences in other complication rates, such as laryngospasm, or in the severity of throat discomfort. In conclusion, in clinical situations where the seal with the glottic aperture takes priority over ease of insertion, the Baska mask may provide a useful alternative to the cLMA.
引用
收藏
页码:1026 / 1032
页数:7
相关论文
共 50 条
  • [31] Fastrach - a new intubating laryngeal mask airway: successful use in patients with difficult airways
    Joo, H
    Rose, K
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (03): : 253 - 256
  • [32] ProSeal versus Classic laryngeal mask airway (LMA) for positive pressure ventilation in adults undergoing elective surgery
    Hoda, Muhammad Qamarul
    Samad, Khalid
    Ullah, Hameed
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (07):
  • [33] Comparison of the laryngeal mask airway supreme and the i-gel in paralysed elderly patients A randomised controlled trial
    Kim, Myoung H.
    Lee, Jae H.
    Choi, Yong S.
    Park, Sujung
    Shin, Seokyung
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2018, 35 (08) : 598 - 604
  • [34] A randomized comparison of the i-gel and the ProSeal laryngeal mask airway in pediatric patients: performance and fiberoptic findings
    Fukuhara, Aya
    Okutani, Ryu
    Oda, Yutaka
    JOURNAL OF ANESTHESIA, 2013, 27 (01) : 1 - 6
  • [35] Comparison of the Effect of Laryngeal Mask Airway Versus Endotracheal Tube on Airway Management in Pediatric Patients with Tonsillar Hypertrophy
    Liu, Xiang
    Cao, Hongyan
    Tan, Xiaona
    Qiao, Li
    Zhang, Qi
    Shi, Lei
    JOURNAL OF PERIANESTHESIA NURSING, 2021, 36 (02) : 142 - 146
  • [36] Crossover Comparison of the Laryngeal Mask Supreme™ and the i-gel™ in Simulated Difficult Airway Scenario in Anesthetized Patients
    Theiler, Lorenz G.
    Kleine-Brueggeney, Maren
    Kaiser, Dagmar
    Urwyler, Natalie
    Luyet, Cedric
    Vogt, Andreas
    Greif, Robert
    Unibe, M. M. E.
    ANESTHESIOLOGY, 2009, 111 (01) : 55 - 62
  • [37] Instrumental and randomised clinical comparison between laryngeal mask airway Proseal and Supreme in pediatric patients
    Santambrogio, Luisa
    Righi, Sabrina
    Pinciroli, Rosa L.
    Piro, Eugenia
    D'alessio, Antonio
    Minuto, Aldo
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2020, 30 : 14 - 21
  • [38] Use of a modified ProSeal™ laryngeal mask airway to facilitate diagnostic fiberoptic bronchoscopy in anesthetized patients
    Xue, Fu-Shan
    He, Nong
    Xiang, Ping-Chao
    Liu, Jian-Hua
    Xu, Xiu Zheng
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2009, 56 (07): : 547 - 548
  • [39] Comparison of Outcome of Laryngeal Mask Airway (LMA Classic) and I-Gel Devices in Patients Undergoing General Anaesthesia in Elective Surgeries
    Dar, Shahid Rasool
    Hussain, Riaz
    Nazeer, Tahir
    Tahir, Amna
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (03): : 1036 - 1038
  • [40] Comparison of I-gel with Classic Laryngeal Mask Airway Regarding the Ease of Use and Clinical Performance
    Ari, Dilek Erdogan
    Ar, Arzu Yildirim
    Karip, Ceren Sanli
    Siyahkoc, Incifer
    Arslan, Ahmet Hakan
    Akgun, Fatma Nur
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (05) : 299 - 303